{"title":"Redundancy Switches","description":"\u003cp\u003eRedundancy switches transfer the RF path between online and standby units so receive and transmit chains stay up when a unit fails.\u003c\/p\u003e\u003cp\u003eDigisat supplies redundancy switches from Foxcom, International Datacasting, Norsat, Novelsat, Sencore and Terrasat with quote-based pricing for government, teleport and enterprise buyers, accepts purchase orders and GPC, and our engineers can help size, integrate, install and support the equipment. Browse 269 part numbers below, or ask us for a configuration that is not listed.\u003c\/p\u003e","products":[{"product_id":"norsat-rsbucka25","title":"Norsat RSBUCKA25 ATOM BUC 1:1 Redundant Switch System, 25W KA BUC","description":"\u003cp\u003eThe Norsat RSBUCKA25 is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 25W KA BUC; 10 MHz reference: None. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka50\"\u003e50W KA BUC (RSBUCKA50)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20\"\u003e20W Ku BUC (RSBUCKU20)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40\"\u003e40W Ku BUC (RSBUCKU40)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80\"\u003e80W Ku BUC (RSBUCKU80)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80g\"\u003e80W Ku GAN BUC (RSBUCKU80G)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25i\"\u003eSMA Port for External 10MHz Injection (RSBUCKA25I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka25r\"\u003eBuild in 10MHz (RSBUCKA25R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKA25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e25W KA BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e25W Ka BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e20.73 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 563.82 × 221.62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKA25%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKA25\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268085615,"sku":"NOR-RSBUCKA25","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucka25i","title":"Norsat RSBUCKA25I ATOM BUC 1:1 Redundant Switch System, 25W KA BUC, SMA Port for External 10MHz Injection","description":"\u003cp\u003eThe Norsat RSBUCKA25I is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 25W KA BUC; 10 MHz reference: SMA Port for External 10MHz Injection. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka50i\"\u003e50W KA BUC (RSBUCKA50I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20i\"\u003e20W Ku BUC (RSBUCKU20I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40i\"\u003e40W Ku BUC (RSBUCKU40I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80i\"\u003e80W Ku BUC (RSBUCKU80I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gi\"\u003e80W Ku GAN BUC (RSBUCKU80GI)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25\"\u003eNone (RSBUCKA25)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka25r\"\u003eBuild in 10MHz (RSBUCKA25R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKA25I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e25W KA BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e25W Ka BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e20.73 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 563.82 × 221.62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKA25I%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKA25I\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268183919,"sku":"NOR-RSBUCKA25I","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucka25r","title":"Norsat RSBUCKA25R ATOM BUC 1:1 Redundant Switch System, 25W KA BUC, Build in 10MHz","description":"\u003cp\u003eThe Norsat RSBUCKA25R is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 25W KA BUC; 10 MHz reference: Build in 10MHz. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka50r\"\u003e50W KA BUC (RSBUCKA50R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20r\"\u003e20W Ku BUC (RSBUCKU20R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40r\"\u003e40W Ku BUC (RSBUCKU40R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80r\"\u003e80W Ku BUC (RSBUCKU80R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gr\"\u003e80W Ku GAN BUC (RSBUCKU80GR)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25\"\u003eNone (RSBUCKA25)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka25i\"\u003eSMA Port for External 10MHz Injection (RSBUCKA25I)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKA25R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e25W KA BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e25W Ka BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e20.73 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 563.82 × 221.62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKA25R%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKA25R\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268314991,"sku":"NOR-RSBUCKA25R","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucka50","title":"Norsat RSBUCKA50 ATOM BUC 1:1 Redundant Switch System, 50W KA BUC","description":"\u003cp\u003eThe Norsat RSBUCKA50 is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 50W KA BUC; 10 MHz reference: None. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25\"\u003e25W KA BUC (RSBUCKA25)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20\"\u003e20W Ku BUC (RSBUCKU20)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40\"\u003e40W Ku BUC (RSBUCKU40)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80\"\u003e80W Ku BUC (RSBUCKU80)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80g\"\u003e80W Ku GAN BUC (RSBUCKU80G)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka50i\"\u003eSMA Port for External 10MHz Injection (RSBUCKA50I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50r\"\u003eBuild in 10MHz (RSBUCKA50R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKA50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e50W KA BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e50W Ka BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e24.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 573.22 × 221.62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKA50%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKA50\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268347759,"sku":"NOR-RSBUCKA50","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucka50i","title":"Norsat RSBUCKA50I ATOM BUC 1:1 Redundant Switch System, 50W KA BUC, SMA Port for External 10MHz Injection","description":"\u003cp\u003eThe Norsat RSBUCKA50I is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 50W KA BUC; 10 MHz reference: SMA Port for External 10MHz Injection. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25i\"\u003e25W KA BUC (RSBUCKA25I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20i\"\u003e20W Ku BUC (RSBUCKU20I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40i\"\u003e40W Ku BUC (RSBUCKU40I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80i\"\u003e80W Ku BUC (RSBUCKU80I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gi\"\u003e80W Ku GAN BUC (RSBUCKU80GI)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka50\"\u003eNone (RSBUCKA50)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50r\"\u003eBuild in 10MHz (RSBUCKA50R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKA50I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e50W KA BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e50W Ka BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e24.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 573.22 × 221.62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKA50I%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKA50I\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268380527,"sku":"NOR-RSBUCKA50I","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucka50r","title":"Norsat RSBUCKA50R ATOM BUC 1:1 Redundant Switch System, 50W KA BUC, Build in 10MHz","description":"\u003cp\u003eThe Norsat RSBUCKA50R is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 50W KA BUC; 10 MHz reference: Build in 10MHz. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25r\"\u003e25W KA BUC (RSBUCKA25R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20r\"\u003e20W Ku BUC (RSBUCKU20R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40r\"\u003e40W Ku BUC (RSBUCKU40R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80r\"\u003e80W Ku BUC (RSBUCKU80R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gr\"\u003e80W Ku GAN BUC (RSBUCKU80GR)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka50\"\u003eNone (RSBUCKA50)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50i\"\u003eSMA Port for External 10MHz Injection (RSBUCKA50I)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKA50R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e50W KA BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e50W Ka BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e24.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 573.22 × 221.62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKA50R%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKA50R\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268577135,"sku":"NOR-RSBUCKA50R","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku20","title":"Norsat RSBUCKU20 ATOM BUC 1:1 Redundant Switch System, 20W Ku BUC","description":"\u003cp\u003eThe Norsat RSBUCKU20 is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 20W Ku BUC; 10 MHz reference: None. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25\"\u003e25W KA BUC (RSBUCKA25)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50\"\u003e50W KA BUC (RSBUCKA50)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40\"\u003e40W Ku BUC (RSBUCKU40)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80\"\u003e80W Ku BUC (RSBUCKU80)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80g\"\u003e80W Ku GAN BUC (RSBUCKU80G)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku20i\"\u003eSMA Port for External 10MHz Injection (RSBUCKU20I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20r\"\u003eBuild in 10MHz (RSBUCKU20R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e20W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e20W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e20.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 565.22 × 257.84 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU20%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU20\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268675439,"sku":"NOR-RSBUCKU20","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku20i","title":"Norsat RSBUCKU20I ATOM BUC 1:1 Redundant Switch System, 20W Ku BUC, SMA Port for External 10MHz Injection","description":"\u003cp\u003eThe Norsat RSBUCKU20I is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 20W Ku BUC; 10 MHz reference: SMA Port for External 10MHz Injection. