Skip to product information
CPI LRX-1000 X-Band Redundant LNA System

CPI LRX2 1:2 X-Band Redundant LNA System, 7.25–7.75 GHz

Price on request

Quote-based pricing for government, teleport and enterprise buyers.

Need it installed, integrated or supported? Ask about Digisat engineering services.

Product details

The CPI LRX2 is a 1:2 redundant LNA system from CPI's LRX-1000 Series for X-Band earth stations. It protects two receive chains, typically both polarizations of a dual-pol feed, with one shared spare LNA. If either online LNA fails, the indoor controller switches the spare into that chain automatically.

The plate carries CPI LX-7000 Series LNAs (45 or 50 K) on a CPR-112G waveguide input, with options for a -55 dB, 7.9–8.4 GHz Tx reject filter, LNA interstage filters, -40 dB input crossguide couplers, -20 dB output couplers and an offline I/O port. The 1RU controller has dual power supplies and SNMP over Ethernet.

Order it as LRX2XXX-XXXXXXX; Digisat completes the order code from your band, LNA and option choices. The LRX-1000 Series comes in 2 listed models; compare them on the series page.

Other models in this series

Compare all 2 CPI LRX-1000 Series X-Band Redundant LNA System models

Specifications

Part number LRX2XXX-XXXXXXX
Series CPI LRX-1000
Frequency range 7.25–7.75 GHz
LNAs CPI LX-7000 Series, 45 or 50 K
Added system noise temperature (typ.) Pol. 1 / pol. 2 / standby: 3 / 7 / 12 K standard; 28 / 32 / 37 K with Tx reject filter
Gain 58 dB min., 60 dB typ.; 48 dB min., 50 dB typ. with LNA Option 1
Gain match between LNAs 1 dB
Gain flatness ±0.75 dB full band; ±0.30 dB per 40 MHz
Gain stability ±0.2 dB max. per day at constant temperature; -0.04 dB per °C typ.
Input VSWR 1.20:1 typ., 1.25:1 max.; 1.25:1 typ., 1.30:1 max. with Tx filter
Output VSWR 1.20:1 typ., 1.25:1 max.
Output P1dB +10 dBm min. (+13 dBm typ.); +18 dBm min. with LNA Option 2; +17 dBm min. with LNA Option 2 and output couplers
Output IP3 +20 dBm min. (+23 dBm typ.); +28 dBm min. with LNA Option 2; +27 dBm min. with LNA Option 2 and output couplers
Group delay per 40 MHz 0.02 ns/MHz linear, 0.002 ns/MHz² parabolic, 0.2 ns p-p ripple
AM/PM conversion 0.05°/dB max. at -5 dBm output
Max. input power (no damage) 0 dBm
Desensitization threshold, 7.9–8.4 GHz -30 dBm with LNA interstage filter; +5 dBm with Tx reject filter; +25 dBm with both
RF input CPR-112G waveguide flange
RF output, offline and coupler ports Type N female
Plate supply 11 V min., 15 V typ., 24 V max. DC; 10 W typ.
Plate operating temperature -40 °C to +60 °C
Controller 1RU, 19 in rack mount; dual redundant power supplies; universal AC input
Controller M&C 10/100Base-T Ethernet (SNMP v1/v2c/v3), RS-232/422/485 serial, parallel I/O

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.