Skip to product information
Norsat MEDIAN X-Band GaAs BUC

Norsat MEDIAN 60W X-Band GaAs BUC

  • 7.900–8.400 GHz

Price on request · quote-based pricing for government, teleport and enterprise buyers.

  • CAGE 6U0V1
  • GPC & purchase orders accepted
  • Engineering support from Melbourne, FL

Need it installed, integrated or supported? Ask about Digisat engineering services.

Product details

The Norsat MEDIAN 60W X-Band GaAs BUC is a high-performance GaAs block upconverter from Norsat's MEDIAN line, delivering 60W of rated output power (+47.8 dBm minimum P1dB) across 7.900–8.400 GHz. It's built for teleports, gateways, broadcast uplinks and military terminals, with configurations for AC or DC power and internal or external frequency reference. All 72 orderable part numbers are listed below; tell us your requirements and we'll confirm the exact configuration.

Key features

  • 60W rated output; +47.8 dBm minimum P1dB
  • Transmit band: 7.900–8.400 GHz
  • L-band IF input: 950–1450 MHz
  • Power: 100-240V AC and 48 ± 11 VDC
  • Monitor and control: Standard M&C and Cyber Hardened
  • CPR-112G RF output; IP65+; rated −40 to +55 °C
  • Weight: 5.6 kg and 5.2 kg; 3-year warranty

Configuration options

Input connector TNC (50 Ω) · Type-N (50 Ω) · F-type (75 Ω)
M&C Option Standard M&C · Cyber Hardened
Gain Version Standard Gain · WGS Compatibility Option
Configuration AC + EXT Ref · AC + INT Ref High Stability · AC + INT Ref Standard Stability · DC + EXT Ref · DC + INT Ref High Stability · DC + INT Ref Standard Stability

