{"title":"Terrasat","description":"\u003cp\u003eTerrasat Communications builds IBUC Intelligent Block Upconverters: compact GaAs and GaN BUCs from 4 W to 800 W in C, X, Ku and Ka-band, multi-band Ka-band units for multi-orbit networks, Tx and Rx redundancy systems, load switches and the Cyber Hardened Core encrypted M\u0026amp;C option.\u003c\/p\u003e\u003cp\u003eDigisat supplies Terrasat equipment with quote-based pricing for government, teleport and enterprise buyers, accepts purchase orders and GPC, and our engineers can help size, integrate, install and support the equipment. Browse 29 Terrasat part numbers below.\u003c\/p\u003e","products":[{"product_id":"terrasat-ibuc-2-c-band-10-80w-buc","title":"Terrasat IBUC 2 C-Band 10–80W GaAs Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 2 is a compact C-band Intelligent BUC: a block upconverter and GaAs solid-state power amplifier in one outdoor unit, from 10 W to 80 W. It is built for VSAT, SCPC and network terminals in telecom, defense, air traffic control and government networks, with RJ45 Ethernet M\u0026amp;C, SNMP and a web interface for remote monitoring. The frequency plan is set at the factory: standard, extended, full or INSAT C-band.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e10 W to 80 W P1dB (+40 to +49 dBm min)\u003c\/li\u003e\n\u003cli\u003eStandard, extended, full (5.850–6.725 GHz) or INSAT C-band\u003c\/li\u003e\n\u003cli\u003eAC or DC power; 24 VDC and DC-over-coax options on lower-power models\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy and internal 10 MHz reference options\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 2 10–80W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 2 10–80W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard C-band 5.850–6.425 GHz; Extended C-band 5.850–6.650 GHz; Full C-band 5.850–6.725 GHz; INSAT C-band 6.725–7.025 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1525 MHz (standard C) to 950–1825 MHz (full C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power (P1dB)\u003c\/th\u003e\n\u003ctd\u003e10 W +40 dBm; 15 W +41.8; 20 W +43; 25 W +44; 30 W +44.8; 40 W +46; 50 W +47; 60 W +47.8; 80 W +49 dBm (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaAs SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e71–80 dB min (standard); 60–69 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω or TNC 50 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eCPR-137G waveguide or Type N female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral sense\u003c\/th\u003e\n\u003ctd\u003eInverting or non-inverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e48 ±11 VDC or 100–240 VAC; 24 ±4 VDC option (10 W); DC over coax on 10–25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e85 W (10 W, DC) to 540 VA (80 W, AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C (10–50 W); -40 to +55 °C (60–80 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.5 x 6 x 3.8 to 6.1 in (267 x 152 x 97 to 155 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e9.3 to 12.4 lb (4.2 to 5.6 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eC-band VSAT and SCPC terminals\u003c\/li\u003e\n\u003cli\u003eGovernment and defense networks\u003c\/li\u003e\n\u003cli\u003eAir traffic control links\u003c\/li\u003e\n\u003cli\u003eRural and backhaul telecom\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%202%20C-Band%2010%E2%80%9380W%20GaAs%20Intelligent%20BUC\u0026amp;mpn=IBUC%202%2010%E2%80%9380W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109433711,"sku":"TRS-IBUC2-C-10-80W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-2-gaas-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-2e-c-band-10-20w-buc","title":"Terrasat IBUC 2e C-Band 10–20W GaAs Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 2e is the low-energy version of the IBUC 2: a 10 W to 20 W C-band Intelligent BUC powered entirely from the modem over the IFL coax. It draws less DC power than the IBUC 2, which lets modem-powered VSAT terminals run a higher-power BUC without a separate supply at the antenna, and keeps the full IBUC M\u0026amp;C feature set.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e10, 15 or 20 W P1dB (+40 to +43 dBm min)\u003c\/li\u003e\n\u003cli\u003ePowered over the IFL coax: no separate supply at the antenna\u003c\/li\u003e\n\u003cli\u003eLower power draw than the IBUC 2 (65 W at 10 W output)\u003c\/li\u003e\n\u003cli\u003eStandard, extended, full or INSAT C-band\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 2e 10–20W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 2e 10–20W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard C-band 5.850–6.425 GHz; Extended C-band 5.850–6.650 GHz; Full C-band 5.850–6.725 GHz; INSAT C-band 6.725–7.025 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1525 MHz (standard C) to 950–1825 MHz (full C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power (P1dB)\u003c\/th\u003e\n\u003ctd\u003e10 W +40 dBm; 15 W +41.8 dBm; 20 W +43 dBm (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaAs SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e71–74 dB min (standard); 60–63 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eCPR-137G waveguide or Type N female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral sense\u003c\/th\u003e\n\u003ctd\u003eInverting or non-inverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eDC over the IFL coax only: 18–75 VDC (10 W); 48 ±11 VDC (15 W, 20 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e65 W (10 W); 100 W (15 W); 120 W (20 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.5 x 6 x 3.8 in (10 W); 10.5 x 6 x 5.2 in (15–20 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e9.3 lb (4.2 kg) to 10.8 lb (4.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eModem-powered C-band VSAT terminals\u003c\/li\u003e\n\u003cli\u003eRemote sites with limited power\u003c\/li\u003e\n\u003cli\u003eEnterprise and government VSAT networks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%202e%20C-Band%2010%E2%80%9320W%20GaAs%20Intelligent%20BUC\u0026amp;mpn=IBUC%202e%2010%E2%80%9320W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109466479,"sku":"TRS-IBUC2E-C-10-20W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-2e-gaas-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-2g-c-band-100w-buc","title":"Terrasat IBUC 2G C-Band 100W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 2G puts a 100 W gallium nitride (GaN) amplifier in the compact IBUC 2 housing. It delivers +50 dBm saturated and +47 dBm linear output across the C-band (a 125 W version reaches +51 dBm), with the efficiency and long life of GaN, and suits multicarrier and high-throughput C-band terminals where antenna-mounted power and weight matter.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e100 W PSat \/ 50 W PLin (+50 \/ +47 dBm); 125 W version available\u003c\/li\u003e\n\u003cli\u003eGaN amplifier in the compact IBUC 2 housing (13.5 lb)\u003c\/li\u003e\n\u003cli\u003eStandard, Palapa, extended, full or INSAT C-band\u003c\/li\u003e\n\u003cli\u003eMulticarrier ready: 19 dB min NPR\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; FSK on the IFL; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 2G 100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 2G 100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard C-band 5.850–6.425 GHz; Extended C-band 5.850–6.650 GHz; Full C-band 5.850–6.725 GHz; Palapa C-band 6.425–6.725 GHz; INSAT C-band 6.725–7.025 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1750 MHz depending on band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e100 W: +50 dBm PSat (typ), +47 dBm PLin (min); 125 W: +51 dBm PSat, +49 dBm PLin; INSAT 0.5 dB lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e81 dB min (standard); 70 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω or TNC 50 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eCPR-137G waveguide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral sense\u003c\/th\u003e\n\u003ctd\u003eInverting or non-inverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e420–490 VA at PLin; 510–560 VA at PSat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector; FSK on the TX IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.5 x 6.0 x 6.1 in (267 x 152 x 155 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e13.5 lb (6.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulticarrier C-band uplinks\u003c\/li\u003e\n\u003cli\u003eTeleport and hub terminals\u003c\/li\u003e\n\u003cli\u003eMaritime and government C-band networks\u003c\/li\u003e\n\u003cli\u003eCellular backhaul\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%202G%20C-Band%20100W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%202G%20100W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109499247,"sku":"TRS-IBUC2G-C-100W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-2g-gan-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-r-c-band-100-400w-buc","title":"Terrasat IBUC R C-Band 100–400W GaAs Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC R is the high-power GaAs member of the IBUC family, from 100 W to 400 W at C-band, in the original IBUC housing with an upgraded RJ45 M\u0026amp;C interface. It suits higher-power terminals in telecom, defense, maritime and broadcast, and runs from DC or AC power on the 100 W to 200 W models.