Teledyne Paradise Datacom's second-generation 3RU indoor GaN SSPAs reach 800W in L, S, C and X-Band and 600W in Ku-Band in a 5.25-inch chassis. Paradise's linearized GaN modules deliver linear output power with efficiency comparable to tube amplifiers, with higher output power, greater power-added efficiency and high reliability. The chassis has a color touchscreen, removable fan tray and M&C card, and a separate 1RU N+1 power supply.
Key features
- L, S, C and X-Band to 800W; Ku-Band to 600W (Psat)
- Front-panel color touchscreen with mimic display
- Remote M&C: RS-232/485, Ethernet with SNMP, UDP and web browser
- 20 dB RF gain adjustment; true RF output power measurement
- Built-in 1:1 redundancy and maintenance switch control
- Hot/cold standby modes to cut power consumption
- RF output sample port
- 1RU N+1 redundant power supply
- CE compliant
Teledyne Paradise Datacom 3RU Indoor GaN SSPAs products
All 26 models
| Part number | Band | Output power (Psat) |
|---|---|---|
| HPAL3100ARXXXXPG2 | L-Band | 50.0 dBm (100W) typical |
| HPAL3200ARXXXXPG2 | L-Band | 53.0 dBm (200W) typical |
| HPAL3300ARXXXXPG2 | L-Band | 54.8 dBm (300W) typical |
| HPAL3400ARXXXXPG2 | L-Band | 56.0 dBm (400W) typical |
| HPAL3500ARXXXXPG2 | L-Band | 57.0 dBm (500W) typical |
| HPAL3600ARXXXXPG2 | L-Band | 57.8 dBm (600W) typical |
| HPAL3800ARXXXXPG2 | L-Band | 59.0 dBm (800W) typical |
| HPAS3100ARXXXXPG2 | S-Band | 50.0 dBm (100W) typical |
| HPAS3200ARXXXXPG2 | S-Band | 53.0 dBm (200W) typical |
| HPAS3300ARXXXXPG2 | S-Band | 54.8 dBm (300W) typical |
| HPAS3400ARXXXXPG2 | S-Band | 56.0 dBm (400W) typical |
| HPAS3500ARXXXXPG2 | S-Band | 57.0 dBm (500W) typical |
| HPAS3600ARXXXXPG2 | S-Band | 57.8 dBm (600W) typical |
| HPAS3800ARXXXXPG2 | S-Band | 59.0 dBm (800W) typical |
| HPAC3200ARXXXXPG2 | C-Band | 53.0 dBm (200W) typical |
| HPAC3400ARXXXXPG2 | C-Band | 56.0 dBm (400W) typical |
| HPAC3800ARXXXXPG2 | C-Band | 59.0 dBm (800W) typical |
| HPAX3300ARXXXXPG2 | X-Band | 54.8 dBm (300W) typical |
| HPAX3400ARXXXXPG2 | X-Band | 56.0 dBm (400W) typical |
| HPAX3650ARXXXXPG2 | X-Band | 58.1 dBm (650W) typical |
| HPAX3800ARXXXXPG2 | X-Band | 59.0 dBm (800W) typical |
| HPAK3200ARXXXXPG2 | Ku-Band | 53.0 dBm (200W) typical |
| HPAK3250ARXXXXPG2 | Ku-Band | 54.0 dBm (250W) typical |
| HPAK3400ARXXXXPG2 | Ku-Band | 56.0 dBm (400W) typical |
| HPAK3500ARXXXXPG2 | Ku-Band | 57.0 dBm (500W) typical |
| HPAK3600ARXXXXPG2 | Ku-Band | 57.8 dBm (600W) typical |
Specifications
| Chassis | 3RU (5.25 in high), plus 1RU N+1 power supply |
|---|---|
| Operating temperature | 0 to +50 °C |
| Gain adjustment | 20 dB |
| Linear power | Linear power is per MIL-STD-188-164 (two tones 5 MHz apart, or ≤ -30 dBc spectral regrowth on OQPSK); Paradise rates GaN units for normal operation at PLinear, 3 dB below Psat. |
Applications
- Teleport and earth station uplinks
- Government and military SATCOM gateways
- Broadcast and DTH uplinks
- TT&C and command uplinks (L/S-Band)
Frequently asked questions
Should I size a GaN SSPA by Psat or PLinear?
By PLinear. Paradise rates GaN SSPAs for continuous operation at PLinear, 3 dB below Psat; running continuously at saturation can shorten amplifier life and is not covered by warranty. Digisat can size the amplifier from your link budget.
Need it installed, aligned or supported?
Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.