CPI LRL1 1:1 L-Band Redundant LNA System, 1510–1577 MHz
Quote-based pricing for government, teleport and enterprise buyers.
Need it installed, integrated or supported? Ask about Digisat engineering services.
Product details
The CPI LRL1 is a 1:1 redundant LNA system from CPI's LRL-1000 Series for L-Band earth stations. It protects one receive chain: an online LNA and a hot spare share an outdoor switch plate at the antenna hub, and the indoor controller switches to the spare automatically if the online LNA fails.
The plate carries CPI LL-1500 Series LNAs (35, 40 or 45 K), with options for -30 dB input couplers, -20 dB output couplers and an offline I/O port. The 1RU controller has dual power supplies and SNMP over Ethernet.
Order it as LRL1XXX-XXXXXXX; Digisat completes the order code from your band, LNA and option choices. The LRL-1000 Series comes in 2 listed models; compare them on the series page.
Other models in this series
- LRL2: 1:2 system
Compare all 2 CPI LRL-1000 Series L-Band Redundant LNA System models
Specifications
| Part number | LRL1XXX-XXXXXXX |
|---|---|
| Series | CPI LRL-1000 |
| Frequency range | 1510–1577 MHz |
| LNAs | CPI LL-1500 Series, 35, 40 or 45 K |
| Added system noise temperature (typ.) | 10 K standard; 40 K with input couplers |
| Gain | 48 dB min., 51 dB typ.; 58 dB min., 61 dB typ. with LNA Option 1 |
| Gain match between LNAs | 2 dB max. |
| Gain flatness | ±0.75 dB full band; ±0.30 dB per 10 MHz |
| Gain stability | ±0.2 dB max. per day at constant temperature; -0.04 dB per °C |
| Input VSWR | 1.25:1 typ., 1.30:1 max.; 1.30:1 typ., 1.40:1 max. with input couplers |
| Output VSWR | 1.20:1 typ., 1.25:1 max. |
| Output P1dB | +8 dBm min. (+11 dBm typ.); +18 dBm min. with LNA Option 2; +17 dBm min. with LNA Option 2 and output couplers |
| Output IP3 | +18 dBm min. (+21 dBm typ.); +28 dBm min. with LNA Option 2; +27 dBm min. with LNA Option 2 and output couplers |
| Group delay per 36 MHz | 0.05 ns/MHz linear, 0.005 ns/MHz² parabolic, 1.0 ns p-p ripple |
| AM/PM conversion | 0.05°/dB max. at -5 dBm output |
| Max. input power (no damage) | +10 dBm |
| Desensitization threshold, 1.625–1.661 GHz | -50 dBm max.; -60 dBm with 60 dB gain LNAs |
| RF input | SMA female; Type N female with input couplers |
| RF output, offline and coupler ports | Type N female |
| Plate supply | 11 V min., 15 V typ., 24 V max. DC; 6 W typ. |
| Plate operating temperature | -40 °C to +60 °C |
| Controller | 1RU, 19 in rack mount; dual redundant power supplies; universal AC input |
| Controller M&C | 10/100Base-T Ethernet (SNMP v1/v2c/v3), RS-232/422/485 serial, parallel I/O |