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e100 W to 400 W P1dB (+50 to +56 dBm min)\u003c\/li\u003e\n\u003cli\u003eStandard, Palapa, extended or INSAT C-band\u003c\/li\u003e\n\u003cli\u003eDC (42–60 V) or AC power on 100–200 W models\u003c\/li\u003e\n\u003cli\u003eRJ45 Ethernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy, internal 10 MHz reference and WGS-compatible options\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC R 100–400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC R 100–400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard C-band 5.850–6.425 GHz; Extended C-band 5.850–6.650 GHz; Palapa C-band 6.425–6.725 GHz; INSAT C-band 6.725–7.025 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1750 MHz depending on band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power (P1dB)\u003c\/th\u003e\n\u003ctd\u003e100 W +50 dBm; 125 W +51; 150 W +51.8; 175 W +52.4; 200 W +53; 400 W +56 dBm (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaAs SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e81–84 dB min (standard); 70–76 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω or TNC 50 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eCPR-137G waveguide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral sense\u003c\/th\u003e\n\u003ctd\u003eInverting or non-inverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e42–60 VDC (100–200 W); 100–240 VAC (100–125 W); 200–240 VAC (150–400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e700 W \/ 800 VA (100 W) to 2,350 VA (400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector; FSK on the TX IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e16.2 x 10 x 7.6 in (100–200 W); 29 x 15 x 10.1 in (400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e32–33 lb (100–200 W); 83 lb \/ 37.6 kg (400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-power C-band uplinks\u003c\/li\u003e\n\u003cli\u003eBroadcast and contribution\u003c\/li\u003e\n\u003cli\u003eMaritime and defense terminals\u003c\/li\u003e\n\u003cli\u003eTelecom trunking\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20R%20C-Band%20100%E2%80%93400W%20GaAs%20Intelligent%20BUC\u0026amp;mpn=IBUC%20R%20100%E2%80%93400W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109532015,"sku":"TRS-IBUCR-C-100-400W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-r-gaas-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-g-c-band-200-500w-buc","title":"Terrasat IBUC G C-Band 200–500W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC G brings high-power GaN amplification to an antenna-mounted C-band BUC, with 200 W, 400 W and 500 W models (+53 to +57 dBm saturated) that support multicarrier operation across the full C-band. Linear power of up to +54 dBm makes it an alternative to a TWTA for broadband, maritime, broadcast and hub uplinks, without the waveguide losses of an indoor amplifier.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e200 W, 400 W and 500 W PSat (+53, +56, +57 dBm)\u003c\/li\u003e\n\u003cli\u003eLinear power to +54 dBm with 19 dB min NPR\u003c\/li\u003e\n\u003cli\u003eStandard, Palapa, extended, full or INSAT C-band\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy with Eco-Mode\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; FSK on the IFL; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC G 200–500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC G 200–500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard C-band 5.850–6.425 GHz; Extended C-band 5.850–6.650 GHz; Full C-band 5.850–6.725 GHz; Palapa C-band 6.425–6.725 GHz; INSAT C-band 6.725–7.025 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1750 MHz depending on band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e200 W: +53 dBm PSat, +50 dBm PLin; 400 W: +56 \/ +53 dBm; 500 W: +57 \/ +54 dBm (standard C; other bands 0.5 dB lower)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e82–84 dB min (standard); 73–77 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω or TNC 50 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eCPR-137G waveguide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral sense\u003c\/th\u003e\n\u003ctd\u003eInverting or non-inverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (200 W); 200–240 VAC (400–500 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e750–950 VA (200 W); 1,450–2,100 VA (400–500 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector; FSK on the TX IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e16.2 x 10 x 7.6 in (200 W); 24 x 10 x 7.4 in (400–500 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e33 lb \/ 14.9 kg (200 W); 40 lb \/ 18 kg (400–500 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulticarrier C-band hub and teleport uplinks\u003c\/li\u003e\n\u003cli\u003eBroadcast and DTH contribution\u003c\/li\u003e\n\u003cli\u003eMaritime and offshore networks\u003c\/li\u003e\n\u003cli\u003eTWTA replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20G%20C-Band%20200%E2%80%93500W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%20G%20200%E2%80%93500W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109564783,"sku":"TRS-IBUCG-C-200-500W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-g-200-500w-c-band-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-g-c-band-800w-buc","title":"Terrasat IBUC G C-Band 800W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC G 800 W is the highest-power C-band unit in the IBUC range: +59 dBm saturated and +56 dBm linear from a single antenna-mounted GaN amplifier. It replaces high-power TWTA and klystron systems on teleport and broadcast uplinks, and supports 1+1 and 2+1 redundancy and Terrasat's load switch kit.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e800 W PSat (+59 dBm), +56 dBm PLin\u003c\/li\u003e\n\u003cli\u003eGaN amplifier with 19 dB min NPR for multicarrier operation\u003c\/li\u003e\n\u003cli\u003eStandard, extended, full or INSAT C-band\u003c\/li\u003e\n\u003cli\u003e1+1 and 2+1 redundancy; load switch kit\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened Core M\u0026amp;C with IPv6\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC G 800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC G 800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard C-band 5.850–6.425 GHz; Extended C-band 5.850–6.650 GHz; Full C-band 5.850–6.725 GHz; INSAT C-band 6.725–7.025 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1825 MHz depending on band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e+59 dBm PSat (typ), +56 dBm PLin (min) in standard C-band; 0.7 dB lower in other bands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e85 dB min (standard); 79 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eCPR-137G waveguide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral sense\u003c\/th\u003e\n\u003ctd\u003eInverting or non-inverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e200–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e2,400–2,600 VA at PLin; 3,100–3,350 VA at PSat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector; FSK on the TX IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e29 x 15 x 10.1 in (737 x 381 x 257 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e83 lb (38 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-power C-band teleport uplinks\u003c\/li\u003e\n\u003cli\u003eBroadcast and DTH uplinks\u003c\/li\u003e\n\u003cli\u003eTWTA and klystron replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20G%20C-Band%20800W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%20G%20800W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109597551,"sku":"TRS-IBUCG-C-800W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-g-gan-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-2-x-band-10-40w-buc","title":"Terrasat IBUC 2 X-Band 10–40W GaAs Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 2 X-band is a compact Intelligent BUC for 7.9–8.4 GHz military and government satcom, with GaAs amplifiers from 10 W to 40 W. It is a common choice for X-band manpack, vehicle and fixed terminals on WGS and other X-band satellites, with a WGS-compatible lower-gain version and Ethernet, SNMP and web M\u0026amp;C.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e10, 20, 25 or 40 W P1dB (+40 to +46 dBm min)\u003c\/li\u003e\n\u003cli\u003eX-band 7.9–8.4 GHz; 950–1450 MHz IF\u003c\/li\u003e\n\u003cli\u003eAC or DC power; 24 VDC and DC-over-coax options on lower-power models\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy and internal 10 MHz reference options\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 2 10–40W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 2 10–40W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003e7.9–8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO frequency\u003c\/th\u003e\n\u003ctd\u003e6.95 GHz, non-inverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power (P1dB)\u003c\/th\u003e\n\u003ctd\u003e10 W +40 dBm; 20 W +43; 25 W +44; 40 W +46 dBm (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLinear power (PLin)\u003c\/th\u003e\n\u003ctd\u003e39.5 \/ 42.5 \/ 43.5 \/ 45 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaAs SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e71–77 dB min (standard); 60–66 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eCPR-112G waveguide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e48 ±11 VDC or 100–240 VAC; 24 ±4 VDC option (10 W); DC over coax on 10–20 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e90 W (10 W, DC) to 350 VA (40 W, AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.5 x 6 x 3.8 to 6.1 in (267 x 152 x 97 to 155 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e9.3 lb (4.2 kg) to about 12 lb (5.