Norsat MEDIAN 100W X-Band GaAs BUC
- 7.900–8.400 GHz
Price on request · quote-based pricing for government, teleport and enterprise buyers.
- CAGE 6U0V1
- GPC & purchase orders accepted
- Engineering support from Melbourne, FL
Need it installed, integrated or supported? Ask about Digisat engineering services.
Product details
The Norsat MEDIAN 100W X-Band GaAs BUC is a high-performance GaAs block upconverter from Norsat's MEDIAN line, delivering 100W of rated output power (+50 dBm minimum P1dB) across 7.900–8.400 GHz. It's built for teleports, gateways, broadcast uplinks and military terminals, with configurations for AC or DC power and internal or external frequency reference. All 72 orderable part numbers are listed below; tell us your requirements and we'll confirm the exact configuration.
Key features
- 100W rated output; +50 dBm minimum P1dB
- Transmit band: 7.900–8.400 GHz
- L-band IF input: 950–1450 MHz
- Power: 100-240V AC and 42-60V DC
- Monitor and control: Cyber Hardened and Standard M&C
- CPR-112G RF output; IP65+; rated −40 to +55 °C
- Weight: 14.9 kg and 14.5 kg; 3-year warranty
Configuration options
| Input connector | TNC (50 Ω) · Type-N (50 Ω) · F-type (75 Ω) |
|---|---|
| M&C Option | Cyber Hardened · Standard M&C |
| Gain Version | Standard Gain · WGS Compatibility Option |
| Configuration | AC + EXT Ref · AC + INT Ref High Stability · AC + INT Ref Standard Stability · DC + EXT Ref · DC + INT Ref High Stability · DC + INT Ref Standard Stability |
All 72 part numbers
| Part number | Input connector | M&C Option | Gain Version | Configuration |
|---|---|---|---|---|
| MEDIBX100AH-XF-C | F-type (75 Ω) | Cyber Hardened | Standard Gain | AC + INT Ref Standard Stability |
| MEDIBX100AH-XF-CW | F-type (75 Ω) | Cyber Hardened | WGS Compatibility Option | AC + INT Ref Standard Stability |
| MEDIBX100AH-XF-S | F-type (75 Ω) | Standard M&C | Standard Gain | AC + INT Ref Standard Stability |
| MEDIBX100AH-XF-SW | F-type (75 Ω) | Standard M&C | WGS Compatibility Option | AC + INT Ref Standard Stability |
| MEDIBX100AH-XN-C | Type-N (50 Ω) | Cyber Hardened | Standard Gain | AC + INT Ref Standard Stability |
| MEDIBX100AH-XN-CW | Type-N (50 Ω) | Cyber Hardened | WGS Compatibility Option | AC + INT Ref Standard Stability |
| MEDIBX100AH-XN-S | Type-N (50 Ω) | Standard M&C | Standard Gain | AC + INT Ref Standard Stability |
| MEDIBX100AH-XN-SW | Type-N (50 Ω) | Standard M&C | WGS Compatibility Option | AC + INT Ref Standard Stability |
| MEDIBX100AH-XT-C | TNC (50 Ω) | Cyber Hardened | Standard Gain | AC + INT Ref Standard Stability |
| MEDIBX100AH-XT-CW | TNC (50 Ω) | Cyber Hardened | WGS Compatibility Option | AC + INT Ref Standard Stability |
| MEDIBX100AH-XT-S | TNC (50 Ω) | Standard M&C | Standard Gain | AC + INT Ref Standard Stability |
| MEDIBX100AH-XT-SW | TNC (50 Ω) | Standard M&C | WGS Compatibility Option | AC + INT Ref Standard Stability |
| MEDIBX100AS-XF-C | F-type (75 Ω) | Cyber Hardened | Standard Gain | AC + INT Ref High Stability |
