The CPI LKR12S65 is a Ku-Band low noise amplifier (LNA) from CPI's LK-12000 Series. It covers 10.70–12.75 GHz (full Ku-band receive) with a maximum noise temperature of 65 K at +23 °C, guaranteed across the full band.

It provides 60 dB minimum gain (64 dB typical) with ±0.5 dB flatness across the band, a WR-75 waveguide input with input and output isolators, and an SMA output (Type N optional). DC can be fed up the RF output cable or through the MS power connector.

Order it as LKR12S65-XXXX: the suffix selects gain (60 or 50 dB), output power (+12 or +20 dBm), DC or AC power, and an SMA or Type N output. The LK-12000 Series comes in 4 listed models; compare them on the series page.

Other models in this series

Compare all 4 CPI LK-12000 Series Ku-Band LNA models

Specifications

Part number LKR12S65-XXXX
Series CPI LK-12000
Frequency range 10.95–12.75 GHz (Band E) or 10.70–12.75 GHz (Band R)
Noise temperature (max., +23 °C) 65, 70, 80 or 90 K
Gain 60 dB min., 64 dB typ., 66 dB max.; 50 dB min., 53 dB typ., 56 dB max. with Option 1
Gain flatness ±0.5 dB full band; ±0.20 dB per 40 MHz
Input VSWR 1.20:1 typ., 1.25:1 max.
Output VSWR 1.20:1 typ., 1.50:1 max.
Output P1dB +12 dBm min. (+15 dBm typ.); +20 dBm min. (+22 dBm typ.) with Option 2
Output IP3 +22 dBm min. (+25 dBm typ.); +30 dBm min. (+32 dBm typ.) with Option 2
Group delay per 40 MHz 0.01 ns/MHz linear, 0.001 ns/MHz² parabolic, 0.1 ns p-p ripple
AM/PM conversion 0.05°/dB max. at -5 dBm output
Gain stability, constant temperature ±0.1 dB (10 min), ±0.2 dB (24 h), ±0.5 dB (1 week) max.
Gain vs. temperature -0.04 dB per °C
Max. input power (damage) 0 dBm
Desensitization threshold, 13.75–14.50 GHz -20 dBm max.
RF input WR-75 cover flange
RF output SMA female; Type N female with Option 7
Power connector PT02E10-6P-027 (mate supplied); DC can also be fed through the RF output cable
Supply voltage +12 V min., +15 V typ., +24 V max. DC; 90–265 VAC option
Current 140 mA typ., 210 mA max.; 270 mA typ., 330 mA max. with Option 2
Alarm Form C
Operating temperature -40 °C to +70 °C
MTBF 130,000 hours (MIL-HDBK-217F, ground fixed, +40 °C)

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.