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eX-band military and government terminals\u003c\/li\u003e\n\u003cli\u003eWGS and Skynet ground terminals\u003c\/li\u003e\n\u003cli\u003eTransportable and vehicle-mount X-band systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%202%20X-Band%2010%E2%80%9340W%20GaAs%20Intelligent%20BUC\u0026amp;mpn=IBUC%202%2010%E2%80%9340W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109630319,"sku":"TRS-IBUC2-X-10-40W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-2-gaas-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-2g-x-band-50-100w-buc","title":"Terrasat IBUC 2G X-Band 50–100W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 2G X-band packs 50 W or 100 W of GaN power (+47 or +50 dBm saturated) into the compact IBUC 2 housing. Its linear output supports multicarrier X-band operation from a 13.5 lb antenna-mounted unit, making it a fit for WGS terminals and X-band hubs that need more power without a heavier amplifier.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e50 W or 100 W PSat (+47 \/ +50 dBm); +44 \/ +47 dBm PLin\u003c\/li\u003e\n\u003cli\u003eGaN amplifier in the compact IBUC 2 housing (13.5 lb)\u003c\/li\u003e\n\u003cli\u003eMulticarrier ready: 19 dB min NPR\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version with IPv6\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 2G 50–100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 2G 50–100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003e7.9–8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO frequency\u003c\/th\u003e\n\u003ctd\u003e6.95 GHz, non-inverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e50 W: +47 dBm PSat (typ), +44 dBm PLin (min); 100 W: +50 \/ +47 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e78–81 dB min (standard); 67–70 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eCPR-112G waveguide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e220–260 VA (50 W); 440–520 VA (100 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.5 x 6 x 6.1 in (267 x 152 x 155 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e13.5 lb (6.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWGS and military X-band terminals\u003c\/li\u003e\n\u003cli\u003eX-band hub and gateway uplinks\u003c\/li\u003e\n\u003cli\u003eTransportable X-band systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%202G%20X-Band%2050%E2%80%93100W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%202G%2050%E2%80%93100W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109663087,"sku":"TRS-IBUC2G-X-50-100W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-2g-gan-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-g-x-band-150-400w-buc","title":"Terrasat IBUC G X-Band 150–400W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC G X-band delivers 150 W, 200 W or 400 W of GaN power (+51.8 to +56 dBm saturated) from an antenna-mounted unit. It gives X-band hubs and gateway terminals TWTA-class linear power for multicarrier operation, with lower power consumption and no long waveguide run from an indoor amplifier.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e150 W, 200 W and 400 W PSat (+51.8, +53, +56 dBm)\u003c\/li\u003e\n\u003cli\u003eLinear power to +53 dBm with 19 dB min NPR\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy with Eco-Mode\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eReplaces earlier IBUC R X-band models\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC G 150–400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC G 150–400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003e7.9–8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO frequency\u003c\/th\u003e\n\u003ctd\u003e6.95 GHz, non-inverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e150 W: +51.8 dBm PSat, +48.8 dBm PLin; 200 W: +53 \/ +50 dBm; 400 W: +56 \/ +53 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e82–84 dB min (standard); 72–76 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional (TNC on 400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eCPR-112G waveguide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (150–200 W); 200–240 VAC (400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e700–1,000 VA (150–200 W); 1,800–2,200 VA (400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e16.2 x 10 x 7.6 in (150–200 W); 24 x 10 x 7.4 in (400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e33 lb \/ 14.9 kg (150–200 W); 40 lb \/ 18 kg (400 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eX-band hub and gateway uplinks\u003c\/li\u003e\n\u003cli\u003eMilitary teleports\u003c\/li\u003e\n\u003cli\u003eTWTA replacement at X-band\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20G%20X-Band%20150%E2%80%93400W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%20G%20150%E2%80%93400W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109695855,"sku":"TRS-IBUCG-X-150-400W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-g-gan-intelligent-buc-2.png?v=1793925080"},{"product_id":"terrasat-ibuc-g-x-band-700w-buc","title":"Terrasat IBUC G X-Band 700W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC G 700 W is the highest-power X-band IBUC: +58.5 dBm saturated and +55.5 dBm linear from one antenna-mounted GaN unit. It is sized for X-band teleports and military gateways that previously needed a high-power TWTA, with Terrasat's IBUC M\u0026amp;C and an optional Cyber Hardened controller.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e700 W PSat (+58.5 dBm), +55.5 dBm PLin\u003c\/li\u003e\n\u003cli\u003eGaN amplifier with 19 dB min NPR for multicarrier use\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version with IPv6\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC G 700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC G 700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003e7.9–8.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO frequency\u003c\/th\u003e\n\u003ctd\u003e6.95 GHz, non-inverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e+58.5 dBm PSat (typ), +55.5 dBm PLin (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e85 dB min (standard); 79 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eCPR-112G waveguide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e200–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e3,300 VA at PLin; 4,000 VA at PSat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e737 x 381 x 257 mm (29 x 15 x 10.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e83 lb (38 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eX-band teleport and gateway uplinks\u003c\/li\u003e\n\u003cli\u003eMilitary high-power terminals\u003c\/li\u003e\n\u003cli\u003eTWTA replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20G%20X-Band%20700W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%20G%20700W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109728623,"sku":"TRS-IBUCG-X-700W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-g-gan-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-3-ku-band-8-16w-buc","title":"Terrasat IBUC 3 Ku-Band 8–16W GaAs Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 3 is a full-featured Ku-band Intelligent BUC in a small 5.6 lb housing, built for mobility terminals, very small apertures and flat-panel antennas where size and weight count. It comes in 8 W and 16 W GaAs versions, in standard or full Ku-band, and can be powered over the IFL coax.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 W or 16 W P1dB (+39 \/ +42 dBm min)\u003c\/li\u003e\n\u003cli\u003e7 x 5 x 4 in, 5.6 lb (2.5 kg)\u003c\/li\u003e\n\u003cli\u003eStandard or full Ku-band\u003c\/li\u003e\n\u003cli\u003eDC powered, with or without power over the IFL coax\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 3 8–16W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 3 8–16W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard Ku-band 14.00–14.50 GHz; Full Ku-band 13.75–14.50 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz (standard); 950–1700 MHz (full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power (P1dB)\u003c\/th\u003e\n\u003ctd\u003e8 W +39 dBm; 16 W +42 dBm (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaAs SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e70–73 dB min (standard); 59–62 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR75 cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e8 W: 20–36 or 38–76 VDC; 16 W: 38–76 VDC; power over coax available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e70 W (8 W); 135 W (16 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7 x 5 x 4 in (178 x 127 x 102 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e5.6 lb (2.