| MEDIBX100AS-XF-CW | F-type (75 Ω) | Cyber Hardened | WGS Compatibility Option | AC + INT Ref High Stability |
| MEDIBX100AS-XF-S | F-type (75 Ω) | Standard M&C | Standard Gain | AC + INT Ref High Stability |
| MEDIBX100AS-XF-SW | F-type (75 Ω) | Standard M&C | WGS Compatibility Option | AC + INT Ref High Stability |
| MEDIBX100AS-XN-C | Type-N (50 Ω) | Cyber Hardened | Standard Gain | AC + INT Ref High Stability |
| MEDIBX100AS-XN-CW | Type-N (50 Ω) | Cyber Hardened | WGS Compatibility Option | AC + INT Ref High Stability |
| MEDIBX100AS-XN-S | Type-N (50 Ω) | Standard M&C | Standard Gain | AC + INT Ref High Stability |
| MEDIBX100AS-XN-SW | Type-N (50 Ω) | Standard M&C | WGS Compatibility Option | AC + INT Ref High Stability |
| MEDIBX100AS-XT-C | TNC (50 Ω) | Cyber Hardened | Standard Gain | AC + INT Ref High Stability |
| MEDIBX100AS-XT-CW | TNC (50 Ω) | Cyber Hardened | WGS Compatibility Option | AC + INT Ref High Stability |
| MEDIBX100AS-XT-S | TNC (50 Ω) | Standard M&C | Standard Gain | AC + INT Ref High Stability |
| MEDIBX100AS-XT-SW | TNC (50 Ω) | Standard M&C | WGS Compatibility Option | AC + INT Ref High Stability |
| MEDIBX100A-XF-C | F-type (75 Ω) | Cyber Hardened | Standard Gain | AC + EXT Ref |
| MEDIBX100A-XF-CW | F-type (75 Ω) | Cyber Hardened | WGS Compatibility Option | AC + EXT Ref |
| MEDIBX100A-XF-S | F-type (75 Ω) | Standard M&C | Standard Gain | AC + EXT Ref |
| MEDIBX100A-XF-SW | F-type (75 Ω) | Standard M&C | WGS Compatibility Option | AC + EXT Ref |
| MEDIBX100A-XN-C | Type-N (50 Ω) | Cyber Hardened | Standard Gain | AC + EXT Ref |
| MEDIBX100A-XN-CW | Type-N (50 Ω) | Cyber Hardened | WGS Compatibility Option | AC + EXT Ref |
| MEDIBX100A-XN-S | Type-N (50 Ω) | Standard M&C | Standard Gain | AC + EXT Ref |
| MEDIBX100A-XN-SW | Type-N (50 Ω) | Standard M&C | WGS Compatibility Option | AC + EXT Ref |
| MEDIBX100A-XT-C | TNC (50 Ω) | Cyber Hardened | Standard Gain | AC + EXT Ref |
| MEDIBX100A-XT-CW | TNC (50 Ω) | Cyber Hardened | WGS Compatibility Option | AC + EXT Ref |
| MEDIBX100A-XT-S | TNC (50 Ω) | Standard M&C | Standard Gain | AC + EXT Ref |
| MEDIBX100A-XT-SW | TNC (50 Ω) | Standard M&C | WGS Compatibility Option | AC + EXT Ref |
| MEDIBX100DH-XF-C | F-type (75 Ω) | Cyber Hardened | Standard Gain | DC + INT Ref Standard Stability |
| MEDIBX100DH-XF-CW | F-type (75 Ω) | Cyber Hardened | WGS Compatibility Option | DC + INT Ref Standard Stability |
| MEDIBX100DH-XF-S | F-type (75 Ω) | Standard M&C | Standard Gain | DC + INT Ref Standard Stability |
| MEDIBX100DH-XF-SW | F-type (75 Ω) | Standard M&C | WGS Compatibility Option | DC + INT Ref Standard Stability |
| MEDIBX100DH-XN-C | Type-N (50 Ω) | Cyber Hardened | Standard Gain | DC + INT Ref Standard Stability |
| MEDIBX100DH-XN-CW | Type-N (50 Ω) | Cyber Hardened | WGS Compatibility Option | DC + INT Ref Standard Stability |
| MEDIBX100DH-XN-S | Type-N (50 Ω) | Standard M&C | Standard Gain | DC + INT Ref Standard Stability |
| MEDIBX100DH-XN-SW | Type-N (50 Ω) | Standard M&C | WGS Compatibility Option | DC + INT Ref Standard Stability |