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25i\"\u003e25W KA BUC (RSBUCKA25I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50i\"\u003e50W KA BUC (RSBUCKA50I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40i\"\u003e40W Ku BUC (RSBUCKU40I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80i\"\u003e80W Ku BUC (RSBUCKU80I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gi\"\u003e80W Ku GAN BUC (RSBUCKU80GI)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku20\"\u003eNone (RSBUCKU20)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20r\"\u003eBuild in 10MHz (RSBUCKU20R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU20I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e20W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e20W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e20.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 565.22 × 257.84 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU20I%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU20I\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268806511,"sku":"NOR-RSBUCKU20I","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku20r","title":"Norsat RSBUCKU20R ATOM BUC 1:1 Redundant Switch System, 20W Ku BUC, Build in 10MHz","description":"\u003cp\u003eThe Norsat RSBUCKU20R is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 20W Ku BUC; 10 MHz reference: Build in 10MHz. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25r\"\u003e25W KA BUC (RSBUCKA25R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50r\"\u003e50W KA BUC (RSBUCKA50R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40r\"\u003e40W Ku BUC (RSBUCKU40R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80r\"\u003e80W Ku BUC (RSBUCKU80R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gr\"\u003e80W Ku GAN BUC (RSBUCKU80GR)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku20\"\u003eNone (RSBUCKU20)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20i\"\u003eSMA Port for External 10MHz Injection (RSBUCKU20I)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e20W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e20W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e20.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 565.22 × 257.84 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU20R%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU20R\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268839279,"sku":"NOR-RSBUCKU20R","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku40","title":"Norsat RSBUCKU40 ATOM BUC 1:1 Redundant Switch System, 40W Ku BUC","description":"\u003cp\u003eThe Norsat RSBUCKU40 is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 40W Ku BUC; 10 MHz reference: None. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25\"\u003e25W KA BUC (RSBUCKA25)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50\"\u003e50W KA BUC (RSBUCKA50)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20\"\u003e20W Ku BUC (RSBUCKU20)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80\"\u003e80W Ku BUC (RSBUCKU80)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80g\"\u003e80W Ku GAN BUC (RSBUCKU80G)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku40i\"\u003eSMA Port for External 10MHz Injection (RSBUCKU40I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40r\"\u003eBuild in 10MHz (RSBUCKU40R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e40W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e40W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e22.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 563.82 × 251.46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU40%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU40\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268872047,"sku":"NOR-RSBUCKU40","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku40i","title":"Norsat RSBUCKU40I ATOM BUC 1:1 Redundant Switch System, 40W Ku BUC, SMA Port for External 10MHz Injection","description":"\u003cp\u003eThe Norsat RSBUCKU40I is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 40W Ku BUC; 10 MHz reference: SMA Port for External 10MHz Injection. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25i\"\u003e25W KA BUC (RSBUCKA25I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50i\"\u003e50W KA BUC (RSBUCKA50I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20i\"\u003e20W Ku BUC (RSBUCKU20I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80i\"\u003e80W Ku BUC (RSBUCKU80I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gi\"\u003e80W Ku GAN BUC (RSBUCKU80GI)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku40\"\u003eNone (RSBUCKU40)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40r\"\u003eBuild in 10MHz (RSBUCKU40R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU40I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e40W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e40W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e22.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 563.82 × 251.46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU40I%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU40I\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964268970351,"sku":"NOR-RSBUCKU40I","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku40r","title":"Norsat RSBUCKU40R ATOM BUC 1:1 Redundant Switch System, 40W Ku BUC, Build in 10MHz","description":"\u003cp\u003eThe Norsat RSBUCKU40R is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 40W Ku BUC; 10 MHz reference: Build in 10MHz. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25r\"\u003e25W KA BUC (RSBUCKA25R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50r\"\u003e50W KA BUC (RSBUCKA50R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20r\"\u003e20W Ku BUC (RSBUCKU20R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80r\"\u003e80W Ku BUC (RSBUCKU80R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gr\"\u003e80W Ku GAN BUC (RSBUCKU80GR)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku40\"\u003eNone (RSBUCKU40)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40i\"\u003eSMA Port for External 10MHz Injection (RSBUCKU40I)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU40R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e40W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e40W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e22.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 563.82 × 251.46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU40R%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU40R\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964269003119,"sku":"NOR-RSBUCKU40R","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku80","title":"Norsat RSBUCKU80 ATOM BUC 1:1 Redundant Switch System, 80W Ku BUC","description":"\u003cp\u003eThe Norsat RSBUCKU80 is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 80W Ku BUC; 10 MHz reference: None. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25\"\u003e25W KA BUC (RSBUCKA25)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50\"\u003e50W KA BUC (RSBUCKA50)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20\"\u003e20W Ku BUC (RSBUCKU20)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40\"\u003e40W Ku BUC (RSBUCKU40)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80g\"\u003e80W Ku GAN BUC (RSBUCKU80G)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku80i\"\u003eSMA Port for External 10MHz Injection (RSBUCKU80I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80r\"\u003eBuild in 10MHz (RSBUCKU80R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e80W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e80W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e33.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 573.22 × 245.41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU80%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU80\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964269101423,"sku":"NOR-RSBUCKU80","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku80i","title":"Norsat RSBUCKU80I ATOM BUC 1:1 Redundant Switch System, 80W Ku BUC, SMA Port for External 10MHz Injection","description":"\u003cp\u003eThe Norsat RSBUCKU80I is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 80W Ku BUC; 10 MHz reference: SMA Port for External 10MHz Injection. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25i\"\u003e25W KA BUC (RSBUCKA25I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50i\"\u003e50W KA BUC (RSBUCKA50I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20i\"\u003e20W Ku BUC (RSBUCKU20I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40i\"\u003e40W Ku BUC (RSBUCKU40I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gi\"\u003e80W Ku GAN BUC (RSBUCKU80GI)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku80\"\u003eNone (RSBUCKU80)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80r\"\u003eBuild in 10MHz (RSBUCKU80R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU80I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e80W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e80W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e33.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 573.22 × 245.41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU80I%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU80I\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964269265263,"sku":"NOR-RSBUCKU80I","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku80r","title":"Norsat RSBUCKU80R ATOM BUC 1:1 Redundant Switch System, 80W Ku BUC, Build in 10MHz","description":"\u003cp\u003eThe Norsat RSBUCKU80R is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 80W Ku BUC; 10 MHz reference: Build in 10MHz. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25r\"\u003e25W KA BUC (RSBUCKA25R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50r\"\u003e50W KA BUC (RSBUCKA50R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20r\"\u003e20W Ku BUC (RSBUCKU20R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40r\"\u003e40W Ku BUC (RSBUCKU40R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gr\"\u003e80W Ku GAN BUC (RSBUCKU80GR)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku80\"\u003eNone (RSBUCKU80)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80i\"\u003eSMA Port for External 10MHz Injection (RSBUCKU80I)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU80R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e80W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e80W Ku BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e33.