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eKu-band mobility and comms-on-the-move terminals\u003c\/li\u003e\n\u003cli\u003eFlat-panel and small-aperture antennas\u003c\/li\u003e\n\u003cli\u003eFlyaway and manpack VSAT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%203%20Ku-Band%208%E2%80%9316W%20GaAs%20Intelligent%20BUC\u0026amp;mpn=IBUC%203%208%E2%80%9316W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109794159,"sku":"TRS-IBUC3-KU-8-16W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-3-8-16w-ku-band-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-3g-ku-band-25-40w-buc","title":"Terrasat IBUC 3G Ku-Band 25–40W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 3G puts GaN amplifiers of 25 W, 30 W or 40 W into the small IBUC 3 housing: 6.5 lb for up to +46 dBm saturated output. It brings higher Ku-band power to mobility, flyaway and flat-panel terminals without the size and weight of a conventional high-power BUC, in standard, full or low Ku-band.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e25, 30 or 40 W PSat (+44 to +46 dBm); +41 to +43 dBm PLin\u003c\/li\u003e\n\u003cli\u003e7 x 5 x 4 in, 6.5 lb (3 kg)\u003c\/li\u003e\n\u003cli\u003eStandard, full or low Ku-band\u003c\/li\u003e\n\u003cli\u003e38–76 VDC power\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; FSK on the IFL; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 3G 25–40W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 3G 25–40W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard Ku-band 14.00–14.50 GHz; Full Ku-band 13.75–14.50 GHz; Low Ku-band 12.75–13.25 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz (standard, low); 950–1700 MHz (full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e25 W: +44 dBm PSat, +41 dBm PLin; 30 W: +45 \/ +42 dBm; 40 W: +46 \/ +43 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e75–77 dB min (standard); 64–66 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω or TNC 50 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR75 cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e38–76 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e150–205 W (25 W) to 205–265 W (40 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector; FSK on the TX IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7 x 5 x 4 in (178 x 127 x 102 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e6.5 lb (3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-throughput Ku-band mobility terminals\u003c\/li\u003e\n\u003cli\u003eFlyaway and transportable VSAT\u003c\/li\u003e\n\u003cli\u003eFlat-panel and small-aperture antennas\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%203G%20Ku-Band%2025%E2%80%9340W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%203G%2025%E2%80%9340W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109826927,"sku":"TRS-IBUC3G-KU-25-40W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-3g-25-40w-ku-band-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-2-ku-band-4-40w-buc","title":"Terrasat IBUC 2 Ku-Band 4–40W GaAs Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 2 Ku-band is a compact Intelligent BUC with GaAs amplifiers from 4 W to 25 W, plus a 40 W model for low Ku-band. It is a long-standing choice for VSAT, SCPC and network terminals in telecom, defense and government, with Ethernet, SNMP and web M\u0026amp;C and AC, DC or power-over-coax options.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4 W to 25 W P1dB (+36 to +44 dBm); 40 W (+46 dBm) for low Ku-band\u003c\/li\u003e\n\u003cli\u003eStandard, full or low Ku-band\u003c\/li\u003e\n\u003cli\u003eAC or DC power; 24 VDC and DC-over-coax options on lower-power models\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy and internal 10 MHz reference options\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 2 4–40W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 2 4–40W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard Ku-band 14.00–14.50 GHz; Full Ku-band 13.75–14.50 GHz; Low Ku-band 12.75–13.25 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz (standard, low); 950–1700 MHz (full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power (P1dB)\u003c\/th\u003e\n\u003ctd\u003e8 W +39 dBm; 16 W +42; 20 W +43; 25 W +44 dBm (min); 40 W +46 dBm (low Ku-band only); 4 W model available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaAs SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e70–77 dB min (standard); 59–66 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR75 cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e48 ±11 VDC or 100–240 VAC; 24 ±4 VDC option (8 W); DC over coax on 8–16 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e77 W (4 W, DC) to 420 VA (40 W, AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C (lower power); -40 to +55 °C (higher power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.5 x 6 x 3.8 to 6.1 in (267 x 152 x 97 to 155 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e9.3 lb (4.2 kg) to about 12.5 lb (5.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eKu-band VSAT and SCPC terminals\u003c\/li\u003e\n\u003cli\u003eEnterprise and government networks\u003c\/li\u003e\n\u003cli\u003eCellular backhaul\u003c\/li\u003e\n\u003cli\u003eOil and gas remote sites\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%202%20Ku-Band%204%E2%80%9340W%20GaAs%20Intelligent%20BUC\u0026amp;mpn=IBUC%202%204%E2%80%9340W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109859695,"sku":"TRS-IBUC2-KU-4-40W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-2-gaas-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-2e-ku-band-4-16w-buc","title":"Terrasat IBUC 2e Ku-Band 4–16W GaAs Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 2e Ku-band is a modem-powered Intelligent BUC: 8 W or 16 W (and a 4 W version) of GaAs output drawing all its DC power over the IFL coax. It uses less power than the IBUC 2, so VSAT modems can drive a higher-power BUC without a separate supply at the antenna.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 W or 16 W P1dB (+39 \/ +42 dBm min); 4 W version available\u003c\/li\u003e\n\u003cli\u003ePowered over the IFL coax: no separate supply at the antenna\u003c\/li\u003e\n\u003cli\u003e65 W draw at 8 W output\u003c\/li\u003e\n\u003cli\u003eStandard, full or low Ku-band\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; FSK on the IFL; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 2e 4–16W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 2e 4–16W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard Ku-band 14.00–14.50 GHz; Full Ku-band 13.75–14.50 GHz; Low Ku-band 12.75–13.25 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz (standard, low); 950–1700 MHz (full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power (P1dB)\u003c\/th\u003e\n\u003ctd\u003e8 W +39 dBm; 16 W +42 dBm (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaAs SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e70–73 dB min (standard); 59–62 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR75 cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eDC over the IFL coax only: 18–75 VDC (8 W); 37–60 VDC (16 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e65 W (8 W); 120 W (16 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector; FSK on the TX IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.5 x 6 x 3.8 in (8 W); 10.5 x 6 x 5.2 in (16 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e9.3 lb (4.2 kg); 10.8 lb (4.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eModem-powered Ku-band VSAT terminals\u003c\/li\u003e\n\u003cli\u003eRemote and solar-powered sites\u003c\/li\u003e\n\u003cli\u003eEnterprise VSAT networks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%202e%20Ku-Band%204%E2%80%9316W%20GaAs%20Intelligent%20BUC\u0026amp;mpn=IBUC%202e%204%E2%80%9316W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109892463,"sku":"TRS-IBUC2E-KU-4-16W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-2e-gaas-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-2g-ku-band-25-80w-buc","title":"Terrasat IBUC 2G Ku-Band 25–80W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 2G Ku-band brings GaN power from 25 W to 80 W (+44 to +49 dBm saturated) to the compact IBUC 2 housing. Terrasat's implementation needs only 2 dB of backoff from saturation to linear power at 80 W, so more of the rated power is usable for multicarrier and high-throughput Ku-band carriers.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e25, 40, 50, 60 or 80 W PSat (+44 to +49 dBm)\u003c\/li\u003e\n\u003cli\u003eLinear power to +46 dBm; only 2 dB backoff at 80 W\u003c\/li\u003e\n\u003cli\u003eStandard, full or low Ku-band\u003c\/li\u003e\n\u003cli\u003eAC or DC power\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; FSK on the IFL; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 2G 25–80W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 2G 25–80W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard Ku-band 14.00–14.50 GHz; Full Ku-band 13.75–14.50 GHz; Low Ku-band 12.75–13.25 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz (standard, low); 950–1700 MHz (full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003ePSat (typ) \/ PLin (min): 25 W +44 \/ +41 dBm; 40 W +46 \/ +43; 50 W +47 \/ +44 (standard and full Ku only); 60 W +48 \/ +45; 80 W +49 \/ +46 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e75–80 dB min (standard); 64–69 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR75 cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e37–60 VDC or 100–240 VAC (80 W: AC only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e150 W \/ 170 VA (25 W) to 475–570 VA (80 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector; FSK on the TX IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.5 x 6 x 6.1 in (267 x 152 x 155 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e13.5 lb (6.