{"title":"CPI TL02VO V-Band TWTAs","description":null,"products":[{"product_id":"cpi-tl02vo-a1","title":"CPI TL02VO-A1 250W V-Band Outdoor TWTA, 47.2–52.4 GHz","description":"\u003cp\u003eThe CPI TL02VO-A1 is a 250W V-Band air-cooled outdoor TWTA. It delivers 250W peak at the TWT flange, 200W peak at the amplifier flange and 80W rated linear power across 47.2–51.4 or 47.2–52.4 GHz.\u003c\/p\u003e\u003cp\u003eWith the linearizer, intermodulation is -28 dBc and NPR 19 dB at 80W. It runs on 100–240 VAC single phase (1100 VA max.) and weighs 65 lb.\u003c\/p\u003e\u003cp\u003eOrder it as TL02VO-A1. The Outdoor V-Band TWTA Series comes in 2 listed models; compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther models in this series\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/cpi-tl02vo-l1\"\u003eTL02VO-L1\u003c\/a\u003e: Liquid-cooled\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/cpi-outdoor-v-band-twta-series-v-band-twta\"\u003eCompare all 2 CPI TL02VO V-Band TWTAs models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eTL02VO-A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eCPI Outdoor V-Band TWTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e47.2–51.4 GHz or 47.2–52.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003ePeak TWT flange 250W (53.97 dBm); peak amplifier flange 200W (53.00 dBm); rated linear 80W (49.03 dBm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain\u003c\/th\u003e\n\u003ctd\u003e60 dB min.; 64 dB typ. at 3 dB backoff from rated CW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntermodulation (two carriers)\u003c\/th\u003e\n\u003ctd\u003e-28 dBc \/ -25 dBc max. at 80W total output with linearizer (two specified conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise power ratio\u003c\/th\u003e\n\u003ctd\u003e19 dB at 80W (75W with optional harmonic filter), with linearizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral regrowth\u003c\/th\u003e\n\u003ctd\u003e-30 dBc max. at rated CW power with linearizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrimary power\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC ±10%, single phase, 47–63 Hz; 1100 VA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eForced air, integral blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C to +55 °C in direct sun; to +60 °C out of sun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections\u003c\/th\u003e\n\u003ctd\u003eWR-22 cover-flange input and WR-22 grooved output (WR-19 optional); 1.85 mm female output monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eEthernet; RS-232\/422 optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (W × H × D)\u003c\/th\u003e\n\u003ctd\u003e10.25 × 11.37 × 22.25 in (261 × 289 × 566 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e65 lb (29.5 kg) nominal with options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=CPI%20TL02VO-A1%20250W%20V-Band%20Outdoor%20TWTA\u0026amp;mpn=TL02VO-A1\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"CPI","offers":[{"title":"Default Title","offer_id":67964375236975,"sku":"CPI-TL02VO-A1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/cpi-820-mkt-422-tl02vo-a1-250-w-v-band-twta-1600x1416.jpg?v=1793925976"},{"product_id":"cpi-tl02vo-l1","title":"CPI TL02VO-L1 250W V-Band Liquid-Cooled Outdoor TWTA, 47.2–52.4 GHz","description":"\u003cp\u003eThe CPI TL02VO-L1 is a 250W V-Band liquid-cooled outdoor TWTA. It delivers 250W peak at the TWT flange, 200W peak at the amplifier flange and 80W rated linear power across 47.2–51.4 or 47.2–52.4 GHz.\u003c\/p\u003e\u003cp\u003eLiquid cooling (at least 1 gallon per minute of water, up to 50% glycol) lowers power draw to 900 VA max. and makes it quieter than the air-cooled TL02VO-A1. It runs on 100–240 VAC single phase and weighs 67 lb.\u003c\/p\u003e\u003cp\u003eOrder it as TL02VO-L1. The Outdoor V-Band TWTA Series comes in 2 listed models; compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther models in this series\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/cpi-tl02vo-a1\"\u003eTL02VO-A1\u003c\/a\u003e: Air-cooled\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/cpi-outdoor-v-band-twta-series-v-band-twta\"\u003eCompare all 2 CPI TL02VO V-Band TWTAs models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eTL02VO-L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eCPI Outdoor V-Band TWTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e47.2–51.4 GHz or 47.2–52.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput power\u003c\/th\u003e\n\u003ctd\u003ePeak TWT flange 250W (53.97 dBm); peak amplifier flange 200W (53.00 dBm); rated linear 80W (49.03 dBm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain\u003c\/th\u003e\n\u003ctd\u003e60 dB min.; 64 dB typ. at 3 dB backoff from rated CW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntermodulation (two carriers)\u003c\/th\u003e\n\u003ctd\u003e-28 dBc \/ -25 dBc max. at 80W total output with linearizer (two specified conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise power ratio\u003c\/th\u003e\n\u003ctd\u003e19 dB at 80W (75W with optional harmonic filter), with linearizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectral regrowth\u003c\/th\u003e\n\u003ctd\u003e-30 dBc max. at rated CW power with linearizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrimary power\u003c\/th\u003e\n\u003ctd\u003e100–240 VAC ±10%, single phase, 47–63 Hz; 900 VA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eLiquid: 1 gallon per minute min. of water (up to 50% glycol), 60 °C max. at inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C to +55 °C in direct sun; to +60 °C out of sun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections\u003c\/th\u003e\n\u003ctd\u003eWR-22 cover-flange input and WR-22 grooved output (WR-19 optional); 1.85 mm female output monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003eEthernet; RS-232\/422 optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (W × H × D)\u003c\/th\u003e\n\u003ctd\u003e10.25 × 10.02 × 22.25 in (261 × 255 × 566 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e67 lb (30.4 kg) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=CPI%20TL02VO-L1%20250W%20V-Band%20Liquid-Cooled%20Outdoor%20TWTA\u0026amp;mpn=TL02VO-L1\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"CPI","offers":[{"title":"Default Title","offer_id":67964375269743,"sku":"CPI-TL02VO-L1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/cpi-820-mkt-492-tl02vo-l1-250-w-v-band-twta-1600x1416.jpg?v=1793925976"}],"url":"https:\/\/digisat.org\/collections\/cpi-outdoor-v-band-twta-series-v-band-twta.oembed","provider":"Digisat International","version":"1.0","type":"link"}