All 72 part numbers

Part number Input connector M&C Option Gain Version Configuration
MEDIBX060AH-XF-C F-type (75 Ω) Cyber Hardened Standard Gain AC + INT Ref Standard Stability
MEDIBX060AH-XF-CW F-type (75 Ω) Cyber Hardened WGS Compatibility Option AC + INT Ref Standard Stability
MEDIBX060AH-XF-S F-type (75 Ω) Standard M&C Standard Gain AC + INT Ref Standard Stability
MEDIBX060AH-XF-SW F-type (75 Ω) Standard M&C WGS Compatibility Option AC + INT Ref Standard Stability
MEDIBX060AH-XN-C Type-N (50 Ω) Cyber Hardened Standard Gain AC + INT Ref Standard Stability
MEDIBX060AH-XN-CW Type-N (50 Ω) Cyber Hardened WGS Compatibility Option AC + INT Ref Standard Stability
MEDIBX060AH-XN-S Type-N (50 Ω) Standard M&C Standard Gain AC + INT Ref Standard Stability
MEDIBX060AH-XN-SW Type-N (50 Ω) Standard M&C WGS Compatibility Option AC + INT Ref Standard Stability
MEDIBX060AH-XT-C TNC (50 Ω) Cyber Hardened Standard Gain AC + INT Ref Standard Stability
MEDIBX060AH-XT-CW TNC (50 Ω) Cyber Hardened WGS Compatibility Option AC + INT Ref Standard Stability
MEDIBX060AH-XT-S TNC (50 Ω) Standard M&C Standard Gain AC + INT Ref Standard Stability
MEDIBX060AH-XT-SW TNC (50 Ω) Standard M&C WGS Compatibility Option AC + INT Ref Standard Stability
MEDIBX060AS-XF-C F-type (75 Ω) Cyber Hardened Standard Gain AC + INT Ref High Stability
MEDIBX060AS-XF-CW F-type (75 Ω) Cyber Hardened WGS Compatibility Option AC + INT Ref High Stability
MEDIBX060AS-XF-S F-type (75 Ω) Standard M&C Standard Gain AC + INT Ref High Stability
MEDIBX060AS-XF-SW F-type (75 Ω) Standard M&C WGS Compatibility Option AC + INT Ref High Stability
MEDIBX060AS-XN-C Type-N (50 Ω) Cyber Hardened Standard Gain AC + INT Ref High Stability
MEDIBX060AS-XN-CW Type-N (50 Ω) Cyber Hardened WGS Compatibility Option AC + INT Ref High Stability
MEDIBX060AS-XN-S Type-N (50 Ω) Standard M&C Standard Gain AC + INT Ref High Stability
MEDIBX060AS-XN-SW Type-N (50 Ω) Standard M&C WGS Compatibility Option AC + INT Ref High Stability
MEDIBX060AS-XT-C TNC (50 Ω) Cyber Hardened Standard Gain AC + INT Ref High Stability
MEDIBX060AS-XT-CW TNC (50 Ω) Cyber Hardened WGS Compatibility Option AC + INT Ref High Stability
MEDIBX060AS-XT-S TNC (50 Ω) Standard M&C Standard Gain AC + INT Ref High Stability
MEDIBX060AS-XT-SW TNC (50 Ω) Standard M&C WGS Compatibility Option AC + INT Ref High Stability
MEDIBX060A-XF-C F-type (75 Ω) Cyber Hardened Standard Gain AC + EXT Ref
MEDIBX060A-XF-CW F-type (75 Ω) Cyber Hardened WGS Compatibility Option AC + EXT Ref
MEDIBX060A-XF-S F-type (75 Ω) Standard M&C Standard Gain AC + EXT Ref
MEDIBX060A-XF-SW F-type (75 Ω) Standard M&C WGS Compatibility Option AC + EXT Ref
MEDIBX060A-XN-C Type-N (50 Ω) Cyber Hardened Standard Gain AC + EXT Ref
MEDIBX060A-XN-CW Type-N (50 Ω) Cyber Hardened WGS Compatibility Option AC + EXT Ref
MEDIBX060A-XN-S Type-N (50 Ω) Standard M&C Standard Gain AC + EXT Ref
MEDIBX060A-XN-SW Type-N (50 Ω) Standard M&C WGS Compatibility Option AC + EXT Ref
MEDIBX060A-XT-C TNC (50 Ω) Cyber Hardened Standard Gain AC + EXT Ref
MEDIBX060A-XT-CW TNC (50 Ω) Cyber Hardened WGS Compatibility Option AC + EXT Ref
MEDIBX060A-XT-S TNC (50 Ω) Standard M&C Standard Gain AC + EXT Ref
MEDIBX060A-XT-SW TNC (50 Ω) Standard M&C WGS Compatibility Option AC + EXT Ref
MEDIBX060DH-XF-C F-type (75 Ω) Cyber Hardened Standard Gain DC + INT Ref Standard Stability
MEDIBX060DH-XF-CW F-type (75 Ω) Cyber Hardened WGS Compatibility Option DC + INT Ref Standard Stability
MEDIBX060DH-XF-S F-type (75 Ω) Standard M&C Standard Gain DC + INT Ref Standard Stability
MEDIBX060DH-XF-SW F-type (75 Ω) Standard M&C WGS Compatibility Option DC + INT Ref Standard Stability
MEDIBX060DH-XN-C Type-N (50 Ω) Cyber Hardened Standard Gain DC + INT Ref Standard Stability
MEDIBX060DH-XN-CW Type-N (50 Ω) Cyber Hardened WGS Compatibility Option DC + INT Ref Standard Stability
MEDIBX060DH-XN-S Type-N (50 Ω) Standard M&C Standard Gain DC + INT Ref Standard Stability
MEDIBX060DH-XN-SW Type-N (50 Ω) Standard M&C WGS Compatibility Option DC + INT Ref Standard Stability
MEDIBX060DH-XT-C TNC (50 Ω) Cyber Hardened Standard Gain DC + INT Ref Standard Stability
MEDIBX060DH-XT-CW TNC (50 Ω) Cyber Hardened WGS Compatibility Option DC + INT Ref Standard Stability
MEDIBX060DH-XT-S TNC (50 Ω) Standard M&C Standard Gain DC + INT Ref Standard Stability
MEDIBX060DH-XT-SW TNC (50 Ω) Standard M&C WGS Compatibility Option DC + INT Ref Standard Stability
MEDIBX060DS-XF-C F-type (75 Ω) Cyber Hardened Standard Gain DC + INT Ref High Stability
MEDIBX060DS-XF-CW F-type (75 Ω) Cyber Hardened WGS Compatibility Option DC + INT Ref High Stability
MEDIBX060DS-XF-S F-type (75 Ω) Standard M&C Standard Gain DC + INT Ref High Stability
MEDIBX060DS-XF-SW F-type (75 Ω) Standard M&C WGS Compatibility Option DC + INT Ref High Stability
MEDIBX060DS-XN-C Type-N (50 Ω) Cyber Hardened Standard Gain DC + INT Ref High Stability
MEDIBX060DS-XN-CW Type-N (50 Ω) Cyber Hardened WGS Compatibility Option DC + INT Ref High Stability
MEDIBX060DS-XN-S Type-N (50 Ω) Standard M&C Standard Gain DC + INT Ref High Stability
MEDIBX060DS-XN-SW Type-N (50 Ω) Standard M&C WGS Compatibility Option DC + INT Ref High Stability
MEDIBX060DS-XT-C TNC (50 Ω) Cyber Hardened Standard Gain DC + INT Ref High Stability
MEDIBX060DS-XT-CW TNC (50 Ω) Cyber Hardened WGS Compatibility Option DC + INT Ref High Stability
MEDIBX060DS-XT-S TNC (50 Ω) Standard M&C Standard Gain DC + INT Ref High Stability
MEDIBX060DS-XT-SW TNC (50 Ω) Standard M&C WGS Compatibility Option DC + INT Ref High Stability
MEDIBX060D-XF-C F-type (75 Ω) Cyber Hardened Standard Gain DC + EXT Ref
MEDIBX060D-XF-CW F-type (75 Ω) Cyber Hardened WGS Compatibility Option DC + EXT Ref
MEDIBX060D-XF-S F-type (75 Ω) Standard M&C Standard Gain DC + EXT Ref
MEDIBX060D-XF-SW F-type (75 Ω) Standard M&C WGS Compatibility Option DC + EXT Ref
MEDIBX060D-XN-C Type-N (50 Ω) Cyber Hardened Standard Gain DC + EXT Ref
MEDIBX060D-XN-CW Type-N (50 Ω) Cyber Hardened WGS Compatibility Option DC + EXT Ref
MEDIBX060D-XN-S Type-N (50 Ω) Standard M&C Standard Gain DC + EXT Ref
MEDIBX060D-XN-SW Type-N (50 Ω) Standard M&C WGS Compatibility Option DC + EXT Ref
MEDIBX060D-XT-C TNC (50 Ω) Cyber Hardened Standard Gain DC + EXT Ref
MEDIBX060D-XT-CW TNC (50 Ω) Cyber Hardened WGS Compatibility Option DC + EXT Ref
MEDIBX060D-XT-S TNC (50 Ω) Standard M&C Standard Gain DC + EXT Ref
MEDIBX060D-XT-SW TNC (50 Ω) Standard M&C WGS Compatibility Option DC + EXT Ref

