CPI BRC-1000 Series C-Band Redundant LNB System

CPI's BRC-1000 Series protects a C-band earth station against LNB failure. Each system is an outdoor plate assembly that mounts at the antenna hub, with waveguide/coax transfer switches for Norsat C-band PLL or externally referenced LNBs, plus a 1RU indoor redundancy controller and the control cable between them. A 1:1 system protects one receive chain; a 1:2 system protects two chains, typically both polarizations, with one shared spare. The LNBs are ordered separately by model number, and Digisat stocks the matching Norsat C-band LNBs.

Key features

  • Plate for Norsat C-band PLL or externally referenced LNBs (ordered separately)
  • 3.40–4.20 GHz input, 950–1750 MHz output, 5.15 GHz LO
  • Outdoor plate assembly with dual waveguide/coax transfer switches, manual override and waveguide input flanges
  • 1RU, 19 in rack-mount redundancy controller with dual redundant power supplies and universal AC input
  • Automatic or manual switchover; the controller monitors unit current, external alarms or both
  • 10/100Base-T Ethernet with SNMP v1, v2c and v3, plus RS-232/422/485 serial and parallel I/O M&C
  • Front panel shows switch positions and unit status; audible alarm; CE certified and RoHS compliant
  • Options: waveguide input isolators, Tx reject filters, 40 dB input crossguide couplers, offline LNB I/O ports, ±48 VDC power
  • Control cable up to 500 ft (150 m) in 50 ft steps; remote control panel up to 4000 ft (1200 m) away

CPI BRC-1000 Series C-Band Redundant LNB System products

Skip to results list

Active filters:

2 items
Column grid
Column grid

Filter

Active filters:

  • CPI BRC-1100 1:1 C-Band Redundant LNB System, 3.40–4.20 GHz

    CPI BRC-1100 1:1 C-Band Redundant LNB System, 3.40–4.20 GHz

    View specs & quote
  • CPI BRC-1200 1:2 C-Band Redundant LNB System, 3.40–4.20 GHz

    CPI BRC-1200 1:2 C-Band Redundant LNB System, 3.40–4.20 GHz

    View specs & quote

All 2 models

Part numberConfiguration
BRC-11001:1
BRC-12001:2

Specifications

Input frequency3.40–4.20 GHz
Output frequency950–1750 MHz
LO frequency5.15 GHz typ.
LNBsNorsat C-band PLL or externally referenced LNBs, ordered separately
External reference (externally referenced LNBs)10 MHz, -5 to +5 dBm
Gain59 dB min., 61 dB typ.
Gain flatness±0.5 dB per 27 MHz
Gain stability±0.2 dB max. per day at constant temperature; -0.05 dB per °C
Input VSWR2.20:1 typ. without isolators; 1.25:1 typ., 1.30:1 max. with isolators; 1.30:1 typ., 1.35:1 max. with isolators and Tx filters
Output VSWR1.50:1 typ., 2.00:1 max.
Output P1dB+2 dBm min. (+5 dBm typ.)
Output IP3+12 dBm min. (+15 dBm typ.)
Frequency stability±10 kHz, -40 °C to +60 °C
Phase noise (typ.)-55 / -75 / -85 / -95 dBc/Hz (100 Hz / 1 kHz / 10 kHz / 100 kHz)
Max. input power (no damage)0 dBm
Desensitization threshold, Tx band-10 dBm max. without Tx filters; +45 dBm max. with Tx filters
RF inputCPR-229G waveguide flange
RF output and offline outType F female (75 Ω) or Type N female (50 Ω)
Offline in, coupler inType N female (50 Ω)
Plate operating temperature-40 °C to +60 °C
Controller1RU, 19 in rack mount; dual redundant power supplies; universal AC input
Controller M&C10/100Base-T Ethernet (SNMP v1/v2c/v3), RS-232/422/485 serial, parallel I/O

CPI notes that commercial C-band LNBs may measure up to 10 K above their stated noise temperature, so system noise depends on the LNBs fitted.

Applications

  • C-band teleports and broadcast receive sites that can't tolerate outages
  • Dual-polarization receive chains protected by one spare (1:2)
  • Earth stations monitored over SNMP

Frequently asked questions

What is the difference between a 1:1 and a 1:2 system?

A 1:1 system protects one receive chain with one spare. A 1:2 system protects two chains, usually the two polarizations of a dual-pol feed, with a single shared spare, so it needs one less amplifier than two separate 1:1 systems.

Can Digisat install and commission the system?

Yes. Digisat engineers mount redundant LNA and LNB plates at the antenna hub, run and terminate the control cable, set up the controller and its SNMP monitoring, and test switchover before handover. Ask for installation when you request a quote.

Which LNBs go in the plate?

CPI builds the BRC-1000 around Norsat C-band PLL or externally referenced LNBs, ordered separately by model number. Use a 5.15 GHz LO model for the 3.40–4.20 GHz plan shown here. Digisat carries the full Norsat C-band LNB range and can quote the plate and LNBs together.

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.