Norsat Universal LNB Controller (ULC)

The Norsat Universal LNB Controller (ULC) sits inline on the IF cable and supplies everything a multi-band LNB needs: 13 V or 18 V band-select power at up to 500 mA, a 22 kHz tone, and an optional 10 MHz reference. That's ideal when your receiver or splitter can't provide them. Choose no reference, a built-in 10 MHz reference or a 10 MHz injection port, along with F-type, N-type or SMA connectors and switch, cable or line-length-compensation control.

Key features

  • 13 V / 18 V LNB band-select power, 500 mA maximum
  • 22 kHz tone (20–24 kHz, 0.55–0.9 Vpp)
  • Optional built-in 10 MHz reference or 10 MHz injection port (F, N or SMA)
  • Control by switch, control-interface cable or line-length compensation
  • F-type (75 Ω), N-type or SMA (50 Ω) connectors
  • +23 to +25 VDC input; IP66, −30 °C to +60 °C; 3-year warranty

Norsat Universal LNB Controller (ULC) products

Skip to results list

Active filters:

45 items
Column grid
Column grid

Filter

Active filters:

Configuration options

ReferenceNo Reference · 10 MHz reference · 10 MHz injection port (F Connector) · 10 MHz injection port (N Connector) · 10 MHz injection port (SMA Connector)
ConnectorSMA (50 Ω) · Type-N (50 Ω) · F-type (75 Ω)
Control interfaceBlank: Switch Control Only · Control Interface Cable · Line Length Compensation with Switch

All 45 part numbers

Part numberReferenceConnectorControl interface
ULC-0-50No ReferenceType-N (50 Ω)Blank: Switch Control Only
ULC-0-50-CINo ReferenceType-N (50 Ω)Control Interface Cable
ULC-0-50-LLCNo ReferenceType-N (50 Ω)Line Length Compensation with Switch
ULC-0-50sNo ReferenceSMA (50 Ω)Blank: Switch Control Only
ULC-0-50s-CINo ReferenceSMA (50 Ω)Control Interface Cable
ULC-0-50s-LLCNo ReferenceSMA (50 Ω)Line Length Compensation with Switch
ULC-0-75No ReferenceF-type (75 Ω)Blank: Switch Control Only
ULC-0-75-CINo ReferenceF-type (75 Ω)Control Interface Cable
ULC-0-75-LLCNo ReferenceF-type (75 Ω)Line Length Compensation with Switch
ULC-1-5010 MHz referenceType-N (50 Ω)Blank: Switch Control Only
ULC-1-50-CI10 MHz referenceType-N (50 Ω)Control Interface Cable
ULC-1-50-LLC10 MHz referenceType-N (50 Ω)Line Length Compensation with Switch
ULC-1-50s10 MHz referenceSMA (50 Ω)Blank: Switch Control Only
ULC-1-50s-CI10 MHz referenceSMA (50 Ω)Control Interface Cable
ULC-1-50s-LLC10 MHz referenceSMA (50 Ω)Line Length Compensation with Switch
ULC-1-7510 MHz referenceF-type (75 Ω)Blank: Switch Control Only
ULC-1-75-CI10 MHz referenceF-type (75 Ω)Control Interface Cable
ULC-1-75-LLC10 MHz referenceF-type (75 Ω)Line Length Compensation with Switch
ULC-2F-5010 MHz injection port (F Connector)Type-N (50 Ω)Blank: Switch Control Only
ULC-2F-50-CI10 MHz injection port (F Connector)Type-N (50 Ω)Control Interface Cable
ULC-2F-50-LLC10 MHz injection port (F Connector)Type-N (50 Ω)Line Length Compensation with Switch
ULC-2F-50s10 MHz injection port (F Connector)SMA (50 Ω)Blank: Switch Control Only
ULC-2F-50s-CI10 MHz injection port (F Connector)SMA (50 Ω)Control Interface Cable
ULC-2F-50s-LLC10 MHz injection port (F Connector)SMA (50 Ω)Line Length Compensation with Switch
ULC-2F-7510 MHz injection port (F Connector)F-type (75 Ω)Blank: Switch Control Only
ULC-2F-75-CI10 MHz injection port (F Connector)F-type (75 Ω)Control Interface Cable
ULC-2F-75-LLC10 MHz injection port (F Connector)F-type (75 Ω)Line Length Compensation with Switch
ULC-2N-5010 MHz injection port (N Connector)Type-N (50 Ω)Blank: Switch Control Only
ULC-2N-50-CI10 MHz injection port (N Connector)Type-N (50 Ω)Control Interface Cable
ULC-2N-50-LLC10 MHz injection port (N Connector)Type-N (50 Ω)Line Length Compensation with Switch
ULC-2N-50s10 MHz injection port (N Connector)SMA (50 Ω)Blank: Switch Control Only
ULC-2N-50s-CI10 MHz injection port (N Connector)SMA (50 Ω)Control Interface Cable
ULC-2N-50s-LLC10 MHz injection port (N Connector)SMA (50 Ω)Line Length Compensation with Switch
ULC-2N-7510 MHz injection port (N Connector)F-type (75 Ω)Blank: Switch Control Only
ULC-2N-75-CI10 MHz injection port (N Connector)F-type (75 Ω)Control Interface Cable
ULC-2N-75-LLC10 MHz injection port (N Connector)F-type (75 Ω)Line Length Compensation with Switch
ULC-2S-5010 MHz injection port (SMA Connector)Type-N (50 Ω)Blank: Switch Control Only
ULC-2S-50-CI10 MHz injection port (SMA Connector)Type-N (50 Ω)Control Interface Cable
ULC-2S-50-LLC10 MHz injection port (SMA Connector)Type-N (50 Ω)Line Length Compensation with Switch
ULC-2S-50s10 MHz injection port (SMA Connector)SMA (50 Ω)Blank: Switch Control Only
ULC-2S-50s-CI10 MHz injection port (SMA Connector)SMA (50 Ω)Control Interface Cable
ULC-2S-50s-LLC10 MHz injection port (SMA Connector)SMA (50 Ω)Line Length Compensation with Switch
ULC-2S-7510 MHz injection port (SMA Connector)F-type (75 Ω)Blank: Switch Control Only
ULC-2S-75-CI10 MHz injection port (SMA Connector)F-type (75 Ω)Control Interface Cable
ULC-2S-75-LLC10 MHz injection port (SMA Connector)F-type (75 Ω)Line Length Compensation with Switch

