CPI LRX2 1:2 X-Band Redundant LNA System, 7.25–7.75 GHz
Quote-based pricing for government, teleport and enterprise buyers.
Need it installed, integrated or supported? Ask about Digisat engineering services.
Product details
The CPI LRX2 is a 1:2 redundant LNA system from CPI's LRX-1000 Series for X-Band earth stations. It protects two receive chains, typically both polarizations of a dual-pol feed, with one shared spare LNA. If either online LNA fails, the indoor controller switches the spare into that chain automatically.
The plate carries CPI LX-7000 Series LNAs (45 or 50 K) on a CPR-112G waveguide input, with options for a -55 dB, 7.9–8.4 GHz Tx reject filter, LNA interstage filters, -40 dB input crossguide couplers, -20 dB output couplers and an offline I/O port. The 1RU controller has dual power supplies and SNMP over Ethernet.
Order it as LRX2XXX-XXXXXXX; Digisat completes the order code from your band, LNA and option choices. The LRX-1000 Series comes in 2 listed models; compare them on the series page.
Other models in this series
- LRX1: 1:1 system
Compare all 2 CPI LRX-1000 Series X-Band Redundant LNA System models
Specifications
| Part number | LRX2XXX-XXXXXXX |
|---|---|
| Series | CPI LRX-1000 |
| Frequency range | 7.25–7.75 GHz |
| LNAs | CPI LX-7000 Series, 45 or 50 K |
| Added system noise temperature (typ.) | Pol. 1 / pol. 2 / standby: 3 / 7 / 12 K standard; 28 / 32 / 37 K with Tx reject filter |
| Gain | 58 dB min., 60 dB typ.; 48 dB min., 50 dB typ. with LNA Option 1 |
| Gain match between LNAs | 1 dB |
| Gain flatness | ±0.75 dB full band; ±0.30 dB per 40 MHz |
| Gain stability | ±0.2 dB max. per day at constant temperature; -0.04 dB per °C typ. |
| Input VSWR | 1.20:1 typ., 1.25:1 max.; 1.25:1 typ., 1.30:1 max. with Tx filter |
| Output VSWR | 1.20:1 typ., 1.25:1 max. |
| Output P1dB | +10 dBm min. (+13 dBm typ.); +18 dBm min. with LNA Option 2; +17 dBm min. with LNA Option 2 and output couplers |
| Output IP3 | +20 dBm min. (+23 dBm typ.); +28 dBm min. with LNA Option 2; +27 dBm min. with LNA Option 2 and output couplers |
| Group delay per 40 MHz | 0.02 ns/MHz linear, 0.002 ns/MHz² parabolic, 0.2 ns p-p ripple |
| AM/PM conversion | 0.05°/dB max. at -5 dBm output |
| Max. input power (no damage) | 0 dBm |
| Desensitization threshold, 7.9–8.4 GHz | -30 dBm with LNA interstage filter; +5 dBm with Tx reject filter; +25 dBm with both |
| RF input | CPR-112G waveguide flange |
| RF output, offline and coupler ports | Type N female |
| Plate supply | 11 V min., 15 V typ., 24 V max. DC; 10 W typ. |
| Plate operating temperature | -40 °C to +60 °C |
| Controller | 1RU, 19 in rack mount; dual redundant power supplies; universal AC input |
| Controller M&C | 10/100Base-T Ethernet (SNMP v1/v2c/v3), RS-232/422/485 serial, parallel I/O |
Need it installed, aligned or supported?
Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.