CPI BRC-1100 1:1 C-Band Redundant LNB System
- 3.40–4.20 GHz
Photo shows a representative model from this product line.
Price on request · quote-based pricing for government, teleport and enterprise buyers.
- CAGE 6U0V1
- GPC & purchase orders accepted
- Engineering support from Melbourne, FL
Need it installed, integrated or supported? Ask about Digisat engineering services.
Product details
The CPI BRC-1100 is a 1:1 redundant LNB system from CPI's BRC-1000 Series for C-Band earth stations. It protects one receive chain: an online LNB and a hot spare share an outdoor switch plate at the antenna hub, and the indoor controller switches to the spare automatically if the online LNB fails.
The plate takes Norsat C-band PLL or externally referenced LNBs (5.15 GHz LO, 950–1750 MHz IF), ordered separately, on a CPR-229G waveguide input. Options include waveguide input isolators, Tx reject filters, 40 dB input crossguide couplers, offline LNB I/O ports, a remote control panel and ±48 VDC power.
Order the plate and controller as BRC-1100 and specify the Norsat C-band LNBs separately; Digisat can quote both together. The BRC-1000 Series comes in 2 listed models; compare them on the series page.
Other models in this series
Specifications
| Part number | BRC-1100 |
|---|---|
| Series | CPI BRC-1000 |
| Input frequency | 3.40–4.20 GHz |
| Output frequency | 950–1750 MHz |
| LO frequency | 5.15 GHz typ. |
| LNBs | Norsat C-band PLL or externally referenced LNBs, ordered separately |
| External reference (externally referenced LNBs) | 10 MHz, -5 to +5 dBm |
| Added system noise temperature (typ.) | 7 K standard; add 1 K with couplers, 8 K with Tx reject filters, 14 K with waveguide isolators |
| Gain | 59 dB min., 61 dB typ. |
| Gain flatness | ±0.5 dB per 27 MHz |
| Gain stability | ±0.2 dB max. per day at constant temperature; -0.05 dB per °C |
| Input VSWR | 2.20:1 typ. without isolators; 1.25:1 typ., 1.30:1 max. with isolators; 1.30:1 typ., 1.35:1 max. with isolators and Tx filters |
| Output VSWR | 1.50:1 typ., 2.00:1 max. |
| Output P1dB | +2 dBm min. (+5 dBm typ.) |
| Output IP3 | +12 dBm min. (+15 dBm typ.) |
| Frequency stability | ±10 kHz, -40 °C to +60 °C |
| Phase noise (typ.) | -55 / -75 / -85 / -95 dBc/Hz (100 Hz / 1 kHz / 10 kHz / 100 kHz) |
| Max. input power (no damage) | 0 dBm |
| Desensitization threshold, Tx band | -10 dBm max. without Tx filters; +45 dBm max. with Tx filters |
| RF input | CPR-229G waveguide flange |
| RF output and offline out | Type F female (75 Ω) or Type N female (50 Ω) |
| Offline in, coupler in | Type N female (50 Ω) |
| Plate operating temperature | -40 °C to +60 °C |
| Controller | 1RU, 19 in rack mount; dual redundant power supplies; universal AC input |
| Controller M&C | 10/100Base-T Ethernet (SNMP v1/v2c/v3), RS-232/422/485 serial, parallel I/O |
CPI notes that commercial C-band LNBs may measure up to 10 K above their stated noise temperature, so system noise depends on the LNBs fitted.
Need it installed, aligned or supported?
Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.