CPI BRC-1100 1:1 C-Band Redundant LNB System – CPI BRC redundant LNB system

CPI BRC-1100 1:1 C-Band Redundant LNB System

  • 3.40–4.20 GHz

Photo shows a representative model from this product line.

Price on request · quote-based pricing for government, teleport and enterprise buyers.

  • CAGE 6U0V1
  • GPC & purchase orders accepted
  • Engineering support from Melbourne, FL

Need it installed, integrated or supported? Ask about Digisat engineering services.

Product details

The CPI BRC-1100 is a 1:1 redundant LNB system from CPI's BRC-1000 Series for C-Band earth stations. It protects one receive chain: an online LNB and a hot spare share an outdoor switch plate at the antenna hub, and the indoor controller switches to the spare automatically if the online LNB fails.

The plate takes Norsat C-band PLL or externally referenced LNBs (5.15 GHz LO, 950–1750 MHz IF), ordered separately, on a CPR-229G waveguide input. Options include waveguide input isolators, Tx reject filters, 40 dB input crossguide couplers, offline LNB I/O ports, a remote control panel and ±48 VDC power.

Order the plate and controller as BRC-1100 and specify the Norsat C-band LNBs separately; Digisat can quote both together. The BRC-1000 Series comes in 2 listed models; compare them on the series page.

Other models in this series

Specifications

Part number BRC-1100
Series CPI BRC-1000
Input frequency 3.40–4.20 GHz
Output frequency 950–1750 MHz
LO frequency 5.15 GHz typ.
LNBs Norsat C-band PLL or externally referenced LNBs, ordered separately
External reference (externally referenced LNBs) 10 MHz, -5 to +5 dBm
Added system noise temperature (typ.) 7 K standard; add 1 K with couplers, 8 K with Tx reject filters, 14 K with waveguide isolators
Gain 59 dB min., 61 dB typ.
Gain flatness ±0.5 dB per 27 MHz
Gain stability ±0.2 dB max. per day at constant temperature; -0.05 dB per °C
Input VSWR 2.20:1 typ. without isolators; 1.25:1 typ., 1.30:1 max. with isolators; 1.30:1 typ., 1.35:1 max. with isolators and Tx filters
Output VSWR 1.50:1 typ., 2.00:1 max.
Output P1dB +2 dBm min. (+5 dBm typ.)
Output IP3 +12 dBm min. (+15 dBm typ.)
Frequency stability ±10 kHz, -40 °C to +60 °C
Phase noise (typ.) -55 / -75 / -85 / -95 dBc/Hz (100 Hz / 1 kHz / 10 kHz / 100 kHz)
Max. input power (no damage) 0 dBm
Desensitization threshold, Tx band -10 dBm max. without Tx filters; +45 dBm max. with Tx filters
RF input CPR-229G waveguide flange
RF output and offline out Type F female (75 Ω) or Type N female (50 Ω)
Offline in, coupler in Type N female (50 Ω)
Plate operating temperature -40 °C to +60 °C
Controller 1RU, 19 in rack mount; dual redundant power supplies; universal AC input
Controller M&C 10/100Base-T Ethernet (SNMP v1/v2c/v3), RS-232/422/485 serial, parallel I/O

CPI notes that commercial C-band LNBs may measure up to 10 K above their stated noise temperature, so system noise depends on the LNBs fitted.

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.