Skip to product information
CPI LRK Ku-band redundant LNA system

CPI LRK2 1:2 Ku-Band Redundant LNA System, 10.70–12.75 GHz

Price on request

Quote-based pricing for government, teleport and enterprise buyers.

Need it installed, integrated or supported? Ask about Digisat engineering services.

Product details

The CPI LRK2 is a 1:2 redundant LNA system from CPI's LRK-1000 Series for Ku-Band earth stations. It protects two receive chains, typically both polarizations of a dual-pol feed, with one shared spare LNA. If either online LNA fails, the indoor controller switches the spare into that chain automatically.

The plate carries CPI LK-12000 Series LNAs (65 to 90 K) on a WR-75 waveguide input, with options for a 13.75–14.50 GHz Tx reject filter, -40 dB input crossguide couplers, -20 dB output couplers and an offline I/O port. The 1RU controller has dual power supplies and SNMP over Ethernet.

Order it as LRK2XXX-XXXXXXX; Digisat completes the order code from your band, LNA and option choices. The LRK-1000 Series comes in 2 listed models; compare them on the series page.

Other models in this series

Compare all 2 CPI LRK-1000 Series Ku-Band Redundant LNA System models

Specifications

Part number LRK2XXX-XXXXXXX
Series CPI LRK-1000
Frequency range 10.95–12.75 GHz (Band E) or 10.70–12.75 GHz (Band R)
LNAs CPI LK-12000 Series, 65, 70, 80 or 90 K
Added system noise temperature (typ.) Pol. 1 / pol. 2 / standby: 5 / 9 / 14 K standard; 18 / 22 / 27 K with Tx reject filter
Gain 60 dB min., 63 dB typ.; 50 dB min., 53 dB typ. with LNA Option 1
Gain match between LNAs 1 dB max.
Gain flatness ±0.75 dB full band; ±0.30 dB per 40 MHz
Gain stability ±0.2 dB max. per day at constant temperature; -0.04 dB per °C
Input VSWR 1.20:1 typ., 1.25:1 max.; 1.25:1 typ., 1.30:1 max. with Tx filter
Output VSWR 1.20:1 typ., 1.25:1 max.
Output P1dB +10 dBm min. (+13 dBm typ.); +18 dBm min. with LNA Option 2; +17 dBm min. with LNA Option 2 and output couplers
Output IP3 +20 dBm min. (+23 dBm typ.); +28 dBm min. with LNA Option 2; +27 dBm min. with LNA Option 2 and output couplers
Group delay per 40 MHz 0.02 ns/MHz linear, 0.002 ns/MHz² parabolic, 0.2 ns p-p ripple
AM/PM conversion 0.05°/dB max. at -5 dBm output
Max. input power (no damage) 0 dBm
Desensitization threshold, 13.75–14.50 GHz -20 dBm standard; +30 dBm with Tx reject filter
RF input WR-75 waveguide flange
RF output, offline and coupler ports Type N female (SMA female on request)
Plate supply LNAs: 11–24 VDC (15 V typ.), 10 W typ.; switches: 28 VDC typ., 2 A max.
Plate operating temperature -40 °C to +60 °C
Controller 1RU, 19 in rack mount; dual redundant power supplies; universal AC input
Controller M&C 10/100Base-T Ethernet (SNMP v1/v2c/v3), RS-232/422/485 serial, parallel I/O

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.