Skip to product information
CPI LRKA Ka-band redundant LNA system

CPI LRKA2 1:2 Ka-Band Redundant LNA System, 17.7–21.2 GHz

Price on request

Quote-based pricing for government, teleport and enterprise buyers.

Need it installed, integrated or supported? Ask about Digisat engineering services.

Product details

The CPI LRKA2 is a 1:2 redundant LNA system from CPI's LRKA-1000 Series for Ka-Band earth stations. It protects two receive chains, typically both polarizations of a dual-pol feed, with one shared spare LNA. If either online LNA fails, the indoor controller switches the spare into that chain automatically.

The plate carries CPI LK-20S000 Series LNAs (110 or 120 K) on a WR-42 waveguide input, with options for an 85 dB, 27.5–31.0 GHz Tx reject filter, -40 dB input crossguide couplers, -20 dB output couplers, an offline I/O port and green or tan LNA finishes. The 1RU controller has dual power supplies and SNMP over Ethernet.

Order it as LRKA2XXX-XXXXXXX; Digisat completes the order code from your band, LNA and option choices. The LRKA-1000 Series comes in 2 listed models; compare them on the series page.

Other models in this series

Compare all 2 CPI LRKA-1000 Series Ka-Band Redundant LNA System models

Specifications

Part number LRKA2XXX-XXXXXXX
Series CPI LRKA-1000
Frequency range 18.2–20.2 GHz (A), 20.2–21.2 GHz (B) or 17.7–21.2 GHz (C)
LNAs CPI LK-20S000 Series, 110 K (bands A and B) or 120 K
Added system noise temperature (typ.) Pol. 1 / pol. 2 / standby: 7 / 11 / 16 K standard; 18 / 22 / 27 K with Tx reject filter
Gain 56 dB min.; 46 dB min. with LNA Option 1
Gain flatness ±1.5 dB full band; ±0.5 dB per 40 MHz
Gain stability, constant temperature ±0.1 dB (10 min), ±0.2 dB (24 h), ±0.5 dB (1 week) typ.
Gain vs. temperature 5.0 dB p-p typ.
Input VSWR 1.50:1 typ.
Output VSWR 1.25:1 typ.
Output P1dB +10 dBm min.; +18 dBm min. with LNA Option 2; +17 dBm min. with LNA Option 2 and output couplers
Output IP3 +20 dBm min.; +25 dBm min. with LNA Option 2; +24 dBm min. with LNA Option 2 and output couplers
Group delay per 40 MHz 0.02 ns/MHz linear, 0.002 ns/MHz² parabolic, 0.40 ns p-p ripple
AM/PM conversion 0.05°/dB max. at -5 dBm output
Max. input power (no damage) 0 dBm
Desensitization threshold, 27.0–31.0 GHz -15 dBm standard; +35 dBm with Tx reject filter
RF input WR-42 waveguide flange
RF output, offline and coupler ports SMA female (Type N female on request)
Plate supply 11 VDC min., 28 VDC max.; 10 W typ.
Plate operating temperature -40 °C to +60 °C
Controller 1RU, 19 in rack mount; dual redundant power supplies; universal AC input
Controller M&C 10/100Base-T Ethernet (SNMP v1/v2c/v3), RS-232/422/485 serial, parallel I/O

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.