| MEDIBX100DH-XT-C | TNC (50 Ω) | Cyber Hardened | Standard Gain | DC + INT Ref Standard Stability |
| MEDIBX100DH-XT-CW | TNC (50 Ω) | Cyber Hardened | WGS Compatibility Option | DC + INT Ref Standard Stability |
| MEDIBX100DH-XT-S | TNC (50 Ω) | Standard M&C | Standard Gain | DC + INT Ref Standard Stability |
| MEDIBX100DH-XT-SW | TNC (50 Ω) | Standard M&C | WGS Compatibility Option | DC + INT Ref Standard Stability |
| MEDIBX100DS-XF-C | F-type (75 Ω) | Cyber Hardened | Standard Gain | DC + INT Ref High Stability |
| MEDIBX100DS-XF-CW | F-type (75 Ω) | Cyber Hardened | WGS Compatibility Option | DC + INT Ref High Stability |
| MEDIBX100DS-XF-S | F-type (75 Ω) | Standard M&C | Standard Gain | DC + INT Ref High Stability |
| MEDIBX100DS-XF-SW | F-type (75 Ω) | Standard M&C | WGS Compatibility Option | DC + INT Ref High Stability |
| MEDIBX100DS-XN-C | Type-N (50 Ω) | Cyber Hardened | Standard Gain | DC + INT Ref High Stability |
| MEDIBX100DS-XN-CW | Type-N (50 Ω) | Cyber Hardened | WGS Compatibility Option | DC + INT Ref High Stability |
| MEDIBX100DS-XN-S | Type-N (50 Ω) | Standard M&C | Standard Gain | DC + INT Ref High Stability |
| MEDIBX100DS-XN-SW | Type-N (50 Ω) | Standard M&C | WGS Compatibility Option | DC + INT Ref High Stability |
| MEDIBX100DS-XT-C | TNC (50 Ω) | Cyber Hardened | Standard Gain | DC + INT Ref High Stability |
| MEDIBX100DS-XT-CW | TNC (50 Ω) | Cyber Hardened | WGS Compatibility Option | DC + INT Ref High Stability |
| MEDIBX100DS-XT-S | TNC (50 Ω) | Standard M&C | Standard Gain | DC + INT Ref High Stability |
| MEDIBX100DS-XT-SW | TNC (50 Ω) | Standard M&C | WGS Compatibility Option | DC + INT Ref High Stability |
| MEDIBX100D-XF-C | F-type (75 Ω) | Cyber Hardened | Standard Gain | DC + EXT Ref |
| MEDIBX100D-XF-CW | F-type (75 Ω) | Cyber Hardened | WGS Compatibility Option | DC + EXT Ref |
| MEDIBX100D-XF-S | F-type (75 Ω) | Standard M&C | Standard Gain | DC + EXT Ref |
| MEDIBX100D-XF-SW | F-type (75 Ω) | Standard M&C | WGS Compatibility Option | DC + EXT Ref |
| MEDIBX100D-XN-C | Type-N (50 Ω) | Cyber Hardened | Standard Gain | DC + EXT Ref |
| MEDIBX100D-XN-CW | Type-N (50 Ω) | Cyber Hardened | WGS Compatibility Option | DC + EXT Ref |
| MEDIBX100D-XN-S | Type-N (50 Ω) | Standard M&C | Standard Gain | DC + EXT Ref |
| MEDIBX100D-XN-SW | Type-N (50 Ω) | Standard M&C | WGS Compatibility Option | DC + EXT Ref |
| MEDIBX100D-XT-C | TNC (50 Ω) | Cyber Hardened | Standard Gain | DC + EXT Ref |
| MEDIBX100D-XT-CW | TNC (50 Ω) | Cyber Hardened | WGS Compatibility Option | DC + EXT Ref |
| MEDIBX100D-XT-S | TNC (50 Ω) | Standard M&C | Standard Gain | DC + EXT Ref |
| MEDIBX100D-XT-SW | TNC (50 Ω) | Standard M&C | WGS Compatibility Option | DC + EXT Ref |
Specifications
| Compatible redundant switch | RSBUCMXTD11 |
|---|---|
| External reference | 10 MHz -12 to +5 dBm |
| Frequency sense | Non-Inverting |
| Output power rated | 100W |
| Reference type | External Reference / Internal High Stability / Internal Standard Stability (varies by model) |