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulticarrier Ku-band uplinks\u003c\/li\u003e\n\u003cli\u003eHigh-throughput VSAT hubs\u003c\/li\u003e\n\u003cli\u003eMaritime and enterprise Ku-band networks\u003c\/li\u003e\n\u003cli\u003eSNG and broadcast trucks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%202G%20Ku-Band%2025%E2%80%9380W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%202G%2025%E2%80%9380W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109925231,"sku":"TRS-IBUC2G-KU-25-80W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-2g-gan-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-r-ku-band-60w-buc","title":"Terrasat IBUC R Ku-Band 60W GaAs Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC R Ku-band is a 60 W GaAs Intelligent BUC (+47.8 dBm) in the original IBUC housing with an upgraded RJ45 M\u0026amp;C interface and an optional Cyber Hardened Core controller. It runs from AC or DC power and supports 1+1 and 2+1 redundancy for higher-power Ku-band terminals in telecom, defense, maritime and broadcast.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e60 W P1dB (+47.8 dBm typ)\u003c\/li\u003e\n\u003cli\u003eStandard or full Ku-band\u003c\/li\u003e\n\u003cli\u003eAC (100–240 V) or DC (42–60 V) power\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy with Eco-Mode and 2+1 redundancy\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; FSK on the IFL; optional Cyber Hardened Core\u003c\/li\u003e\n\u003cli\u003eWGS-compatible version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC R 60W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC R 60W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard Ku-band 14.00–14.50 GHz; Full Ku-band 13.75–14.50 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz (standard); 950–1700 MHz (full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power (P1dB)\u003c\/th\u003e\n\u003ctd\u003e+47.8 dBm typ (standard Ku); +47.5 dBm (full Ku)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaAs SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e79 dB min (standard); 68 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω or TNC 50 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR75 cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e42–60 VDC or 100–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e550 W (DC); 600 VA (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector; FSK on the TX IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e12.2 x 7.2 x 6.5 in (DC); 12.2 x 7.2 x 6.8 in (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e18.5 lb \/ 8.4 kg (DC); 19.5 lb \/ 8.8 kg (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigher-power Ku-band VSAT and SCPC\u003c\/li\u003e\n\u003cli\u003eBroadcast and SNG uplinks\u003c\/li\u003e\n\u003cli\u003eMaritime and defense terminals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20R%20Ku-Band%2060W%20GaAs%20Intelligent%20BUC\u0026amp;mpn=IBUC%20R%2060W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109957999,"sku":"TRS-IBUCR-KU-60W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-r-gaas-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-g-ku-band-100w-buc","title":"Terrasat IBUC G Ku-Band 100W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC G 100 W Ku-band delivers +50 dBm saturated and +47 dBm linear from a compact 19.5 lb GaN unit, across standard, full or low Ku-band. It bridges the IBUC 2G and the larger IBUC G models for multicarrier Ku-band terminals that need 100 W at the antenna.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e100 W PSat (+50 dBm), +47 dBm PLin\u003c\/li\u003e\n\u003cli\u003eCompact 12.2 x 7.2 x 6.8 in housing, 19.5 lb\u003c\/li\u003e\n\u003cli\u003eStandard, full or low Ku-band\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version with IPv6\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC G 100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC G 100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard Ku-band 14.00–14.50 GHz; Full Ku-band 13.75–14.50 GHz; Low Ku-band 12.75–13.25 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz (standard, low); 950–1700 MHz (full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e+50 dBm PSat (typ), +47 dBm PLin (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e81 dB min (standard); 70 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω or TNC 50 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR75 cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e550 VA at PLin; 650 VA at PSat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e12.2 x 7.2 x 6.8 in (310 x 183 x 173 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e19.5 lb (8.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulticarrier Ku-band uplinks\u003c\/li\u003e\n\u003cli\u003eMaritime and enterprise hubs\u003c\/li\u003e\n\u003cli\u003eSNG and broadcast uplinks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20G%20Ku-Band%20100W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%20G%20100W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979109990767,"sku":"TRS-IBUCG-KU-100W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-g-gan-intelligent-buc-3.png?v=1793925080"},{"product_id":"terrasat-ibuc-g-ku-band-150-200w-buc","title":"Terrasat IBUC G Ku-Band 150–200W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC G 150 W and 200 W Ku-band units deliver +51.8 and +53 dBm saturated from an antenna-mounted GaN amplifier. Terrasat keeps the backoff to linear power to about 3 dB, giving up to +50 dBm of linear power for network hubs and broadcast uplinks.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e150 W or 200 W PSat (+51.8 \/ +53 dBm)\u003c\/li\u003e\n\u003cli\u003e+48.8 \/ +50 dBm PLin with 19 dB min NPR\u003c\/li\u003e\n\u003cli\u003eStandard, full or low Ku-band\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy with Eco-Mode\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version with IPv6\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC G 150–200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC G 150–200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard Ku-band 14.00–14.50 GHz; Full Ku-band 13.75–14.50 GHz; Low Ku-band 12.75–13.25 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz (standard, low); 950–1700 MHz (full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e150 W: +51.8 dBm PSat, +48.8 dBm PLin; 200 W: +53 \/ +50 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e83 dB min (standard); 72–73 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω or TNC 50 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR75 cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e200–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1,080 VA (150 W) \/ 1,300 VA (200 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e23 x 10 x 7.4 in (584 x 254 x 188 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e37 lb (17 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eKu-band hub and teleport uplinks\u003c\/li\u003e\n\u003cli\u003eBroadcast and DTH contribution\u003c\/li\u003e\n\u003cli\u003eMaritime and offshore networks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20G%20Ku-Band%20150%E2%80%93200W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%20G%20150%E2%80%93200W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110023535,"sku":"TRS-IBUCG-KU-150-200W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-g-gan-intelligent-buc-2.png?v=1793925080"},{"product_id":"terrasat-ibuc-g-ku-band-300-400w-buc","title":"Terrasat IBUC G Ku-Band 300–400W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC G 300 W and 400 W Ku-band units produce +51.8 and +53 dBm of linear power (+54.8 and +56 dBm saturated) from one antenna-mounted GaN amplifier. They are built for maritime, broadcast and network hub uplinks that need TWTA-class power at Ku-band.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e300 W or 400 W PSat (+54.8 \/ +56 dBm)\u003c\/li\u003e\n\u003cli\u003e+51.8 \/ +53 dBm PLin with 19 dB min NPR\u003c\/li\u003e\n\u003cli\u003eStandard, full or low Ku-band\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy with Eco-Mode\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version with IPv6\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC G 300–400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC G 300–400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard Ku-band 14.00–14.50 GHz; Full Ku-band 13.75–14.50 GHz; Low Ku-band 12.75–13.25 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz (standard, low); 950–1700 MHz (full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e300 W: +54.8 dBm PSat, +51.8 dBm PLin; 400 W: +56 \/ +53 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e83 dB min (standard); 75–76 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω or TNC 50 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR75 cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e200–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e1,900–2,000 VA at PLin; 2,500–2,600 VA at PSat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e29 x 15 x 10.1 in (737 x 381 x 257 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e83 lb (38 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-power Ku-band teleport uplinks\u003c\/li\u003e\n\u003cli\u003eBroadcast and DTH uplinks\u003c\/li\u003e\n\u003cli\u003eTWTA replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20G%20Ku-Band%20300%E2%80%93400W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%20G%20300%E2%80%93400W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110056303,"sku":"TRS-IBUCG-KU-300-400W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-g-gan-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-g-ku-band-800w-buc","title":"Terrasat IBUC G Ku-Band 800W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC G 800 W is the most powerful Ku-band IBUC: +59 dBm saturated and +56 dBm linear from a single GaN unit, powered from three 200–240 VAC inputs. It replaces high-power TWTA and klystron amplifiers on Ku-band teleport and broadcast uplinks.