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 573.22 × 245.41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU80R%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU80R\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964269429103,"sku":"NOR-RSBUCKU80R","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku80g","title":"Norsat RSBUCKU80G ATOM BUC 1:1 Redundant Switch System, 80W Ku GAN BUC","description":"\u003cp\u003eThe Norsat RSBUCKU80G is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 80W Ku GAN BUC; 10 MHz reference: None. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25\"\u003e25W KA BUC (RSBUCKA25)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50\"\u003e50W KA BUC (RSBUCKA50)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20\"\u003e20W Ku BUC (RSBUCKU20)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40\"\u003e40W Ku BUC (RSBUCKU40)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80\"\u003e80W Ku BUC (RSBUCKU80)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku80gi\"\u003eSMA Port for External 10MHz Injection (RSBUCKU80GI)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gr\"\u003eBuild in 10MHz (RSBUCKU80GR)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU80G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e80W Ku GAN BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e80W Ku GAN BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e25.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 573.22 × 245.41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU80G%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU80G\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964269625711,"sku":"NOR-RSBUCKU80G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku80gi","title":"Norsat RSBUCKU80GI ATOM BUC 1:1 Redundant Switch System, 80W Ku GAN BUC, SMA Port for External 10MHz Injection","description":"\u003cp\u003eThe Norsat RSBUCKU80GI is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 80W Ku GAN BUC; 10 MHz reference: SMA Port for External 10MHz Injection. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25i\"\u003e25W KA BUC (RSBUCKA25I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50i\"\u003e50W KA BUC (RSBUCKA50I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20i\"\u003e20W Ku BUC (RSBUCKU20I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40i\"\u003e40W Ku BUC (RSBUCKU40I)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80i\"\u003e80W Ku BUC (RSBUCKU80I)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku80g\"\u003eNone (RSBUCKU80G)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gr\"\u003eBuild in 10MHz (RSBUCKU80GR)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU80GI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e80W Ku GAN BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eSMA Port for External 10MHz Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e80W Ku GAN BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e25.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 573.22 × 245.41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU80GI%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU80GI\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964269691247,"sku":"NOR-RSBUCKU80GI","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucku80gr","title":"Norsat RSBUCKU80GR ATOM BUC 1:1 Redundant Switch System, 80W Ku GAN BUC, Build in 10MHz","description":"\u003cp\u003eThe Norsat RSBUCKU80GR is an ATOM BUC 1:1 Redundant Switch System from Norsat's ATOM BUC Redundant Switch range. It monitors the active ATOM BUC and switches automatically to the standby unit on a fault, keeping the uplink on air.\u003c\/p\u003e\u003cp\u003eThis configuration: BUC model: 80W Ku GAN BUC; 10 MHz reference: Build in 10MHz. Key specs: Insertion loss: 6 dB max; Redundancy: 1:1; Power: 100–240 VAC (50–60 Hz).\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The ATOM BUC Redundant Switch Series comes in 18 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC model:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucka25r\"\u003e25W KA BUC (RSBUCKA25R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucka50r\"\u003e50W KA BUC (RSBUCKA50R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku20r\"\u003e20W Ku BUC (RSBUCKU20R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku40r\"\u003e40W Ku BUC (RSBUCKU40R)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80r\"\u003e80W Ku BUC (RSBUCKU80R)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 MHz reference:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucku80g\"\u003eNone (RSBUCKU80G)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucku80gi\"\u003eSMA Port for External 10MHz Injection (RSBUCKU80GI)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-atom-buc-1-1-redundant-switch-system\"\u003eCompare all 18 Norsat ATOM BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCKU80GR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat ATOM BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e10 MHz Source Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC model\u003c\/th\u003e\n\u003ctd\u003e80W Ku GAN BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10 MHz reference\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOptional add-ons\u003c\/th\u003e\n\u003ctd\u003eBuild in 10MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eBUC Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e6 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC (50–60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003e80W Ku GAN BUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eWR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching\u003c\/th\u003e\n\u003ctd\u003eAtomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eSerial, SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;100% (ODU); \u0026lt;95% non-condensing (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60?C (ODU); -5 to +45?C (IDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (including BUCs)\u003c\/th\u003e\n\u003ctd\u003e25.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e673.1 × 573.22 × 245.41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCKU80GR%20ATOM%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCKU80GR\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964269756783,"sku":"NOR-RSBUCKU80GR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-atom-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucwmku","title":"Norsat RSBUCWMKU BUC 1:1 Redundant Switch System, mini Ku-Band","description":"\u003cp\u003eThe Norsat RSBUCWMKU is a BUC 1:1 Redundant Switch System from Norsat's BUC Redundant Switch range. It switches automatically to the standby BUC on a fault (1 s maximum switchover), with manual override from a remote PC.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: mini Ku-Band. Key specs: Switchover time: 1s (max.); Insertion loss: 5 dB max; Power: 85 – 265 VAC.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The BUC Redundant Switch Series comes in 3 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucwku\"\u003eKu-Band (RSBUCWKU)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucwc\"\u003eC-Band (RSBUCWC)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-buc-1-1-redundant-switch-system-c-ku\"\u003eCompare all 3 Norsat BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCWMKU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e16–80W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e1s (max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput power\u003c\/th\u003e\n\u003ctd\u003e+10 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e2 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e18 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e85 – 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic mode\u003c\/th\u003e\n\u003ctd\u003eAutomatic Switching upon fault status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eF-Connector or N-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u0026amp;C interface\u003c\/th\u003e\n\u003ctd\u003eRS232, RS485 or Ethernet\/SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManual mode\u003c\/th\u003e\n\u003ctd\u003eManual Override via remote PC Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, storage\u003c\/th\u003e\n\u003ctd\u003e-50 to 85℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded accessory\u003c\/th\u003e\n\u003ctd\u003eCables for connecting the BUCs and the RCU, an MS connector plug for power, and an MS connector for the M\u0026amp;C connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical dimensions\u003c\/th\u003e\n\u003ctd\u003e380 x 315 x 182.4 mm (mini Ku-Band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e1.56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e190 × 137 × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eRepublic of Korea\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCWMKU%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCWMKU\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964269953391,"sku":"NOR-RSBUCWMKU","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucwku","title":"Norsat RSBUCWKU BUC 1:1 Redundant Switch System, Ku-Band","description":"\u003cp\u003eThe Norsat RSBUCWKU is a BUC 1:1 Redundant Switch System from Norsat's BUC Redundant Switch range. It switches automatically to the standby BUC on a fault (1 s maximum switchover), with manual override from a remote PC.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: Ku-Band. Key specs: Switchover time: 1s (max.); Insertion loss: 5 dB max; Power: 110VAC \u0026amp; 220VAC.