CPI's BRK-1000 Series protects a Ku-band earth station against LNB failure. Each system is an outdoor plate assembly that mounts at the antenna hub, with waveguide/coax transfer switches for Norsat Ku-band PLL or externally referenced LNBs, plus a 1RU indoor redundancy controller and the control cable between them. A 1:1 system protects one receive chain; a 1:2 system protects two chains, typically both polarizations, with one shared spare. The LNBs are ordered separately by model number, and Digisat stocks the matching Norsat Ku-band LNBs.
Key features
- Plate for Norsat Ku-band PLL or externally referenced LNBs (ordered separately)
- Three LO plans: 10.95–11.70, 11.70–12.20 or 12.25–12.75 GHz
- Outdoor plate assembly with dual waveguide/coax transfer switches, manual override and waveguide input flanges
- 1RU, 19 in rack-mount redundancy controller with dual redundant power supplies and universal AC input
- Automatic or manual switchover; the controller monitors unit current, external alarms or both
- 10/100Base-T Ethernet with SNMP v1, v2c and v3, plus RS-232/422/485 serial and parallel I/O M&C
- Front panel shows switch positions and unit status; audible alarm; CE certified and RoHS compliant
- Options: waveguide input isolators, Tx reject filters, 40 dB input crossguide couplers, offline LNB I/O ports, ±48 VDC power
- Control cable up to 500 ft (150 m) in 50 ft steps; remote control panel up to 4000 ft (1200 m) away
CPI BRK-1000 Series Ku-Band Redundant LNB System products
All 2 models
| Part number | Configuration |
|---|---|
| BRK-1100 | 1:1 |
| BRK-1200 | 1:2 |
Specifications
| Input frequency | 11.70–12.20 GHz (A), 12.25–12.75 GHz (B) or 10.95–11.70 GHz (C) |
|---|---|
| Output frequency | 950–1450 MHz (A, B); 950–1700 MHz (C) |
| LO frequency | 10.75 GHz (A), 11.30 GHz (B), 10.00 GHz (C) typ. |
| LNBs | Norsat Ku-band PLL or externally referenced LNBs, ordered separately |
| External reference (externally referenced LNBs) | 10 MHz, -5 to +5 dBm |
| Gain | 55 dB min., 60 dB typ. |
| Gain flatness | ±0.5 dB per 27 MHz |
| Gain stability | ±0.25 dB max. per day at constant temperature; -0.06 dB per °C |
| Input VSWR | 2.00:1 typ. without isolators; 1.25:1 typ., 1.30:1 max. with isolators; 1.30:1 typ., 1.35:1 max. with isolators and Tx filters |
| Output VSWR | 1.80:1 typ., 2.00:1 max. |
| Output P1dB | +2 dBm min. (+5 dBm typ.) |
| Output IP3 | +12 dBm min. (+15 dBm typ.) |
| Frequency stability | ±10 kHz, -40 °C to +60 °C |
| Phase noise (typ.) | -65 / -75 / -80 / -90 dBc/Hz (100 Hz / 1 kHz / 10 kHz / 100 kHz) |
| Max. input power (no damage) | 0 dBm |
| Desensitization threshold, 13.75–14.50 GHz | -20 dBm max. without Tx filters; +30 dBm max. with Tx filters |
| RF input | WR-75 waveguide flange |
| RF output and offline out | Type F female (75 Ω) or Type N female (50 Ω) |
| Offline in, coupler in | Type N female (50 Ω) |
| Plate operating temperature | -40 °C to +60 °C |
| Controller | 1RU, 19 in rack mount; dual redundant power supplies; universal AC input |
| Controller M&C | 10/100Base-T Ethernet (SNMP v1/v2c/v3), RS-232/422/485 serial, parallel I/O |
CPI notes that commercial Ku-band LNBs may measure up to 15 K above their stated noise temperature, so system noise depends on the LNBs fitted.
Applications
- Ku-band teleports, hubs and broadcast receive sites that can't tolerate outages
- Dual-polarization receive chains protected by one spare (1:2)
- Earth stations monitored over SNMP
Frequently asked questions
What is the difference between a 1:1 and a 1:2 system?
A 1:1 system protects one receive chain with one spare. A 1:2 system protects two chains, usually the two polarizations of a dual-pol feed, with a single shared spare, so it needs one less amplifier than two separate 1:1 systems.
Can Digisat install and commission the system?
Yes. Digisat engineers mount redundant LNA and LNB plates at the antenna hub, run and terminate the control cable, set up the controller and its SNMP monitoring, and test switchover before handover. Ask for installation when you request a quote.
Which band plan should I choose?
Band C (10.95–11.70 GHz, 10.00 GHz LO) gives a 950–1700 MHz IF; Band A (11.70–12.20 GHz, 10.75 GHz LO) and Band B (12.25–12.75 GHz, 11.30 GHz LO) give 950–1450 MHz. Match it to the transponders you receive. For full-band coverage with simultaneous low and high band outputs, see the BRK1100.1134 and BRK1200.1136 dual-output systems.
Need it installed, aligned or supported?
Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.