The Norsat ELMTBC080HT-PN-AM is an ELEMENT 80W C-Band BUC from Norsat's ELEMENT line. It upconverts an L-band IF of 1150–1450 MHz to 6.425–6.725 GHz using a 5.275 GHz local oscillator, delivering 80W rated output (+49 dBm over temperature minimum P1dB).
This configuration: Input connector: Type-N (50 Ω); Power + M&C: 85–265 VAC + RS-232 & RS-485; Reference: Standard version; Temperature range: High-temperature range. It runs on +85 to +265V AC, drawing 630W max.
Need a different configuration? The ELEMENT 80W C-Band BUC Series comes in 128 part numbers. Compare them on the series page.
Other configurations
- Band: S: 5.850–6.425 GHz (ELMTBC080HT-SN-AM) · I: 6.725–7.025 GHz (ELMTBC080HT-IN-AM) · W: 5.850–6.725 GHz (ELMTBC080HT-WN-AM)
- Input connector: F-type (75 Ω) (ELMTBC080HT-PF-AM)
- Power + M&C: 85–265 VAC + No M&C Function (ELMTBC080HT-PN-A) · 85–265 VAC + Ethernet (ELMTBC080HT-PN-AE) · 85–265 VAC + Ethernet + RS-232 & RS-485 (ELMTBC080HT-PN-AEM)
- Reference: EXT REF version (ELMTBC080T-PN-AM)
- Temperature range: Standard range (ELMTBC080H-PN-AM)
Compare all 128 Norsat ELEMENT 80W C-Band BUC models
Specifications
| Part number | ELMTBC080HT-PN-AM |
|---|---|
| Series | Norsat ELEMENT 80W C-Band BUC |
| Frequency plan | IF 1150–1450 MHz → LO 5.275 GHz → RF 6.425–6.725 GHz |
| Input connector | Type-N (50 Ω) |
| Power + M&C | 85–265 VAC + RS-232 & RS-485 |
| Reference | Standard version |
| Temperature range | High-temperature range |
| External reference | 10 MHz, -5 to +5 dBm |
| Output power rated | 80W |
| Reference type | Internal Reference |
| Gain flatness (54MHz) | 1.5 dB |
| Gain Flatness (over full band) | 4 dB |
| Gain Flatness (over temperature) | 4 dB |
| Input VSWR | 2 : 1 max. |
| Linear gain (typ.) | 80 dB |
| Output P1dB (min.) | +49 dBm min. over temperature |
| Output spurious in band | -60 dBc |
| Output spurious out of band | -50 dBc |
| Output VSWR | 2 : 1 max. |
| Phase noise 0.1kHz offset (max.) | -65 dBc/Hz |
| Phase noise @ 1 kHz (max.) | -75 dBc/Hz |
| Phase noise @ 10 kHz (max.) | -85 dBc/Hz |
| Phase noise @ 100 kHz (max.) | -95 dBc/Hz |
| Current consumption | 650W max. |
| Power consumption | 630W max. |
| Power requirements | +85 to +265V AC |
| Frequency sense | Non-inverted |
| M and c interface | RS-232 & RS-485 |
| Function CMD | HPA On/Off, Gain Control, Address Change |
| Function TLM | Output Power Detection, Out-of-lock Alarm, Temperature, Summary Alarm |
| Mute control | Via M&C Interface or Disconnection 10MHz Reference |
| Status LED | Bicolor: Red(Abnormal), Green(Normal) |
| Humidity | Up to 100% |
| IP rating | IP 54 |
| Temperature, operational | -40 to +60 °C |
| Temperature, storage | -40 to +75 °C |
| Internal function | Lock detector shuts off Tx in case of LO unlocked |
| Product weight | 8.5 kg |
| Dimensions (L × W × H) | 235 × 190 × 145 mm |
Compliance and export
| Country of origin | Republic of Korea |
|---|---|
| ECCN | EAR99 |
| HS code | 8543700000 |
| Warranty | 3 years |