Skip to product information
CPI LL-1500 L-Band LNA

CPI LLB15S35 L-Band LNA, 1510–1577 MHz, 35 K

Price on request

Quote-based pricing for government, teleport and enterprise buyers.

Need it installed, integrated or supported? Ask about Digisat engineering services.

Product details

The CPI LLB15S35 is a L-Band low noise amplifier (LNA) from CPI's LL-1500 Series. It covers 1510–1577 MHz with a maximum noise temperature of 35 K at +23 °C, guaranteed across the full band.

It uses a HEMT/MMIC design with an internal regulator, reverse polarity protection and a fault alarm, and provides 50 dB minimum gain (60 dB optional) with ±0.5 dB flatness. Connectors are SMA, and it runs on +11 to +15 VDC from -40 °C to +60 °C.

Order it as LLB15S35-XX: the suffix selects gain (50 dB standard or 60 dB) and output power (+10 or +20 dBm). The LL-1500 Series comes in 3 listed models; compare them on the series page.

Other models in this series

Compare all 3 CPI LL-1500 Series L-Band LNA models

Specifications

Part number LLB15S35-XX
Series CPI LL-1500
Frequency range 1510–1577 MHz
Noise temperature (max., +23 °C) 35, 40 or 45 K
Gain 50 dB min., 53 dB typ., 55 dB max.; 60 dB min., 63 dB typ., 65 dB max. with Option 1
Gain flatness ±0.5 dB full band; ±0.25 dB per 10 MHz
Input VSWR 1.20:1 typ., 1.25:1 max.
Output VSWR 1.25:1 typ., 1.30:1 max.
Output P1dB +10 dBm min. (+13 dBm typ.); +20 dBm min. (+21 dBm typ.) with Option 2
Output IP3 +20 dBm min. (+23 dBm typ.); +30 dBm min. (+33 dBm typ.) with Option 2
Group delay per 36 MHz 0.05 ns/MHz linear, 0.005 ns/MHz² parabolic, 1.0 ns p-p ripple
AM/PM conversion 0.05°/dB max. at -5 dBm output
Gain stability, constant temperature ±0.1 dB (10 min), ±0.2 dB (24 h), ±0.5 dB (1 week) max.
Gain vs. temperature -0.04 dB per °C
Max. input power (damage) +10 dBm
Desensitization threshold, 1625–1661 MHz -50 dBm max.; -60 dBm with Option 1
RF input SMA male
RF output SMA female
Power connector PT02E10-6P-027 (mate supplied)
Supply voltage +11 V min., +12 V typ., +15 V max. DC
Current 150 mA typ., 175 mA max.; 200 mA typ., 220 mA max. with Option 1 or 2
Alarm Fault alarm, open or closed on fault
Operating temperature -40 °C to +60 °C

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.