Teledyne Paradise Datacom PowerMAX Fault-Tolerant SSPA Systems

Teledyne Paradise Datacom's PowerMAX systems combine 4 to 16 SSPA modules with no active switching (all-passive power combining) and size the output for N+1 redundancy, so a module failure does not take the system off the air. Every active module and power supply is hot-swappable, the system is 100% field-maintainable, and it is controlled as if it were a single SSPA. Systems scale from 4 to 8 or 16 modules in the field. PowerMAX is covered by U.S. Patents 8,189,338 and 8,411,477.

Key features

  • 4 to 16 modules; field-scalable
  • All-passive power combining: no active switching
  • Output power sized for N+1 redundancy (soft-fail)
  • Hot-swap SSPA and power supply modules; 100% field maintainable
  • Monitor and control emulates a single SSPA; Ethernet (UDP, SNMP, web) and RS-485
  • Reflected power monitor; waveguide arc protection option

Teledyne Paradise Datacom PowerMAX Fault-Tolerant SSPA Systems products

Skip to results list

Active filters:

6 items
Column grid
Column grid

Filter

Active filters:

  • Teledyne Paradise Datacom Indoor GaAs PowerMAX SSPA System

    Teledyne Paradise Datacom Indoor GaAs PowerMAX SSPA System

    View specs & quote
  • Teledyne Paradise Datacom Indoor GaN PowerMAX SSPA System

    Teledyne Paradise Datacom Indoor GaN PowerMAX SSPA System

    View specs & quote
  • Teledyne Paradise Datacom Outdoor GaAs Compact PowerMAX SSPA System

    Teledyne Paradise Datacom Outdoor GaAs Compact PowerMAX SSPA System

    View specs & quote
  • Teledyne Paradise Datacom Outdoor GaAs High Power PowerMAX SSPA System

    Teledyne Paradise Datacom Outdoor GaAs High Power PowerMAX SSPA System

    View specs & quote
  • Teledyne Paradise Datacom Outdoor GaN Compact PowerMAX SSPA System

    Teledyne Paradise Datacom Outdoor GaN Compact PowerMAX SSPA System

    View specs & quote
  • Teledyne Paradise Datacom Outdoor GaN High Power PowerMAX SSPA System

    Teledyne Paradise Datacom Outdoor GaN High Power PowerMAX SSPA System

    View specs & quote

All 6 models

Part numberInstallationMaximum output
Indoor GaAs PowerMAXIndoor cabinet5.9 kW C-Band; 2.4 kW X-Band
Indoor GaN PowerMAXIndoor cabinet7.8 kW S-Band; see datasheet for C, X and Ku-Band
Outdoor GaN High Power PowerMAXOutdoor10 kW C and X-Band; 7.8 kW S-Band; 7.0 kW Ku-Band
Outdoor GaN Compact PowerMAXOutdoorExample: 2.5 kW C-Band with 16 x 250W modules
Outdoor GaAs Compact PowerMAXOutdoorExample: 1.6 kW C-Band with 8 x 250W modules
Outdoor GaAs High Power PowerMAXOutdoor5.9 kW C-Band

Specifications

Modules4 to 16
CombiningPassive, no active switching
RedundancyN+1 soft-fail

Applications

  • High-power teleport and DTH uplinks
  • Government and military gateways
  • Replacing klystron and TWT high-power amplifiers

Frequently asked questions

What happens when a PowerMAX module fails?

The system keeps transmitting: output is sized for N+1 so a single module failure leaves rated power available, and the failed module is hot-swapped without taking the uplink down.

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.