{"title":"Q-Band LNBs","description":"\u003cp\u003eQ-band LNBs convert 37.5–42.5 GHz downlinks to an IF for gateways and experimental high-frequency links.\u003c\/p\u003e\u003cp\u003eDigisat supplies Q-band LNBs from Norsat and Orbital Research with quote-based pricing for government, teleport and enterprise buyers, accepts purchase orders and GPC, and our engineers can help size, integrate, install and support the equipment. Browse 3 part numbers below, or ask us for a configuration that is not listed.\u003c\/p\u003e","products":[{"product_id":"norsat-q1000hf","title":"Norsat Q1000HF Q-Band PLL LNB, 40.50–41.00 GHz, ±50 kHz, F-Type","description":"\u003cp\u003eThe Norsat Q1000HF is a Q-Band PLL LNB from Norsat's Q1000H Series. It converts 40.50–41.00 GHz to an L-band output of 950–1450 MHz using a 39.55 GHz PLL local oscillator.\u003c\/p\u003e\u003cp\u003eThis model has a 3 dB maximum noise figure, holds ±50 kHz frequency stability, and has an F-type (75 Ω) IF output.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The Q1000H Series comes in 2 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eOutput connector:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-q1000hn\"\u003eType-N (50 Ω) (Q1000HN)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-q1000h-q-band-pll-lnb\"\u003eCompare all 2 Norsat Q1000H Q-Band PLL LNB models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eQ1000HF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat Q1000H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency plan\u003c\/th\u003e\n\u003ctd\u003e40.50–41.00 GHz → LO 39.55 GHz → IF 950–1450 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise figure\u003c\/th\u003e\n\u003ctd\u003e3 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e±50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput connector\u003c\/th\u003e\n\u003ctd\u003eF-type (75 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConversion gain (max.)\u003c\/th\u003e\n\u003ctd\u003e60 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConversion gain (min.)\u003c\/th\u003e\n\u003ctd\u003e50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain Flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e≤ 3 dB p-p max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e2.0 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput P1dB (min.)\u003c\/th\u003e\n\u003ctd\u003e+5 dBm min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.8 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise @ 1 kHz (max.)\u003c\/th\u003e\n\u003ctd\u003e-70 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise @ 10 kHz (max.)\u003c\/th\u003e\n\u003ctd\u003e-80 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise @ 100 kHz (max.)\u003c\/th\u003e\n\u003ctd\u003e-90 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd\u003e1000 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower requirements\u003c\/th\u003e\n\u003ctd\u003e+8 to +13 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eWR-22 waveguide grooved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, storage\u003c\/th\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e146 × 55 × 39 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eRepublic of Korea\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBuilding a Q-band receive chain?\u003c\/h3\u003e\u003cp\u003eDigisat engineers help design, integrate and commission high-frequency ground systems for government, research and gateway customers. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20Q1000HF%20Q-Band%20PLL%20LNB\u0026amp;mpn=Q1000HF\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964243968367,"sku":"NOR-Q1000HF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-q1000h-q-band-pll-lnb.png?v=1793910597"},{"product_id":"norsat-q1000hn","title":"Norsat Q1000HN Q-Band PLL LNB, 40.50–41.00 GHz, ±50 kHz, Type-N","description":"\u003cp\u003eThe Norsat Q1000HN is a Q-Band PLL LNB from Norsat's Q1000H Series. It converts 40.50–41.00 GHz to an L-band output of 950–1450 MHz using a 39.55 GHz PLL local oscillator.\u003c\/p\u003e\u003cp\u003eThis model has a 3 dB maximum noise figure, holds ±50 kHz frequency stability, and has a Type-N (50 Ω) IF output.\u003c\/p\u003e\u003cp\u003eNeed a different configuration? The Q1000H Series comes in 2 part numbers. Compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther configurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eOutput connector:\u003c\/strong\u003e \u003ca href=\"\/products\/norsat-q1000hf\"\u003eF-type (75 Ω) (Q1000HF)\u003c\/a\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/norsat-q1000h-q-band-pll-lnb\"\u003eCompare all 2 Norsat Q1000H Q-Band PLL LNB models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eQ1000HN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNorsat Q1000H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency plan\u003c\/th\u003e\n\u003ctd\u003e40.50–41.00 GHz → LO 39.55 GHz → IF 950–1450 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise figure\u003c\/th\u003e\n\u003ctd\u003e3 dB max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO stability\u003c\/th\u003e\n\u003ctd\u003e±50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput connector\u003c\/th\u003e\n\u003ctd\u003eType-N (50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConversion gain (max.)\u003c\/th\u003e\n\u003ctd\u003e60 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConversion gain (min.)\u003c\/th\u003e\n\u003ctd\u003e50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain Flatness (over full band)\u003c\/th\u003e\n\u003ctd\u003e≤ 3 dB p-p max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e2.0 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput P1dB (min.)\u003c\/th\u003e\n\u003ctd\u003e+5 dBm min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.8 : 1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise @ 1 kHz (max.)