Skip to product information
CPI BRK-1100, BRK-1200 redundant LNB system

CPI BRK-1100 1:1 Ku-Band Redundant LNB System, 10.95–12.75 GHz

Price on request

Quote-based pricing for government, teleport and enterprise buyers.

Need it installed, integrated or supported? Ask about Digisat engineering services.

Product details

The CPI BRK-1100 is a 1:1 redundant LNB system from CPI's BRK-1000 Series for Ku-Band earth stations. It protects one receive chain: an online LNB and a hot spare share an outdoor switch plate at the antenna hub, and the indoor controller switches to the spare automatically if the online LNB fails.

The plate takes Norsat Ku-band PLL or externally referenced LNBs, ordered separately, on a WR-75 waveguide input, in one of three LO plans: 10.95–11.70 GHz (10.00 GHz LO), 11.70–12.20 GHz (10.75 GHz LO) or 12.25–12.75 GHz (11.30 GHz LO). Options include input isolators, Tx reject filters, crossguide couplers, offline LNB ports, a remote control panel and ±48 VDC power.

Order the plate and controller as BRK-1100, choose a band plan, and specify the Norsat Ku-band LNBs separately; Digisat can quote both together. The BRK-1000 Series comes in 2 listed models; compare them on the series page.

Other models in this series

Compare all 2 CPI BRK-1000 Series Ku-Band Redundant LNB System models

Specifications

Part number BRK-1100
Series CPI BRK-1000
Input frequency 11.70–12.20 GHz (A), 12.25–12.75 GHz (B) or 10.95–11.70 GHz (C)
Output frequency 950–1450 MHz (A, B); 950–1700 MHz (C)
LO frequency 10.75 GHz (A), 11.30 GHz (B), 10.00 GHz (C) typ.
LNBs Norsat Ku-band PLL or externally referenced LNBs, ordered separately
External reference (externally referenced LNBs) 10 MHz, -5 to +5 dBm
Added system noise temperature (typ.) 10 K standard; add 2 K with couplers, 13 K with Tx reject filters, 10 K with waveguide isolators
Gain 55 dB min., 60 dB typ.
Gain flatness ±0.5 dB per 27 MHz
Gain stability ±0.25 dB max. per day at constant temperature; -0.06 dB per °C
Input VSWR 2.00:1 typ. without isolators; 1.25:1 typ., 1.30:1 max. with isolators; 1.30:1 typ., 1.35:1 max. with isolators and Tx filters
Output VSWR 1.80:1 typ., 2.00:1 max.
Output P1dB +2 dBm min. (+5 dBm typ.)
Output IP3 +12 dBm min. (+15 dBm typ.)
Frequency stability ±10 kHz, -40 °C to +60 °C
Phase noise (typ.) -65 / -75 / -80 / -90 dBc/Hz (100 Hz / 1 kHz / 10 kHz / 100 kHz)
Max. input power (no damage) 0 dBm
Desensitization threshold, 13.75–14.50 GHz -20 dBm max. without Tx filters; +30 dBm max. with Tx filters
RF input WR-75 waveguide flange
RF output and offline out Type F female (75 Ω) or Type N female (50 Ω)
Offline in, coupler in Type N female (50 Ω)
Plate operating temperature -40 °C to +60 °C
Controller 1RU, 19 in rack mount; dual redundant power supplies; universal AC input
Controller M&C 10/100Base-T Ethernet (SNMP v1/v2c/v3), RS-232/422/485 serial, parallel I/O

CPI notes that commercial Ku-band LNBs may measure up to 15 K above their stated noise temperature, so system noise depends on the LNBs fitted.