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e800 W PSat (+59 dBm), +56 dBm PLin\u003c\/li\u003e\n\u003cli\u003eGaN amplifier with 19 dB min NPR for multicarrier operation\u003c\/li\u003e\n\u003cli\u003eStandard, full or low Ku-band\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened version with IPv6\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC G 800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC G 800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eStandard Ku-band 14.00–14.50 GHz; Full Ku-band 13.75–14.50 GHz; Low Ku-band 12.75–13.25 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1450 MHz (standard, low); 950–1700 MHz (full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003e+59 dBm PSat (typ), +56 dBm PLin (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA; 19 dB min NPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e83 dB min (standard); 79 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR75 cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e200–240 VAC, 3 inputs, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e4,500 VA at PLin; 5,500 VA at PSat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e33 x 15 x 10.1 in (838 x 381 x 257 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e99.6 lb (45.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-power Ku-band teleport uplinks\u003c\/li\u003e\n\u003cli\u003eBroadcast and DTH uplinks\u003c\/li\u003e\n\u003cli\u003eTWTA and klystron replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20G%20Ku-Band%20800W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%20G%20800W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110089071,"sku":"TRS-IBUCG-KU-800W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-g-gan-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-2g-ka-band-20-50w-buc","title":"Terrasat IBUC 2G Ka-Band 20–50W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC 2G Ka-band is a compact GaN Intelligent BUC from 20 W to 50 W (+43 to +47 dBm saturated), built in single-band, dual-band, tri-band and quad-band versions. The multiband models switch between Ka sub-bands in software, covering 27.5 to 31.0 GHz, so one terminal can work commercial, military and multi-orbit Ka-band networks.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e20, 25, 40 or 50 W PSat (+43 to +47 dBm); +40 to +44 dBm PLin\u003c\/li\u003e\n\u003cli\u003eSingle, dual, tri or quad-band (27.5–31.0 GHz) versions\u003c\/li\u003e\n\u003cli\u003eSoftware-selectable sub-bands on multiband models\u003c\/li\u003e\n\u003cli\u003eAC or DC power\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened Core\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version; 1+1 and 2+1 redundancy\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 2G 20–50W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC 2G 20–50W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eSingle band: 29.0–30.0 or 30.0–31.0 GHz; dual band: 29.0–30.0 and 30.0–31.0 GHz; tri-band: 27.5–28.5, 28.25–29.25 and 29.0–30.0 GHz; quad-band: all four sub-bands, 27.5–31.0 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e950–1950 MHz or 1.0–2.0 GHz (any RF with any IF on multiband models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003ePSat (typ) \/ PLin (min): 20 W +43 \/ +40 dBm; 25 W +44 \/ +41; 40 W +46 \/ +43; 50 W +47 \/ +44 dBm (quad-band to 40 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e74–78 dB min (standard); 63–67 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional (TNC on single band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR28 UG cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e48 ±11 VDC (single, dual band) or 37–60 VDC (tri, quad band); 100–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e135–180 W (20 W, DC) to 360–480 VA (50 W, AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector; FSK on the TX IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.5 x 6 x 5.7 to 6.5 in (267 x 152 x 145 to 165 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e11.5 lb \/ 5.2 kg (DC); 12.8 lb \/ 5.8 kg (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-orbit Ka-band terminals (GEO, MEO, LEO)\u003c\/li\u003e\n\u003cli\u003eMilitary Ka-band (WGS) and commercial HTS\u003c\/li\u003e\n\u003cli\u003eKa-band VSAT and gateway terminals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%202G%20Ka-Band%2020%E2%80%9350W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%202G%2020%E2%80%9350W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110121839,"sku":"TRS-IBUC2G-KA-20-50W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-2g-gan-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-ibuc-g-ka-band-60-100w-buc","title":"Terrasat IBUC G Ka-Band 60–100W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC G Ka-band 60 W to 100 W units put up to +50 dBm saturated into a compact antenna-mounted GaN housing, avoiding the losses of long Ka-band waveguide runs. Single-band models include a 27.5–30.0 GHz wide-conversion option; dual, tri and quad-band models switch sub-bands in software.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e80 W or 100 W PSat (+49 \/ +50 dBm); quad-band 60 W or 80 W\u003c\/li\u003e\n\u003cli\u003eSingle, dual, tri or quad-band versions; wide-conversion single-band option\u003c\/li\u003e\n\u003cli\u003eCompact 19.5 lb housing (single, dual and quad band)\u003c\/li\u003e\n\u003cli\u003eGaN efficiency for lower power consumption\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened Core\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC G 60–100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC G 60–100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eSingle band: 29.0–30.0 or 30.0–31.0 GHz; dual band: 29.0–30.0 and 30.0–31.0 GHz; tri-band: 27.5–28.5, 28.25–29.25 and 29.0–30.0 GHz; quad-band: all four sub-bands, 27.5–31.0 GHz; single band also 29.5–30.0 GHz and 27.5–30.0 GHz wide conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e1.0–2.0 GHz or 950–1950 MHz; 1.25–3.75 GHz for wide conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003ePSat (typ) \/ PLin (min): 60 W +48 \/ +45 dBm; 80 W +49 \/ +46; 100 W +50 \/ +47 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e78–79 dB min (standard); 67–70 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR28 UG cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e450–520 VA at PLin; 575–700 VA at PSat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e12.2 x 7.2 x 6.8 to 7.2 in (single, dual, quad band); 16.2 x 10 x 10.2 in (tri-band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e19.5 lb \/ 8.8 kg; tri-band 45 lb \/ 20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eKa-band gateway and hub terminals\u003c\/li\u003e\n\u003cli\u003eMilitary and commercial HTS uplinks\u003c\/li\u003e\n\u003cli\u003eMulti-orbit Ka-band networks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20G%20Ka-Band%2060%E2%80%93100W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%20G%2060%E2%80%93100W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110154607,"sku":"TRS-IBUCG-KA-60-100W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-g-gan-intelligent-buc-3.png?v=1793925080"},{"product_id":"terrasat-ibuc-g-ka-band-100-160w-buc","title":"Terrasat IBUC G Ka-Band 100–160W GaN Intelligent BUC","description":"\u003cp\u003eThe Terrasat IBUC G Ka-band 125 W and 160 W units deliver up to +52 dBm saturated and +49 dBm linear from an antenna-mounted GaN amplifier, with quad-band 100 W and 125 W versions. They give Ka-band gateways and high-throughput uplinks TWTA-class power with software-selectable sub-bands.