| AM-PM conversion | < 3.0 deg/dB @ Rated Power |
| Attenuator range | 30 dB Variable in 0.1 dB Steps |
| Gain flatness (1MHz) | 0.25 dB p-p max |
| Gain flatness (36MHz) | 1.5 dB p-p max |
| Gain flatness (over full band) | 4 dB p-p max |
| Gain variation over temperature (open loop) | 3 dB p-p max |
| Gain version | Std Options and Std Specs / WGS Compatibility Option (varies by model) |
| Group delay linear | 0.03 ns/MHz |
| Group delay parabolic | 0.003 ns/MHz178 |
| Group delay ripple | 1 ns p-p Over Any 36 MHz |
| Harmonics | -60 dBc max |
| IMD3 | -27 dBc max |
| Input impedance | 50 Ohm / 75 Ohm (varies by model) |
| Input power detector range | -55 to -20 dBm / -35 to 0 dBm (varies by model) |
| Input VSWR | 1.5 : 1 |
| Level Stability with ALC | ± 0.5 dB |
| Mute | -70 dBc Max. |
| Output noise power density Rx | < -165 dBm/Hz (with RX Reject Filter) |
| Output noise power density Tx | < -75 dBm/Hz |
| Output P1dB (min.) | +50 dBm min |
| Output Plin | 46.8 dBm |
| Output spurious in band | 65 dBc |
| Output spurious out of band | Complies with MIL-STD 188–164C |
| Output VSWR | 1.5 : 1 max |
| Phase noise 0.01kHz offset (max.) | -115 dBC/Hz / -55 dBc/Hz (varies by model) |
| Phase noise 0.1kHz offset (max.) | -140 dBc/Hz / -80 dBc/Hz (varies by model) |
| Small signal gain | 81 dB min / 70 dB min (varies by model) |
| Current consumption | 850 VA / 770 W (varies by model) |
| Output power detector range | Rated Power to -20 dB |
| Power reading accuracy | ± 1.0 dB max |
| Power requirements | 100–240V AC / 42–60 VDC (varies by model) |
| Power supply | AC Powered / DC Powered, No Power Thru Coax, 48 ± 11 VDC (varies by model) |
| Output connector | CPR-112G |
| M and c interface | Cyber Hardened / Standard M&C (varies by model) |
| Option | Cyber Hardened / Standard M&C (varies by model) |
| Altitude | 10,000 ft (3,000 m) ASL |
| Humidity | 100% Condensing |
| IP rating | IP 65+ |
| Temperature, operational | -40 to +55 °C |
| Product weight | 14.9 kg / 14.5 kg (varies by model) |
| Gain variation over temperature (with AGC) | 1 dB p-p max |
| Phase noise @ 100 kHz (max.) | -100 dBc/Hz |
| Phase noise @ 1000 kHz (max.) | -110 dBc/Hz |
| Dimensions (L × W × H) | 412 × 254 × 188 mm |
Compliance and export
| Country of origin | United States of America |
|---|---|
| ECCN | EAR99 |
| HS code | 8517620090 |
| Warranty | 3 years |
Frequently asked questions
Which band version do I need?
Choose the version that covers your satellite's uplink frequencies: 7.900–8.400 GHz. Not sure? Send us your satellite and transponder details and we'll confirm.
How is it powered?
Through a separate supply: 100-240V AC and 42-60V DC. We can supply a matching power supply and cabling.
Need help sizing or integrating a transmit chain?
Digisat engineers run link budgets, select the right BUC or SSPA, and install and commission complete transmit chains for government, teleport and broadcast customers worldwide. Talk to an engineer.