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The BUC Redundant Switch Series comes in 3 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucwmku\"\u003emini Ku-Band (RSBUCWMKU)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucwc\"\u003eC-Band (RSBUCWC)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-buc-1-1-redundant-switch-system-c-ku\"\u003eCompare all 3 Norsat BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCWKU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e16–80W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e1s (max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput power\u003c\/th\u003e\n\u003ctd\u003e+10 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e2 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e18 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.1 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF waveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.1 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF waveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e60 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e110VAC \u0026amp; 220VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic mode\u003c\/th\u003e\n\u003ctd\u003eAutomatic Switching upon fault status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eF-Connector or N-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u0026amp;C interface\u003c\/th\u003e\n\u003ctd\u003eRS232, RS485 or Ethernet\/SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManual mode\u003c\/th\u003e\n\u003ctd\u003eManual Override via remote PC Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, storage\u003c\/th\u003e\n\u003ctd\u003e-40 to 85℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded accessory\u003c\/th\u003e\n\u003ctd\u003eCables for connecting the BUCs and the RCU, an MS connector plug for power, and an MS connector for the M\u0026amp;C connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical dimensions\u003c\/th\u003e\n\u003ctd\u003e380 X 315 X 198 mm (16\/20\/25W RCS); 430 X 390 X 202.6 mm (40W RCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical weight\u003c\/th\u003e\n\u003ctd\u003e9 kg (16\/20\/25W RCS); 15 kg (40W RCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e1.56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e190 × 137 × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eRepublic of Korea\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCWKU%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCWKU\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964270149999,"sku":"NOR-RSBUCWKU","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucwc","title":"Norsat RSBUCWC BUC 1:1 Redundant Switch System, C-Band","description":"\u003cp\u003eThe Norsat RSBUCWC is a BUC 1:1 Redundant Switch System from Norsat's BUC Redundant Switch range. It switches automatically to the standby BUC on a fault (1 s maximum switchover), with manual override from a remote PC.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: C-Band. Key specs: Switchover time: 1s (max.); Insertion loss: 5 dB max; Power: 110VAC \u0026amp; 220VAC.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The BUC Redundant Switch Series comes in 3 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucwmku\"\u003emini Ku-Band (RSBUCWMKU)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucwku\"\u003eKu-Band (RSBUCWKU)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-buc-1-1-redundant-switch-system-c-ku\"\u003eCompare all 3 Norsat BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCWC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat BUC Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e20–100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e1s (max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput power\u003c\/th\u003e\n\u003ctd\u003e+10 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e2 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e18 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.1 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise 0.1kHz offset (max.)\u003c\/th\u003e\n\u003ctd\u003e-65 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF waveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.1 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF waveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e60 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e110VAC \u0026amp; 220VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic mode\u003c\/th\u003e\n\u003ctd\u003eAutomatic Switching upon fault status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eF-Connector or N-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u0026amp;C interface\u003c\/th\u003e\n\u003ctd\u003eRS232, RS485 or Ethernet\/SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManual mode\u003c\/th\u003e\n\u003ctd\u003eManual Override via remote PC Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, storage\u003c\/th\u003e\n\u003ctd\u003e-40 to 85℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded accessory\u003c\/th\u003e\n\u003ctd\u003eCables for connecting the BUCs and the RCU, an MS connector plug for power, and an MS connector for the M\u0026amp;C connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical dimensions\u003c\/th\u003e\n\u003ctd\u003e520 x 485 x 280.18 mm (C-Band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical weight\u003c\/th\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e1.56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e190 × 137 × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eRepublic of Korea\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCWC%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCWC\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964270215535,"sku":"NOR-RSBUCWC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-buc-1-1-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rsbucmctb11","title":"Norsat RSBUCMCTB11 MEDIAN BUC 1:1 Redundant Switch System, C-Band, 266.7 × 152.4 mm (5–80W GaAs, 100W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMCTB11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: C-Band; BUC enclosure: 266.7 × 152.4 mm (5–80W GaAs, 100W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmctd11\"\u003e411 × 254 mm (100–200W GaAs, 200W GaN) (RSBUCMCTD11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmcgf11\"\u003e610 × 254 mm (400W GaN) (RSBUCMCGF11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMCTB11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e266.7 × 152.4 mm (5–80W GaAs, 100W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e15–80W GaAs; 5–20W GaAs; 100W GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e266.7 x 152.4 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e5.09–8.20 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.03 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.05 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR137\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e100 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMCTB11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMCTB11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964270281071,"sku":"NOR-RSBUCMCTB11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmctd11","title":"Norsat RSBUCMCTD11 MEDIAN BUC 1:1 Redundant Switch System, C-Band, 411 × 254 mm (100–200W GaAs, 200W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMCTD11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: C-Band; BUC enclosure: 411 × 254 mm (100–200W GaAs, 200W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmctb11\"\u003e266.7 × 152.4 mm (5–80W GaAs, 100W GaN) (RSBUCMCTB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmcgf11\"\u003e610 × 254 mm (400W GaN) (RSBUCMCGF11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMCTD11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e411 × 254 mm (100–200W GaAs, 200W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e100–200W GaAs; 200W GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e411 x 254 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e5.09–8.20 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.03 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.05 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR137\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e100 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMCTD11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMCTD11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964270313839,"sku":"NOR-RSBUCMCTD11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmcgf11","title":"Norsat RSBUCMCGF11 MEDIAN BUC 1:1 Redundant Switch System, C-Band, 610 × 254 mm (400W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMCGF11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: C-Band; BUC enclosure: 610 × 254 mm (400W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmxgf11\"\u003eX-Band (RSBUCMXGF11)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmctb11\"\u003e266.7 × 152.4 mm (5–80W GaAs, 100W GaN) (RSBUCMCTB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmctd11\"\u003e411 × 254 mm (100–200W GaAs, 200W GaN) (RSBUCMCTD11)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMCGF11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e610 × 254 mm (400W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e400W GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e610 x 254 x 188 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e5.09–8.20 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.03 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.05 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR137\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e100 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMCGF11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMCGF11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964270772591,"sku":"NOR-RSBUCMCGF11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmxtb11","title":"Norsat RSBUCMXTB11 MEDIAN BUC 1:1 Redundant Switch System, X-Band, 266.7 × 152.4 mm (5–60W GaAs, 100W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMXTB11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: X-Band; BUC enclosure: 266.7 × 152.4 mm (5–60W GaAs, 100W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmxac11\"\u003e310 × 183 mm (80W GaAs) (RSBUCMXAC11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmxtd11\"\u003e411 × 254 mm (100–175W GaAs, 200W GaN) (RSBUCMXTD11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmxgf11\"\u003e610 × 254 mm (400W GaN) (RSBUCMXGF11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMXTB11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e266.7 × 152.4 mm (5–60W GaAs, 100W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e5–60W GaAs; 100W GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e266.7 x 152.4 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e7.05–10.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.05 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e80 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e100 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMXTB11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMXTB11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964271231343,"sku":"NOR-RSBUCMXTB11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmxac11","title":"Norsat RSBUCMXAC11 MEDIAN BUC 1:1 Redundant Switch System, X-Band, 310 × 183 mm (80W GaAs)","description":"\u003cp\u003eThe Norsat RSBUCMXAC11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: X-Band; BUC enclosure: 310 × 183 mm (80W GaAs). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmxtb11\"\u003e266.7 × 152.4 mm (5–60W GaAs, 100W GaN) (RSBUCMXTB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmxtd11\"\u003e411 × 254 mm (100–175W GaAs, 200W GaN) (RSBUCMXTD11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmxgf11\"\u003e610 × 254 mm (400W GaN) (RSBUCMXGF11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMXAC11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e310 × 183 mm (80W GaAs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e80W GaAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e310 x 183 x 173 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e7.05–10.