Specifications

Compatible redundant switch RSBUCMXTB11
External reference 10 MHz -12 to +5 dBm
Frequency sense Non-Inverting
Output power rated 60W
Reference type External Reference / Internal High Stability / Internal Standard Stability (varies by model)
AM-PM conversion < 3.0 deg/dB @ Rated Power
Attenuator range 30 dB variable in 0.1 dB steps
Gain flatness (1MHz) 0.25 dB p-p max
Gain flatness (36MHz) 1 dB p-p max
Gain flatness (over full band) 3 dB p-p max
Gain variation over temperature (open loop) 3 dB p-p max
Gain version Std Options and Std Specs / WGS Compatibility Option (varies by model)
Group delay linear 0.03 ns/MHz
Group delay parabolic 0.003 ns/MHz²
Group delay ripple 1 ns p-p Over Any 36 MHz
Harmonics -60 dBc max
IMD3 -27 dBc max
Input impedance 50 Ohm / 75 Ohm (varies by model)
Input power detector range -55 to -20 dBm / -35 to 0 dBm (varies by model)
Input VSWR 1.5 : 1
Level Stability with ALC ± 0.5 dB
Mute -70 dBc Max.
Output noise power density Rx < -79 dBm/Hz (w/o RX Reject Filer)
Output noise power density Tx < -79 dBm/Hz
Output P1dB (min.) +47.8 dBm min
Output Plin 46.8 dBm
Output spurious in band -65 dBc
Output spurious out of band Complies with MIL STD 188–164C
Output VSWR 1.5 : 1 max
Phase noise 0.01kHz offset (max.) -115 dBc/Hz / -55 dBc/Hz (varies by model)
Phase noise 0.1kHz offset (max.) -140 dBc/Hz / -80 dBc/Hz (varies by model)
Small signal gain 79 dB min / 68 dB min (varies by model)
Current consumption 430VA / 400W (varies by model)
Output power detector range Rated Power to -20 dB
Power reading accuracy ± 1.0 max
Power requirements 100–240V AC / 48 ± 11 VDC (varies by model)
Power supply AC Powered / DC Powered, No Power Thru Coax, 48 ± 11 VDC (varies by model)
Output connector CPR-112G
M and c interface Standard M&C / Cyber Hardened (varies by model)
Option Standard M&C / Cyber Hardened (varies by model)
Altitude 10,000 ft (3,000 m) ASL
Humidity 100% Condensing
IP rating IP 65+
Temperature, operational -40 to +55 °C
Product weight 5.6 kg / 5.2 kg (varies by model)
Gain variation over temperature (with AGC) 1 dB p-p max
Phase noise @ 100 kHz (max.) -100 dBc/Hz
Phase noise @ 1000 kHz (max.) -110 dBc/Hz
Dimensions (L × W × H) 267 × 152 × 155 mm

Compliance and export

Country of origin United States of America
ECCN EAR99
HS code 8517620090
Warranty 3 years

Frequently asked questions

Which band version do I need?

Choose the version that covers your satellite's uplink frequencies: 7.900–8.400 GHz. Not sure? Send us your satellite and transponder details and we'll confirm.

How is it powered?

Through a separate supply: 100-240V AC and 48 ± 11 VDC. We can supply a matching power supply and cabling.

Need help sizing or integrating a transmit chain?

Digisat engineers run link budgets, select the right BUC or SSPA, and install and commission complete transmit chains for government, teleport and broadcast customers worldwide. Talk to an engineer.