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e125 W or 160 W PSat (+51 \/ +52 dBm); quad-band 100 W or 125 W\u003c\/li\u003e\n\u003cli\u003eSingle, dual, tri or quad-band versions; wide-conversion single-band option\u003c\/li\u003e\n\u003cli\u003eSoftware-selectable sub-bands on multiband models\u003c\/li\u003e\n\u003cli\u003eEthernet, SNMP and web M\u0026amp;C; optional Cyber Hardened Core\u003c\/li\u003e\n\u003cli\u003eWGS-compatible lower-gain version\u003c\/li\u003e\n\u003cli\u003e1+1 redundancy\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC G 100–160W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC G 100–160W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF frequency\u003c\/th\u003e\n\u003ctd\u003eSingle band: 29.0–30.0 or 30.0–31.0 GHz; dual band: 29.0–30.0 and 30.0–31.0 GHz; tri-band: 27.5–28.5, 28.25–29.25 and 29.0–30.0 GHz; quad-band: all four sub-bands, 27.5–31.0 GHz; single band also 29.5–30.0 GHz and 27.5–30.0 GHz wide conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF frequency\u003c\/th\u003e\n\u003ctd\u003e1.0–2.0 GHz or 950–1950 MHz; 1.25–3.75 GHz for wide conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003ePSat (typ) \/ PLin (min): 100 W +50 \/ +47 dBm; 125 W +51 \/ +48; 160 W +52 \/ +49 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplifier\u003c\/th\u003e\n\u003ctd\u003eGaN SSPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmall-signal gain\u003c\/th\u003e\n\u003ctd\u003e79 dB min (standard); 70–72 dB min (WGS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIF input\u003c\/th\u003e\n\u003ctd\u003eType N female 50 Ω; Type F 75 Ω optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output\u003c\/th\u003e\n\u003ctd\u003eWR28 UG cover with groove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz on the IFL; optional internal reference (30 ppb standard or 5 ppb high stability) with auto-detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e800–900 VA at PLin; 1,050–1,150 VA at PSat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (HTTP, Telnet, SNMPv2c) via RJ45; RS232\/485 and handheld terminal via MS-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e16.2 x 10 x 10.2 in (411 x 254 x 259 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e45 lb (20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eKa-band gateway and teleport uplinks\u003c\/li\u003e\n\u003cli\u003eHigh-throughput satellite (HTS) ground stations\u003c\/li\u003e\n\u003cli\u003eMilitary Ka-band hubs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eWhat is an IBUC?\u003c\/h4\u003e\u003cp\u003eIBUC is Terrasat's name for its Intelligent Block Upconverter: a BUC and solid-state power amplifier in one outdoor unit with built-in monitor and control. Every IBUC reports output power, temperature and alarms over Ethernet, SNMP and a web interface, and can be ordered with Terrasat's Cyber Hardened controller for encrypted management.\u003c\/p\u003e\u003ch4\u003eWhat is the WGS-compatible version?\u003c\/h4\u003e\u003cp\u003eTerrasat builds a lower-gain version of most IBUCs for Wideband Global SATCOM (WGS) and other terminals whose modems drive the IF at higher levels (up to 0 dBm). The standard version has higher gain to make up for loss in long IFL cable runs. Choose the gain version in the quote form, or ask us to confirm.\u003c\/p\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20G%20Ka-Band%20100%E2%80%93160W%20GaN%20Intelligent%20BUC\u0026amp;mpn=IBUC%20G%20100%E2%80%93160W\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110187375,"sku":"TRS-IBUCG-KA-100-160W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-g-gan-intelligent-buc.png?v=1793925080"},{"product_id":"terrasat-tx-1-1-ibuc-redundancy-system","title":"Terrasat Tx 1:1 IBUC Redundancy System","description":"\u003cp\u003eThe Terrasat Tx 1:1 redundancy system protects a transmit chain with two IBUCs, an L-band interface module and a waveguide switch, shipped assembled and pre-tested on a common plate. The interface module splits the L-band, 10 MHz and FSK signals to both IBUCs and switches to the standby unit on a fault, with Ethernet M\u0026amp;C and an optional Cyber Hardened controller.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTwo IBUCs, interface module and waveguide switch, shipped assembled and pre-tested\u003c\/li\u003e\n\u003cli\u003eL-band 950–2150 MHz (2750 MHz optional)\u003c\/li\u003e\n\u003cli\u003ePasses 10 MHz reference and FSK to both IBUCs\u003c\/li\u003e\n\u003cli\u003eEthernet, RS232\/485 and handheld M\u0026amp;C; Form-C summary alarms\u003c\/li\u003e\n\u003cli\u003eOptional Cyber Hardened M\u0026amp;C\u003c\/li\u003e\n\u003cli\u003eC, X, Ku and Ka-band systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eTx 1:1 IBUC Redundancy System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat Tx 1:1 IBUC Redundancy System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003e1:1 (one online, one standby IBUC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL-band frequency\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz (950–2750 MHz optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL-band insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlatness\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p in any 36 MHz; 2 dB p-p full band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eType N, Type F or TNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eFrom the modem via the IFL, 4 dB max loss; single or dual internal reference optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz pass-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch\u003c\/th\u003e\n\u003ctd\u003eWaveguide switch for C (WR137), X (WR112), Ku (WR75) or Ka-band (WR28)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003eSupplied by the IBUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (RJ45), RS232\/485 and handheld terminal; A and B Form-C summary alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003eAssembled and pre-tested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRedundant C, X, Ku and Ka-band uplinks\u003c\/li\u003e\n\u003cli\u003eTeleport and hub transmit chains\u003c\/li\u003e\n\u003cli\u003eUnmanned and remote earth stations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20Tx%201%3A1%20IBUC%20Redundancy%20System\u0026amp;mpn=Tx%201%3A1%20IBUC%20Redundancy%20System\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110220143,"sku":"TRS-TX11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-tx-1-1-ibuc-redundancy-system.png?v=1793925080"},{"product_id":"terrasat-tx-1-2-ibuc-redundancy-system","title":"Terrasat Tx 1:2 IBUC Redundancy System","description":"\u003cp\u003eThe Terrasat Tx 1:2 redundancy system protects two transmit chains with a single standby IBUC. Three IBUCs, the Tx 1:2 interface module and waveguide switches ship assembled and pre-tested on one plate, sized to the IBUC model and band, with Ethernet M\u0026amp;C and Form-C alarms for each unit.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree IBUCs (two online, one standby), interface module and waveguide switches\u003c\/li\u003e\n\u003cli\u003eL-band 950–2150 MHz\u003c\/li\u003e\n\u003cli\u003eOptional redundant internal 10 MHz reference with auto-detection of the external reference\u003c\/li\u003e\n\u003cli\u003eEthernet and RS232 M\u0026amp;C; Form-C relays for A, B and C\u003c\/li\u003e\n\u003cli\u003eShips assembled and pre-tested\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eTx 1:2 IBUC Redundancy System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat Tx 1:2 IBUC Redundancy System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003e1:2 (two online, one standby IBUC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL-band frequency\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL-band insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlatness\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p in any 36 MHz; 2 dB p-p full band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eType N or Type F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eRedundant internal reference optional; auto-detects the external reference; 2 dB max loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switches\u003c\/th\u003e\n\u003ctd\u003eWaveguide switch for C (WR137), X (WR112), Ku (WR75) or Ka-band (WR28)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface power\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (two RJ45), RS232 (PT02E-14-19S); Form-C relays A, B and C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003eAssembled and pre-tested; plate size depends on IBUC model and band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-carrier or dual-polarization uplinks\u003c\/li\u003e\n\u003cli\u003eTeleports protecting two transmit chains\u003c\/li\u003e\n\u003cli\u003eRemote earth stations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20Tx%201%3A2%20IBUC%20Redundancy%20System\u0026amp;mpn=Tx%201%3A2%20IBUC%20Redundancy%20System\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110252911,"sku":"TRS-TX12","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-tx-1-2-ibuc-redundancy-system.png?v=1793925080"},{"product_id":"terrasat-rx-1-1-lnb-redundancy-system","title":"Terrasat Rx 1:1 LNB Redundancy System","description":"\u003cp\u003eThe Terrasat Rx 1:1 redundancy system protects a receive chain with two LNBs, a waveguide switch and an L-band interface box that powers the LNBs and switches to the standby unit on a fault. It supplies 13–24 V LNB power with a 22 kHz tone, distributes the 10 MHz reference, and runs from AC or DC power.