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.05 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e80 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e100 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMXAC11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMXAC11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964271264111,"sku":"NOR-RSBUCMXAC11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmxtd11","title":"Norsat RSBUCMXTD11 MEDIAN BUC 1:1 Redundant Switch System, X-Band, 411 × 254 mm (100–175W GaAs, 200W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMXTD11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: X-Band; BUC enclosure: 411 × 254 mm (100–175W GaAs, 200W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmxtb11\"\u003e266.7 × 152.4 mm (5–60W GaAs, 100W GaN) (RSBUCMXTB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmxac11\"\u003e310 × 183 mm (80W GaAs) (RSBUCMXAC11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmxgf11\"\u003e610 × 254 mm (400W GaN) (RSBUCMXGF11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMXTD11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e411 × 254 mm (100–175W GaAs, 200W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e100–175W GaAs; 200W GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e411 x 254 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e7.05–10.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.05 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e80 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e100 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMXTD11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMXTD11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964271362415,"sku":"NOR-RSBUCMXTD11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmxgf11","title":"Norsat RSBUCMXGF11 MEDIAN BUC 1:1 Redundant Switch System, X-Band, 610 × 254 mm (400W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMXGF11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: X-Band; BUC enclosure: 610 × 254 mm (400W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmcgf11\"\u003eC-Band (RSBUCMCGF11)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmxtb11\"\u003e266.7 × 152.4 mm (5–60W GaAs, 100W GaN) (RSBUCMXTB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmxac11\"\u003e310 × 183 mm (80W GaAs) (RSBUCMXAC11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmxtd11\"\u003e411 × 254 mm (100–175W GaAs, 200W GaN) (RSBUCMXTD11)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMXGF11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e610 × 254 mm (400W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e400W GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e610 x 254 x 188 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e7.05–10.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.05 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e80 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e100 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMXGF11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMXGF11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964271395183,"sku":"NOR-RSBUCMXGF11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmkuta11","title":"Norsat RSBUCMKUTA11 MEDIAN BUC 1:1 Redundant Switch System, Ku-Band, 177.8 × 127 mm (8–16W GaAs, 25–40W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMKUTA11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: Ku-Band; BUC enclosure: 177.8 × 127 mm (8–16W GaAs, 25–40W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmkutb11\"\u003e266.7 × 152.4 mm (4–50W GaAs, 50–80W GaN) (RSBUCMKUTB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkutc11\"\u003e310 × 183 mm (60W GaAs, 100W GaN) (RSBUCMKUTC11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkuad11\"\u003e411 × 254 mm (80–100W GaAs) (RSBUCMKUAD11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkute11\"\u003e584 × 254 mm (100–125W GaAs, 150–200W GaN) (RSBUCMKUTE11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkugh11\"\u003e737 × 381 mm (300–400W GaN) (RSBUCMKUGH11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMKUTA11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e177.8 × 127 mm (8–16W GaAs, 25–40W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e8W-16W GaAs; 25–40W GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e177.8 x 127 x 101.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e10.00–15.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.05 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e75 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e80 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMKUTA11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMKUTA11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964271526255,"sku":"NOR-RSBUCMKUTA11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmkutb11","title":"Norsat RSBUCMKUTB11 MEDIAN BUC 1:1 Redundant Switch System, Ku-Band, 266.7 × 152.4 mm (4–50W GaAs, 50–80W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMKUTB11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: Ku-Band; BUC enclosure: 266.7 × 152.4 mm (4–50W GaAs, 50–80W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmkuta11\"\u003e177.8 × 127 mm (8–16W GaAs, 25–40W GaN) (RSBUCMKUTA11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkutc11\"\u003e310 × 183 mm (60W GaAs, 100W GaN) (RSBUCMKUTC11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkuad11\"\u003e411 × 254 mm (80–100W GaAs) (RSBUCMKUAD11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkute11\"\u003e584 × 254 mm (100–125W GaAs, 150–200W GaN) (RSBUCMKUTE11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkugh11\"\u003e737 × 381 mm (300–400W GaN) (RSBUCMKUGH11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMKUTB11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e266.7 × 152.4 mm (4–50W GaAs, 50–80W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e4–50W GaAs; 4–16W GaAs; 50\/60\/80W GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e266.7 x 152.4 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e10.00–15.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.05 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e75 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e80 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMKUTB11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMKUTB11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964271559023,"sku":"NOR-RSBUCMKUTB11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmkutc11","title":"Norsat RSBUCMKUTC11 MEDIAN BUC 1:1 Redundant Switch System, Ku-Band, 310 × 183 mm (60W GaAs, 100W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMKUTC11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: Ku-Band; BUC enclosure: 310 × 183 mm (60W GaAs, 100W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmkuta11\"\u003e177.8 × 127 mm (8–16W GaAs, 25–40W GaN) (RSBUCMKUTA11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkutb11\"\u003e266.7 × 152.4 mm (4–50W GaAs, 50–80W GaN) (RSBUCMKUTB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkuad11\"\u003e411 × 254 mm (80–100W GaAs) (RSBUCMKUAD11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkute11\"\u003e584 × 254 mm (100–125W GaAs, 150–200W GaN) (RSBUCMKUTE11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkugh11\"\u003e737 × 381 mm (300–400W GaN) (RSBUCMKUGH11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMKUTC11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e310 × 183 mm (60W GaAs, 100W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e60W GaAs; 100W GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e310 x 183 x 173 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e10.00–15.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.05 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e75 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e80 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMKUTC11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMKUTC11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964279849327,"sku":"NOR-RSBUCMKUTC11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmkuad11","title":"Norsat RSBUCMKUAD11 MEDIAN BUC 1:1 Redundant Switch System, Ku-Band, 411 × 254 mm (80–100W GaAs)","description":"\u003cp\u003eThe Norsat RSBUCMKUAD11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: Ku-Band; BUC enclosure: 411 × 254 mm (80–100W GaAs). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmkuta11\"\u003e177.8 × 127 mm (8–16W GaAs, 25–40W GaN) (RSBUCMKUTA11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkutb11\"\u003e266.7 × 152.4 mm (4–50W GaAs, 50–80W GaN) (RSBUCMKUTB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkutc11\"\u003e310 × 183 mm (60W GaAs, 100W GaN) (RSBUCMKUTC11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkute11\"\u003e584 × 254 mm (100–125W GaAs, 150–200W GaN) (RSBUCMKUTE11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkugh11\"\u003e737 × 381 mm (300–400W GaN) (RSBUCMKUGH11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMKUAD11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e411 × 254 mm (80–100W GaAs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e80W GaAs; 100W GaAs A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e411 x 254 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e10.00–15.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.05 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e75 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e80 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMKUAD11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMKUAD11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964279882095,"sku":"NOR-RSBUCMKUAD11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmkute11","title":"Norsat RSBUCMKUTE11 MEDIAN BUC 1:1 Redundant Switch System, Ku-Band, 584 × 254 mm (100–125W GaAs, 150–200W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMKUTE11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: Ku-Band; BUC enclosure: 584 × 254 mm (100–125W GaAs, 150–200W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmkuta11\"\u003e177.8 × 127 mm (8–16W GaAs, 25–40W GaN) (RSBUCMKUTA11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkutb11\"\u003e266.7 × 152.4 mm (4–50W GaAs, 50–80W GaN) (RSBUCMKUTB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkutc11\"\u003e310 × 183 mm (60W GaAs, 100W GaN) (RSBUCMKUTC11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkuad11\"\u003e411 × 254 mm (80–100W GaAs) (RSBUCMKUAD11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkugh11\"\u003e737 × 381 mm (300–400W GaN) (RSBUCMKUGH11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMKUTE11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e584 × 254 mm (100–125W GaAs, 150–200W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e100W GaAs S\u0026amp;E; 125W GaAs Low; 150\/200 GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e584 x 254 x 188 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e10.00–15.