Skip to product information
Norsat ELEMENT 100W C-Band BUC

Norsat ELMTBC100HT-IF-AM ELEMENT 100W C-Band BUC, 6.725–7.025 GHz, F-Type In, 85–265 VAC + RS-232 & RS-485, High-Temp

Price on request

Quote-based pricing for government, teleport and enterprise buyers.

Need it installed, integrated or supported? Ask about Digisat engineering services.

Product details

The Norsat ELMTBC100HT-IF-AM is an ELEMENT 100W C-Band BUC from Norsat's ELEMENT line. It upconverts an L-band IF of 975–1275 MHz to 6.725–7.025 GHz using a 5.75 GHz local oscillator, delivering 100W rated output.

This configuration: Input connector: F-type (75 Ω); Power + M&C: 85–265 VAC + RS-232 & RS-485; Reference: Standard version; Temperature range: High-temperature range. It runs on +85 to +265V AC, drawing 630W max.

Need a different configuration? The ELEMENT 100W C-Band BUC Series comes in 96 part numbers. Compare them on the series page.

Other configurations

Compare all 96 Norsat ELEMENT 100W C-Band BUC models

Specifications

Part number ELMTBC100HT-IF-AM
Series Norsat ELEMENT 100W C-Band BUC
Frequency plan IF 975–1275 MHz → LO 5.75 GHz → RF 6.725–7.025 GHz
Input connector F-type (75 Ω)
Power + M&C 85–265 VAC + RS-232 & RS-485
Reference Standard version
Temperature range High-temperature range
External reference 10 MHz, -5 to +5 dBm
Output power rated 100W
Reference type Internal Reference
Gain flatness (54MHz) 1.5 dB
Gain Flatness (over full band) 4 dB
Gain Flatness (over temperature) 4 dB
Input VSWR 2 : 1 max.
Linear gain (typ.) 80 dB
Output P1dB (min.) +50 dBm over temperature
Output spurious in band -60 dBc
Output spurious out of band -50 dBc
Output VSWR 2 : 1 max.
Phase noise 0.1kHz offset (max.) -65 dBc/Hz
Phase noise @ 1 kHz (max.) -75 dBc/Hz
Phase noise @ 10 kHz (max.) -85 dBc/Hz
Phase noise @ 100 kHz (max.) -95 dBc/Hz
Current consumption 650W max.
Power consumption 630W max.
Power requirements +85 to +265V AC
Frequency sense Non-inverted
M and c interface RS-232 & RS-485
Function CMD HPA On/Off, Gain Control, Address Change
Function TLM Output Power Detection, Out-of-lock Alarm, Temperature, Summary Alarm
Mute control Via M&C Interface or Disconnection 10MHz Reference
Status LED Bicolor: Red(Abnormal), Green(Normal)
Humidity Up to 100%
IP rating IP 54
Temperature, operational -40 to +60 °C
Temperature, storage -40 to +75 °C
Internal function Lock detector shuts off Tx in case of LO unlocked
Product weight 8.5 kg
Dimensions (L × W × H) 235 × 190 × 145 mm