\u003c\/th\u003e\n\u003ctd\u003e-70 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise @ 10 kHz (max.)\u003c\/th\u003e\n\u003ctd\u003e-80 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise @ 100 kHz (max.)\u003c\/th\u003e\n\u003ctd\u003e-90 dBc\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd\u003e1000 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower requirements\u003c\/th\u003e\n\u003ctd\u003e+8 to +13 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eWR-22 waveguide grooved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, operational\u003c\/th\u003e\n\u003ctd\u003e-40 to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature, storage\u003c\/th\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e146 × 55 × 39 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompliance and export\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of origin\u003c\/th\u003e\n\u003ctd\u003eRepublic of Korea\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECCN\u003c\/th\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHS code\u003c\/th\u003e\n\u003ctd\u003e8517690000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBuilding a Q-band receive chain?\u003c\/h3\u003e\u003cp\u003eDigisat engineers help design, integrate and commission high-frequency ground systems for government, research and gateway customers. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Norsat%20Q1000HN%20Q-Band%20PLL%20LNB\u0026amp;mpn=Q1000HN\"\u003eTalk to an engineer\u003c\/a\u003e.\u003c\/p\u003e","brand":"Norsat","offers":[{"title":"Default Title","offer_id":67964244033903,"sku":"NOR-Q1000HN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/norsat-q1000h-q-band-pll-lnb.png?v=1793910597"},{"product_id":"orbital-research-lnbqsc-xiws60a","title":"Orbital Research LNBQSC-XIWS60A Q-Band LNB","description":"\u003cp\u003eAn external-reference dual-LO Q-band LNB that switches between bands from 37.5 to 42.5 GHz, with high gain and under 2.5 dB noise figure, for teleports, gateways, TT\u0026amp;C and airborne terminals.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLNBQSC-XIWS60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eOrbital Research Q-Band LNB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF Frequency Band 1 (GHz)\u003c\/th\u003e\n\u003ctd\u003e37.5 to 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO Frequency Band 1 (GHz)\u003c\/th\u003e\n\u003ctd\u003e36.5 (switchable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF Frequency Band 2 (GHz)\u003c\/th\u003e\n\u003ctd\u003e40 – 42.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO Frequency Band 2 (GHz)\u003c\/th\u003e\n\u003ctd\u003e43.5 (switchable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBandwidth (MHz)\u003c\/th\u003e\n\u003ctd\u003e2500 per band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise Figure (dB)\u003c\/th\u003e\n\u003ctd\u003e2.5 @ 25C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e1.5:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e1.5:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain (dB)\u003c\/th\u003e\n\u003ctd\u003e55 – 65 (DSA Gain Step 0.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlatness (dB)\u003c\/th\u003e\n\u003ctd\u003e± 2 per band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVariation over temp (dB)\u003c\/th\u003e\n\u003ctd\u003e± 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStability over Hrs (dB)\u003c\/th\u003e\n\u003ctd\u003e± 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImage Rejection (dBc) (max)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e1 dB Compression\u003c\/th\u003e\n\u003ctd\u003e(dB) (min) +10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOIP3 (dBm) (min)\u003c\/th\u003e\n\u003ctd\u003e+20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eMS Connector 4 pin Power Supply Alarm Current Alarm PLL Alarm Band Setting DSA Setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMTBF (\u0026gt; Hrs)\u003c\/th\u003e\n\u003ctd\u003e250,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eIP65 ROHs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temperature (deg C)\u003c\/th\u003e\n\u003ctd\u003e-40 to +60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature (deg C)\u003c\/th\u003e\n\u003ctd\u003e-40 to +85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity (%)\u003c\/th\u003e\n\u003ctd\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight (grams)\u003c\/th\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (mm)\u003c\/th\u003e\n\u003ctd\u003e170 x 55 x 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Connector\u003c\/th\u003e\n\u003ctd\u003eWR-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Connector\u003c\/th\u003e\n\u003ctd\u003eSMA-female (50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBand\u003c\/th\u003e\n\u003ctd\u003eQ-Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eDual LO, Voltage Control, Push Button, External Ref\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003ctd\u003ePush button, Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eExternal 10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003ch4\u003eDoes Digisat supply and support the Orbital Research Q-Band LNB?\u003c\/h4\u003e\u003cp\u003eYes. Digisat supplies Orbital Research equipment with quote-based pricing for government, teleport and enterprise buyers, and our engineers can help choose the configuration, integrate it and support it after installation.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=Orbital%20Research%20LNBQSC-XIWS60A%20Q-Band%20LNB\u0026amp;mpn=LNBQSC-XIWS60A\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"Orbital Research","offers":[{"title":"Default Title","offer_id":67976965325167,"sku":"ORB-LNBQSC-XIWS60A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/orbital-research-q-band-lnb.png?v=1793910596"}],"url":"https:\/\/digisat.org\/collections\/q-band-lnbs.oembed","provider":"Digisat International","version":"1.0","type":"link"}