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.05 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e75 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e80 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMKUTE11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMKUTE11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964279914863,"sku":"NOR-RSBUCMKUTE11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmkugh11","title":"Norsat RSBUCMKUGH11 MEDIAN BUC 1:1 Redundant Switch System, Ku-Band, 737 × 381 mm (300–400W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMKUGH11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: Ku-Band; BUC enclosure: 737 × 381 mm (300–400W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmkuta11\"\u003e177.8 × 127 mm (8–16W GaAs, 25–40W GaN) (RSBUCMKUTA11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkutb11\"\u003e266.7 × 152.4 mm (4–50W GaAs, 50–80W GaN) (RSBUCMKUTB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkutc11\"\u003e310 × 183 mm (60W GaAs, 100W GaN) (RSBUCMKUTC11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkuad11\"\u003e411 × 254 mm (80–100W GaAs) (RSBUCMKUAD11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkute11\"\u003e584 × 254 mm (100–125W GaAs, 150–200W GaN) (RSBUCMKUTE11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMKUGH11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e737 × 381 mm (300–400W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e300\/400W GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e737 x 381 x 257 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e10.00–15.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.05 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e75 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e80 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMKUGH11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMKUGH11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964279947631,"sku":"NOR-RSBUCMKUGH11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmkaga11","title":"Norsat RSBUCMKAGA11 MEDIAN BUC 1:1 Redundant Switch System, Ka-Band, 266.7 × 152.4 mm (5–50W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMKAGA11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: Ka-Band; BUC enclosure: 266.7 × 152.4 mm (5–50W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmkagb11\"\u003e310 × 183 mm (80–100W GaN) (RSBUCMKAGB11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkagd11\"\u003e411 × 254 mm (125–160W GaN) (RSBUCMKAGD11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMKAGA11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e266.7 × 152.4 mm (5–50W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e5–50W GaN, for all multibands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e266.7 x 152.4 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e26.50–40.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.15 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e60 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e80 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMKAGA11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMKAGA11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964279980399,"sku":"NOR-RSBUCMKAGA11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmkagb11","title":"Norsat RSBUCMKAGB11 MEDIAN BUC 1:1 Redundant Switch System, Ka-Band, 310 × 183 mm (80–100W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMKAGB11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: Ka-Band; BUC enclosure: 310 × 183 mm (80–100W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmkaga11\"\u003e266.7 × 152.4 mm (5–50W GaN) (RSBUCMKAGA11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkagd11\"\u003e411 × 254 mm (125–160W GaN) (RSBUCMKAGD11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMKAGB11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e310 × 183 mm (80–100W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e80\/100W GaN, including multibands (Includes Quad-band 60W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e310 x 183 x 173 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e26.50–40.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.15 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e60 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e80 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMKAGB11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMKAGB11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280045935,"sku":"NOR-RSBUCMKAGB11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rsbucmkagd11","title":"Norsat RSBUCMKAGD11 MEDIAN BUC 1:1 Redundant Switch System, Ka-Band, 411 × 254 mm (125–160W GaN)","description":"\u003cp\u003eThe Norsat RSBUCMKAGD11 is a MEDIAN BUC 1:1 Redundant Switch System from Norsat's MEDIAN Redundant Switch range. It pairs two MEDIAN BUCs with a waveguide switch and controller, powered by the BUCs themselves, for automatic or manual 1:1 transmit redundancy.\u003c\/p\u003e\u003cp\u003eThis configuration: Band: Ka-Band; BUC enclosure: 411 × 254 mm (125–160W GaN). Key specs: Insertion loss: 5 dB max (includes split); Frequency range: 950–2150 MHz.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The MEDIAN Redundant Switch Series comes in 16 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eBUC enclosure:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rsbucmkaga11\"\u003e266.7 × 152.4 mm (5–50W GaN) (RSBUCMKAGA11)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rsbucmkagb11\"\u003e310 × 183 mm (80–100W GaN) (RSBUCMKAGB11)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-median-buc-1-1-redundant-switch-system\"\u003eCompare all 16 Norsat MEDIAN BUC 1:1 Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSBUCMKAGD11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat MEDIAN Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC enclosure\u003c\/th\u003e\n\u003ctd\u003e411 × 254 mm (125–160W GaN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable power\u003c\/th\u003e\n\u003ctd\u003e125,160W GaN, including multibands (Includes Quad-band 100W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBUC unit size\u003c\/th\u003e\n\u003ctd\u003e411 x 254 x 259 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e950–2150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication frequency range\u003c\/th\u003e\n\u003ctd\u003e580–720 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e10MHz reference insertion loss\u003c\/th\u003e\n\u003ctd\u003e4 dB Max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFSK communication insertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (36MHz)\u003c\/th\u003e\n\u003ctd\u003e1 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e2 dB p-p max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e5 dB max (includes split)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.5 : 1 max for N Connector; 2.0 : 1 max for F Connector; 2.0 : 1 max for F Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch frequency\u003c\/th\u003e\n\u003ctd\u003e26.50–40.00 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch insertion loss\u003c\/th\u003e\n\u003ctd\u003e0.15 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch isolation\u003c\/th\u003e\n\u003ctd\u003e60 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch VSWR\u003c\/th\u003e\n\u003ctd\u003e1.10 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eProvided by the MEDIAN BUCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003ePower, A and B Alarm, Ethernet Activity (A side, B side, User Interface Ethernet (RJ-45), User Interface (Circular Connector), AUX Ethernet), A and B online, Multiband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide\u003c\/th\u003e\n\u003ctd\u003eWR28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveguide switch switching time\u003c\/th\u003e\n\u003ctd\u003e80 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWG switch control\u003c\/th\u003e\n\u003ctd\u003ePulse for WG switch generated at the IBUCs. Manual\/Auto: Controller pulses WG switch; emergency: toggle trigers pulse for WG switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eRJ-45 (J8 and J10); PT02E-14–19S (J9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM and c interface\u003c\/th\u003e\n\u003ctd\u003eEthernet, RS232\/485, Handheld terminal (applicable to both A and B sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSummary alarm\u003c\/th\u003e\n\u003ctd\u003eA and B Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e3,000 m ASL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eA and B L-Band Input Composite Level, 10 MHz Reference Level Detectors for: External demodulator, External reference, Internal reference (single or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517620090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSBUCMKAGD11%20MEDIAN%20BUC%201%3A1%20Redundant%20Switch%20System\u0026amp;mpn=RSBUCMKAGD11\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280111471,"sku":"NOR-RSBUCMKAGD11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-median-buc-1-1-redundant-switch-system.jpg?v=1793924210"},{"product_id":"norsat-rslnaku11r3","title":"Norsat RSLNAKU11R3 LNA Redundant Switch System, 1:1, Ku-Band, Rx only + 30m IFL","description":"\u003cp\u003eThe Norsat RSLNAKU11R3 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ku-Band; Tx\/Rx config + IFL length: Rx only + 30m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku12r3\"\u003e1:2 (RSLNAKU12R3)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11r3\"\u003eKa-Band (RSLNAKA11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11r3\"\u003eC-Band (RSLNAC11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11r3\"\u003eX-Band (RSLNAX11R3)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11r5\"\u003eRx only + 50m IFL (RSLNAKU11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11r10\"\u003eRx only + 100m IFL (RSLNAKU11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t3\"\u003eTx\/Rx + 30m IFL (RSLNAKU11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t5\"\u003eTx\/Rx + 50m IFL (RSLNAKU11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t10\"\u003eTx\/Rx + 100m IFL (RSLNAKU11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKU11R3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eRx only + 30m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKu-Band: WR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eRx Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKU11R3%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKU11R3\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280144239,"sku":"NOR-RSLNAKU11R3","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaku12r3","title":"Norsat RSLNAKU12R3 LNA Redundant Switch System, 1:2, Ku-Band, Rx only + 30m IFL","description":"\u003cp\u003eThe Norsat RSLNAKU12R3 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:2; Band: Ku-Band; Tx\/Rx config + IFL length: Rx only + 30m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:2.