Skip to product information
CPI LC-4000 C-Band LNA

CPI LCD4S35 C-Band LNA, 3.4–4.2 GHz, 35 K

Price on request

Quote-based pricing for government, teleport and enterprise buyers.

Need it installed, integrated or supported? Ask about Digisat engineering services.

Product details

The CPI LCD4S35 is a C-Band low noise amplifier (LNA) from CPI's LC-4000 Series. It covers 3.4–4.2 GHz (extended C-band) with a maximum noise temperature of 35 K at +23 °C, guaranteed across the full band.

It provides 60 dB minimum gain (64 dB typical) with ±0.5 dB flatness across the band, a CPR-229G waveguide input with an internal low-loss isolator, and a Type N output. Every unit is cold-load tested and has an internal Form C alarm, reverse polarity and surge protection.

Order it as LCD4S35-XX: the suffix selects output power (+10 dBm standard or +20 dBm) and DC or universal AC power. The LC-4000 Series comes in 4 listed models; compare them on the series page.

Other models in this series

Compare all 4 CPI LC-4000 Series C-Band LNA models

Specifications

Part number LCD4S35-XX
Series CPI LC-4000
Frequency range 3.6–4.2 GHz (Band C) or 3.4–4.2 GHz (Band D)
Noise temperature (max., +23 °C) 30, 35, 40 or 45 K
Gain 60 dB min., 64 dB typ., 66 dB max.
Gain flatness ±0.5 dB max. full band; ±0.2 dB max. per 40 MHz
Input VSWR 1.20:1 typ., 1.25:1 max.
Output VSWR 1.20:1 typ., 1.50:1 max.
Output P1dB +10 dBm min. (+15 dBm typ.); +20 dBm min. (+22 dBm typ.) with Option 2
Output IP3 +20 dBm min. (+26 dBm typ.); +30 dBm min. (+32 dBm typ.) with Option 2
Group delay per 40 MHz 0.01 ns/MHz linear, 0.001 ns/MHz² parabolic, 0.1 ns p-p ripple
AM/PM conversion 0.05°/dB max. at -5 dBm output
Gain stability, constant temperature ±0.1 dB (10 min), ±0.2 dB (24 h), ±0.5 dB (1 week) max.
Gain vs. temperature -0.05 dB per °C
Max. input power (damage) 0 dBm
Desensitization threshold, 5.825–6.425 GHz -10 dBm max.
RF input CPR-229G flange
RF output Type N female
Power connector PT02E10-6P-027 (mate supplied)
Supply voltage +12 V min., +15 V typ., +24 V max. DC; 90–265 VAC option
Current 140 mA typ., 180 mA max.; 200 mA typ., 240 mA max. with Option 2
Alarm Internal Form C
Operating temperature -40 °C to +70 °C
MTBF 296,000 hours (MIL-HDBK-217F, ground fixed, +40 °C)

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.