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInterface box, waveguide switch and LNB mounting for 1:1 receive protection\u003c\/li\u003e\n\u003cli\u003eL-band 950–2150 MHz (2750 MHz optional)\u003c\/li\u003e\n\u003cli\u003eLNB power at 13, 15, 18 or 24 V with 22 kHz tone\u003c\/li\u003e\n\u003cli\u003eInternal or redundant 10 MHz reference options\u003c\/li\u003e\n\u003cli\u003eEthernet, RS232\/485 and handheld M\u0026amp;C; optional Cyber Hardened version\u003c\/li\u003e\n\u003cli\u003eAC or 20–60 VDC power\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRx 1:1 LNB Redundancy System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat Rx 1:1 LNB Redundancy System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003e1:1 LNB redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL-band frequency\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz (950–2750 MHz optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL-band insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlatness\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p in any 36 MHz; 2 dB p-p full band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eType N female; Type F optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLNB power\u003c\/th\u003e\n\u003ctd\u003e13, 15, 18 or 24 V; 22 kHz tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eFrom the demodulator or an external source; single or redundant internal reference optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch\u003c\/th\u003e\n\u003ctd\u003eC-band 3.3–4.9 GHz or X-band 7.05–10.0 GHz (other bands on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC or 20–60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eEthernet (RJ45), RS232\/485 and handheld terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCyber security\u003c\/th\u003e\n\u003ctd\u003eOptional Cyber Hardened M\u0026amp;C: HTTPS, SSHv2, SNMPv3 (USM and VACM), two NTP servers, FIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface box\u003c\/th\u003e\n\u003ctd\u003e12.2 x 7.2 x 3.8 in, 10 lb (AC); 12.2 x 7.2 x 2.7 in, 7 lb (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRedundant C, X and Ku-band receive chains\u003c\/li\u003e\n\u003cli\u003eTeleport and hub downlinks\u003c\/li\u003e\n\u003cli\u003eUnmanned earth stations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20Rx%201%3A1%20LNB%20Redundancy%20System\u0026amp;mpn=Rx%201%3A1%20LNB%20Redundancy%20System\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110318447,"sku":"TRS-RX11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-rx-1-1-lnb-redundancy-system.png?v=1793925080"},{"product_id":"terrasat-ibuc-load-switch-system","title":"Terrasat IBUC Load Switch System","description":"\u003cp\u003eThe Terrasat Load Switch System adds a waveguide switch and dummy load to an IBUC installation, so the amplifier output can be switched into a load for testing or standby without breaking the waveguide run. Terrasat IBUCs detect the load switch automatically at start-up and control it through their own M\u0026amp;C.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWaveguide switch for C, X, Ku or Ka-band\u003c\/li\u003e\n\u003cli\u003eDetected automatically by Terrasat IBUCs at start-up\u003c\/li\u003e\n\u003cli\u003eControlled through the IBUC or the load switch interface module\u003c\/li\u003e\n\u003cli\u003eRS232\/485, handheld and Form-C summary alarm\u003c\/li\u003e\n\u003cli\u003ePowered by the IBUC; ships assembled and pre-tested\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC Load Switch System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUC Load Switch System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch\u003c\/th\u003e\n\u003ctd\u003eC-band 5.09–8.2 GHz (WR137); X-band 7.05–10.0 GHz (WR112); Ku-band 10–15 GHz (WR75); Ka-band 26.5–40 GHz (WR28)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.03 dB (C) to 0.15 dB (Ka) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e60–80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching time\u003c\/th\u003e\n\u003ctd\u003e80–100 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003eSupplied by the IBUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitor \u0026amp; control\u003c\/th\u003e\n\u003ctd\u003eVia the IBUC (Ethernet) or the interface module (RS232\/485, handheld, Form-C alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e100% condensing humidity; 10,000 ft (3,000 m) altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003eAssembled and pre-tested; plate size depends on IBUC model and band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIBUC testing and commissioning\u003c\/li\u003e\n\u003cli\u003eStandby operation of high-power IBUCs\u003c\/li\u003e\n\u003cli\u003eTeleport transmit chains\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%20Load%20Switch%20System\u0026amp;mpn=IBUC%20Load%20Switch%20System\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110351215,"sku":"TRS-LSW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-lsw-loadswitch-2024-03-05-1600x1067.jpg?v=1793925977"},{"product_id":"terrasat-cyber-hardened-ibuc-option","title":"Terrasat Cyber Hardened IBUC (Cyber Hardened Core M\u0026C)","description":"\u003cp\u003eTerrasat's Cyber Hardened Core is a controller board and firmware option for IBUCs in every band. It replaces clear-text HTTP, Telnet and SNMPv2c management with HTTPS, SSHv2 and SNMPv3, adds user accounts with lock-out, two NTP servers and cross-site-scripting protection, and is FIPS 140-2 compatible, for government and defense networks that require encrypted management of terminal equipment.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHTTPS web, SSHv2 command line and SNMPv3 (USM and VACM)\u003c\/li\u003e\n\u003cli\u003eFIPS 140-2 compatible; cross-site-scripting protection\u003c\/li\u003e\n\u003cli\u003eUser accounts with lock-out after 3 failed attempts\u003c\/li\u003e\n\u003cli\u003eTwo NTP servers for redundant time\u003c\/li\u003e\n\u003cli\u003eIPv4 and IPv6\u003c\/li\u003e\n\u003cli\u003eAvailable on C, X, Ku and Ka-band IBUCs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eCyber Hardened Core IBUC M\u0026amp;C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTerrasat Cyber Hardened Core IBUC M\u0026amp;C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable on\u003c\/th\u003e\n\u003ctd\u003eTerrasat IBUCs in C, X, Ku and Ka-band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeb\u003c\/th\u003e\n\u003ctd\u003eHTTPS (encrypted connections)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommand line\u003c\/th\u003e\n\u003ctd\u003eSSHv2 and serial port (115,200 bit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSNMP\u003c\/th\u003e\n\u003ctd\u003eSNMPv3 with USM and VACM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccounts\u003c\/th\u003e\n\u003ctd\u003e20 users by default; lock-out after 3 failed attempts; 15-minute unlock period\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime\u003c\/th\u003e\n\u003ctd\u003eTwo NTP servers for redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eFIPS 140-2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork\u003c\/th\u003e\n\u003ctd\u003eIPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard M\u0026amp;C (for comparison)\u003c\/th\u003e\n\u003ctd\u003eHTTP, Telnet and SNMPv2c without encryption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGovernment and defense satcom terminals\u003c\/li\u003e\n\u003cli\u003eNetworks with encrypted-management requirements\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure VSAT\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eDoes Digisat supply and support Terrasat IBUCs?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Terrasat Intelligent BUCs, redundancy systems and options with quote-based pricing for government, defense, teleport and enterprise buyers, and our engineers can help size the amplifier, choose the frequency plan and options, integrate the system and support it in the field.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20Cyber%20Hardened%20IBUC%20(Cyber%20Hardened%20Core%20M%26C)\u0026amp;mpn=Cyber%20Hardened%20Core%20IBUC%20M%26C\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110383983,"sku":"TRS-CHC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-cyber-hardened-core-ibuc-m-c.png?v=1793925079"},{"product_id":"terrasat-ibuc-2-dbs-band","title":"Terrasat IBUC 2 DBS-Band Intelligent BUC, 3 W to 25 W (Discontinued)","description":"\u003cp\u003e\u003cstrong\u003eDiscontinued: the Terrasat IBUC 2 DBS-Band is no longer manufactured.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTerrasat has discontinued the IBUC 2 DBS-Band Intelligent BUC, 3 W to 25 W. It is no longer built, but Digisat still supports installed units and can recommend and supply a current replacement.\u003c\/p\u003e\u003cp\u003eThe Terrasat Communications IBUC 2 DBS-Band provides low energy consumption for use with modems equipped with limited capacity BUC power supplies. DC power is supplied via IFL coax and extremely low phase noise better than IESS308\/309 requirements.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eIBUC 2 DBS-Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStatus\u003c\/th\u003e\n\u003ctd\u003eDiscontinued by Terrasat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent replacement\u003c\/th\u003e\n\u003ctd\u003eNo direct successor; ask Digisat for an equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eStill running a Terrasat IBUC 2 DBS-Band?\u003c\/h3\u003e\u003cp\u003eDigisat engineers troubleshoot, repair and maintain legacy satellite ground equipment, and plan migrations to current systems with minimal downtime. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Terrasat%20IBUC%202%20DBS-Band%20Intelligent%20BUC\u0026amp;mpn=IBUC%202%20DBS-Band\"\u003eRequest support or a replacement quote\u003c\/a\u003e.\u003c\/p\u003e","brand":"Terrasat","offers":[{"title":"Default Title","offer_id":67979110416751,"sku":"TRS-IBUC-2-DBS-BAND","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/terrasat-ibuc-2-dbs-band-intelligent-buc-3-w-to-25-w.jpg?v=1793925080"}],"url":"https:\/\/digisat.org\/collections\/terrasat.oembed","provider":"Digisat International","version":"1.0","type":"link"}