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11r3\"\u003e1:1 (RSLNAKU11R3)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka12r3\"\u003eKa-Band (RSLNAKA12R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac12r3\"\u003eC-Band (RSLNAC12R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax12r3\"\u003eX-Band (RSLNAX12R3)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku12r5\"\u003eRx only + 50m IFL (RSLNAKU12R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku12r10\"\u003eRx only + 100m IFL (RSLNAKU12R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku12t3\"\u003eTx\/Rx + 30m IFL (RSLNAKU12T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku12t5\"\u003eTx\/Rx + 50m IFL (RSLNAKU12T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku12t10\"\u003eTx\/Rx + 100m IFL (RSLNAKU12T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKU12R3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eRx only + 30m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKu-Band: WR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eRx Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKU12R3%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKU12R3\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280177007,"sku":"NOR-RSLNAKU12R3","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaku11r5","title":"Norsat RSLNAKU11R5 LNA Redundant Switch System, 1:1, Ku-Band, Rx only + 50m IFL","description":"\u003cp\u003eThe Norsat RSLNAKU11R5 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ku-Band; Tx\/Rx config + IFL length: Rx only + 50m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku12r5\"\u003e1:2 (RSLNAKU12R5)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11r5\"\u003eKa-Band (RSLNAKA11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11r5\"\u003eC-Band (RSLNAC11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11r5\"\u003eX-Band (RSLNAX11R5)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11r3\"\u003eRx only + 30m IFL (RSLNAKU11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11r10\"\u003eRx only + 100m IFL (RSLNAKU11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t3\"\u003eTx\/Rx + 30m IFL (RSLNAKU11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t5\"\u003eTx\/Rx + 50m IFL (RSLNAKU11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t10\"\u003eTx\/Rx + 100m IFL (RSLNAKU11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKU11R5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eRx only + 50m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e50m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKu-Band: WR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eRx Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKU11R5%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKU11R5\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280209775,"sku":"NOR-RSLNAKU11R5","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaku11r10","title":"Norsat RSLNAKU11R10 LNA Redundant Switch System, 1:1, Ku-Band, Rx only + 100m IFL","description":"\u003cp\u003eThe Norsat RSLNAKU11R10 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ku-Band; Tx\/Rx config + IFL length: Rx only + 100m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku12r10\"\u003e1:2 (RSLNAKU12R10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11r10\"\u003eKa-Band (RSLNAKA11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11r10\"\u003eC-Band (RSLNAC11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11r10\"\u003eX-Band (RSLNAX11R10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11r3\"\u003eRx only + 30m IFL (RSLNAKU11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11r5\"\u003eRx only + 50m IFL (RSLNAKU11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t3\"\u003eTx\/Rx + 30m IFL (RSLNAKU11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t5\"\u003eTx\/Rx + 50m IFL (RSLNAKU11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t10\"\u003eTx\/Rx + 100m IFL (RSLNAKU11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKU11R10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eRx only + 100m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e100m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKu-Band: WR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eRx Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKU11R10%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKU11R10\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280242543,"sku":"NOR-RSLNAKU11R10","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaku11t3","title":"Norsat RSLNAKU11T3 LNA Redundant Switch System, 1:1, Ku-Band, Tx\/Rx + 30m IFL","description":"\u003cp\u003eThe Norsat RSLNAKU11T3 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ku-Band; Tx\/Rx config + IFL length: Tx\/Rx + 30m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku12t3\"\u003e1:2 (RSLNAKU12T3)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11t3\"\u003eKa-Band (RSLNAKA11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11t3\"\u003eC-Band (RSLNAC11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11t3\"\u003eX-Band (RSLNAX11T3)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11r3\"\u003eRx only + 30m IFL (RSLNAKU11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11r5\"\u003eRx only + 50m IFL (RSLNAKU11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11r10\"\u003eRx only + 100m IFL (RSLNAKU11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t5\"\u003eTx\/Rx + 50m IFL (RSLNAKU11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t10\"\u003eTx\/Rx + 100m IFL (RSLNAKU11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKU11T3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eTx\/Rx + 30m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKu-Band: WR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eTx \/ Rx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKU11T3%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKU11T3\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280275311,"sku":"NOR-RSLNAKU11T3","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaku11t5","title":"Norsat RSLNAKU11T5 LNA Redundant Switch System, 1:1, Ku-Band, Tx\/Rx + 50m IFL","description":"\u003cp\u003eThe Norsat RSLNAKU11T5 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ku-Band; Tx\/Rx config + IFL length: Tx\/Rx + 50m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku12t5\"\u003e1:2 (RSLNAKU12T5)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11t5\"\u003eKa-Band (RSLNAKA11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11t5\"\u003eC-Band (RSLNAC11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11t5\"\u003eX-Band (RSLNAX11T5)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11r3\"\u003eRx only + 30m IFL (RSLNAKU11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11r5\"\u003eRx only + 50m IFL (RSLNAKU11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11r10\"\u003eRx only + 100m IFL (RSLNAKU11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t3\"\u003eTx\/Rx + 30m IFL (RSLNAKU11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t10\"\u003eTx\/Rx + 100m IFL (RSLNAKU11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKU11T5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eTx\/Rx + 50m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e50m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKu-Band: WR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eTx \/ Rx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKU11T5%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKU11T5\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280340847,"sku":"NOR-RSLNAKU11T5","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaku11t10","title":"Norsat RSLNAKU11T10 LNA Redundant Switch System, 1:1, Ku-Band, Tx\/Rx + 100m IFL","description":"\u003cp\u003eThe Norsat RSLNAKU11T10 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ku-Band; Tx\/Rx config + IFL length: Tx\/Rx + 100m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku12t10\"\u003e1:2 (RSLNAKU12T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11t10\"\u003eKa-Band (RSLNAKA11T10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11t10\"\u003eC-Band (RSLNAC11T10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11t10\"\u003eX-Band (RSLNAX11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11r3\"\u003eRx only + 30m IFL (RSLNAKU11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11r5\"\u003eRx only + 50m IFL (RSLNAKU11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11r10\"\u003eRx only + 100m IFL (RSLNAKU11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t3\"\u003eTx\/Rx + 30m IFL (RSLNAKU11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaku11t5\"\u003eTx\/Rx + 50m IFL (RSLNAKU11T5)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKU11T10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eTx\/Rx + 100m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e100m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKu-Band: WR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eTx \/ Rx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKU11T10%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKU11T10\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280373615,"sku":"NOR-RSLNAKU11T10","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaka11r3","title":"Norsat RSLNAKA11R3 LNA Redundant Switch System, 1:1, Ka-Band, Rx only + 30m IFL","description":"\u003cp\u003eThe Norsat RSLNAKA11R3 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ka-Band; Tx\/Rx config + IFL length: Rx only + 30m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka12r3\"\u003e1:2 (RSLNAKA12R3)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11r3\"\u003eKu-Band (RSLNAKU11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11r3\"\u003eC-Band (RSLNAC11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11r3\"\u003eX-Band (RSLNAX11R3)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11r5\"\u003eRx only + 50m IFL (RSLNAKA11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11r10\"\u003eRx