Skip to product information
CPI RSC11V1-AC, RSC12V1-AC, RSCD1V1-AC Redundancy Controller

CPI RSC11V1-AC 1:1 Redundant System Controller

Price on request

Quote-based pricing for government, teleport and enterprise buyers.

Need it installed, integrated or supported? Ask about Digisat engineering services.

Product details

The CPI RSC11V1-AC is a 1RU controller for 1:1 redundant systems: one online unit and one backup. It powers LNAs or LNBs directly and monitors their current, watches external alarms such as SSPA summary faults, and drives the RF transfer switch to bring the backup online within 100 ms of a fault.

It has Ethernet with a web page and SNMP v1/v2c/v3, serial and parallel I/O, and dual AC inputs with dual redundant power supplies. It replaces CPI's legacy RSC-1100 controllers and RCP-1100 remote panels.

The RSCxx Redundant System Controller Series comes in 3 listed models; compare them on the series page.

Other models in this series

Compare all 3 CPI RSCxx Series Redundant System Controllers models

Specifications

Part number RSC11V1-AC
Series CPI RSCxx Redundant System Controller
Configuration 1:1 (two units)
Unit monitoring Unit bias current (±5% to ±25% window, 5% steps), external alarms, or both
Switchover time 100 ms max.
Unit power outputs +14.3 to +15.0 VDC, 600 mA max. per unit
Switch drive outputs -22 to -28 VDC, 2 A max.
External alarm inputs Optional, up to one per unit; sink 5 mA at 5 VDC to negate
Network 10/100Base-T Ethernet; internal web page; SNMP v1, v2c and v3
Serial I/O RS-232 / RS-422 / RS-485 (2- or 4-wire), user selectable
Parallel I/O Contact-closure control inputs; Form C dry-contact status outputs (100 VDC, 0.5 A, 3W max.)
Remote control panel A second RSC can mirror the primary from up to 4000 ft (1200 m)
Control cable 100–250 ft (30–75 m) in 50 ft steps standard; up to 500 ft (150 m) special order; ordered separately
AC input 100–135 or 180–240 VAC, 47–63 Hz, 100W; dual AC inputs, dual redundant power supplies
Size / weight 19 W × 1.72 H × 17.5 D in (483 × 43.7 × 445 mm), 1RU; 7.6 lb (3.4 kg); slides standard
Operating temperature 0 °C to +50 °C indoor; storage -40 °C to +70 °C
Reliability MTBF 48,200 hours; MTTR under 30 minutes with spares
Compliance CE certified, RoHS compliant; EAR99

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.