Specifications

CI option logic levelsL: 0–0.8 V; H: 2.5–7 V (20mA)
Reference signalNone / 10MHz internal / 10MHz injection port (varies by model)
Tone amplitude0.55 ~ 0.9 vpp
Tone frequency20 ~ 24 kHz
Current consumption450 mA/24 VDC / 600 mA/24 VDC (varies by model)
Output current500 mA max.
Output voltage range band 112.5 ~ 13.5 VDC
Output voltage range band 217.3 ~ 18.7 VDC
Power requirements+23 to +25 VDC
ConnectorF-Connector / N-Connector / SMA Connector (varies by model)
Control interfaceSwitch, Cable, Line Length Compensation with switch
RF input75 Ohm F Connector / 50 Ohm N Connector / 50 Ohm SMA Connector (varies by model)
IP ratingIP 66
Temperature, operational-30 to +60 °C
Product weight0.66 kg
Dimensions (L × W × H)130 × 95 × 30 mm

Compliance and export

Country of originCanada
ECCNEAR99
HS code8517690000
Warranty3 years

Frequently asked questions

When do I need an LNB controller?

When the equipment on the IF cable, such as a splitter, distribution amplifier or test receiver, can't supply the voltage, tone or 10 MHz reference a multi-band or external-reference LNB needs.

What does line-length compensation do?

On long IF runs, voltage drop can stop the LNB from seeing the correct 13/18 V select level. The LLC option raises the output to compensate.

Need help with a multi-band receive setup?

Digisat engineers configure LNB power, band switching and 10 MHz reference distribution for teleports, monitoring stations and government terminals. Talk to an engineer.