only + 100m IFL (RSLNAKA11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t3\"\u003eTx\/Rx + 30m IFL (RSLNAKA11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t5\"\u003eTx\/Rx + 50m IFL (RSLNAKA11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t10\"\u003eTx\/Rx + 100m IFL (RSLNAKA11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKA11R3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eRx only + 30m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKa-Band: WR-42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eRx Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKA11R3%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKA11R3\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280406383,"sku":"NOR-RSLNAKA11R3","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaka11r5","title":"Norsat RSLNAKA11R5 LNA Redundant Switch System, 1:1, Ka-Band, Rx only + 50m IFL","description":"\u003cp\u003eThe Norsat RSLNAKA11R5 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ka-Band; Tx\/Rx config + IFL length: Rx only + 50m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka12r5\"\u003e1:2 (RSLNAKA12R5)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11r5\"\u003eKu-Band (RSLNAKU11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11r5\"\u003eC-Band (RSLNAC11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11r5\"\u003eX-Band (RSLNAX11R5)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11r3\"\u003eRx only + 30m IFL (RSLNAKA11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11r10\"\u003eRx only + 100m IFL (RSLNAKA11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t3\"\u003eTx\/Rx + 30m IFL (RSLNAKA11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t5\"\u003eTx\/Rx + 50m IFL (RSLNAKA11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t10\"\u003eTx\/Rx + 100m IFL (RSLNAKA11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKA11R5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eRx only + 50m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e50m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKa-Band: WR-42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eRx Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKA11R5%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKA11R5\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280439151,"sku":"NOR-RSLNAKA11R5","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaka11r10","title":"Norsat RSLNAKA11R10 LNA Redundant Switch System, 1:1, Ka-Band, Rx only + 100m IFL","description":"\u003cp\u003eThe Norsat RSLNAKA11R10 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ka-Band; Tx\/Rx config + IFL length: Rx only + 100m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka12r10\"\u003e1:2 (RSLNAKA12R10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11r10\"\u003eKu-Band (RSLNAKU11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11r10\"\u003eC-Band (RSLNAC11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11r10\"\u003eX-Band (RSLNAX11R10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11r3\"\u003eRx only + 30m IFL (RSLNAKA11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11r5\"\u003eRx only + 50m IFL (RSLNAKA11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t3\"\u003eTx\/Rx + 30m IFL (RSLNAKA11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t5\"\u003eTx\/Rx + 50m IFL (RSLNAKA11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t10\"\u003eTx\/Rx + 100m IFL (RSLNAKA11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKA11R10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eRx only + 100m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e100m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKa-Band: WR-42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eRx Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKA11R10%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKA11R10\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280471919,"sku":"NOR-RSLNAKA11R10","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaka11t3","title":"Norsat RSLNAKA11T3 LNA Redundant Switch System, 1:1, Ka-Band, Tx\/Rx + 30m IFL","description":"\u003cp\u003eThe Norsat RSLNAKA11T3 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ka-Band; Tx\/Rx config + IFL length: Tx\/Rx + 30m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka12t3\"\u003e1:2 (RSLNAKA12T3)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11t3\"\u003eKu-Band (RSLNAKU11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11t3\"\u003eC-Band (RSLNAC11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11t3\"\u003eX-Band (RSLNAX11T3)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11r3\"\u003eRx only + 30m IFL (RSLNAKA11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11r5\"\u003eRx only + 50m IFL (RSLNAKA11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11r10\"\u003eRx only + 100m IFL (RSLNAKA11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t5\"\u003eTx\/Rx + 50m IFL (RSLNAKA11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t10\"\u003eTx\/Rx + 100m IFL (RSLNAKA11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKA11T3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eTx\/Rx + 30m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKa-Band: WR-42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eTx \/ Rx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKA11T3%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKA11T3\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280504687,"sku":"NOR-RSLNAKA11T3","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaka11t5","title":"Norsat RSLNAKA11T5 LNA Redundant Switch System, 1:1, Ka-Band, Tx\/Rx + 50m IFL","description":"\u003cp\u003eThe Norsat RSLNAKA11T5 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ka-Band; Tx\/Rx config + IFL length: Tx\/Rx + 50m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka12t5\"\u003e1:2 (RSLNAKA12T5)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11t5\"\u003eKu-Band (RSLNAKU11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11t5\"\u003eC-Band (RSLNAC11T5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11t5\"\u003eX-Band (RSLNAX11T5)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11r3\"\u003eRx only + 30m IFL (RSLNAKA11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11r5\"\u003eRx only + 50m IFL (RSLNAKA11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11r10\"\u003eRx only + 100m IFL (RSLNAKA11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t3\"\u003eTx\/Rx + 30m IFL (RSLNAKA11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t10\"\u003eTx\/Rx + 100m IFL (RSLNAKA11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKA11T5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eTx\/Rx + 50m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e50m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKa-Band: WR-42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eTx \/ Rx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKA11T5%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKA11T5\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280570223,"sku":"NOR-RSLNAKA11T5","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"},{"product_id":"norsat-rslnaka11t10","title":"Norsat RSLNAKA11T10 LNA Redundant Switch System, 1:1, Ka-Band, Tx\/Rx + 100m IFL","description":"\u003cp\u003eThe Norsat RSLNAKA11T10 is an LNA Redundant Switch System from Norsat's LNA Redundant Switch range. It detects a failed LNA and switches to a standby unit in 120 ms or less, maximizing receive availability.\u003c\/p\u003e\u003cp\u003eThis configuration: Redundancy: 1:1; Band: Ka-Band; Tx\/Rx config + IFL length: Tx\/Rx + 100m IFL. Key specs: Switchover time: 120 ms max; Insertion loss: 0.5 dB max; Redundancy: 1:1.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The LNA Redundant Switch Series comes in 48 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka12t10\"\u003e1:2 (RSLNAKA12T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBand:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaku11t10\"\u003eKu-Band (RSLNAKU11T10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnac11t10\"\u003eC-Band (RSLNAC11T10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnax11t10\"\u003eX-Band (RSLNAX11T10)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTx\/Rx config + IFL length:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-rslnaka11r3\"\u003eRx only + 30m IFL (RSLNAKA11R3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11r5\"\u003eRx only + 50m IFL (RSLNAKA11R5)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11r10\"\u003eRx only + 100m IFL (RSLNAKA11R10)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t3\"\u003eTx\/Rx + 30m IFL (RSLNAKA11T3)\u003c\/a\u003e · \u003ca href=\"\/products\/norsat-rslnaka11t5\"\u003eTx\/Rx + 50m IFL (RSLNAKA11T5)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-lna-redundant-switch-system\"\u003eCompare all 48 Norsat LNA Redundant Switch System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRSLNAKA11T10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat LNA Redundant Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx\/Rx config + IFL length\u003c\/th\u003e\n\u003ctd\u003eTx\/Rx + 100m IFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitchover time\u003c\/th\u003e\n\u003ctd\u003e120 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003eLNB Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e0.5 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e90–264 VAC (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eLNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIFL cable length\u003c\/th\u003e\n\u003ctd\u003e100m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eKa-Band: WR-42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTx rx configuration\u003c\/th\u003e\n\u003ctd\u003eTx \/ Rx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e26 x 23 x 27 in (661 x 584 x 686 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e483 × 159 × 295 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDesigning a redundant earth station?\u003c\/h3\u003e\u003cp\u003eDigisat engineers design, install and commission 1:1 and 1:2 redundant transmit and receive chains for teleports, gateways and government sites, including switch integration, M\u0026amp;C and failover testing. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20RSLNAKA11T10%20LNA%20Redundant%20Switch%20System\u0026amp;mpn=RSLNAKA11T10\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964280602991,"sku":"NOR-RSLNAKA11T10","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-lna-redundant-switch-system.png?v=1793924210"}],"url":"https:\/\/digisat.org\/collections\/redundancy-switches.oembed","provider":"Digisat International","version":"1.0","type":"link"}