{"title":"CPI ModuMAX GaN Ku-Band SSPA Systems","description":null,"products":[{"product_id":"cpi-mpkog141100m","title":"CPI MPKOG141100M 1100W Ku-Band GaN SSPA, 13.75–14.50 GHz","description":"\u003cp\u003eThe CPI MPKOG141100M is a 1100W Ku-Band GaN SSPA system from CPI's ModuMAX GaN line. This single-HPA system delivers 1080W typical saturated (+60.3 dBm) and 540W minimum linear power (+57.3 dBm) across 13.75–14.50 GHz.\u003c\/p\u003e\u003cp\u003eEight identical GaN RF modules feed a passive waveguide combiner, and up to eight 48 VDC power supply modules share the load in an N+1 configuration. If a module fails, output drops by only about 1.2 dB until auto-recovery enables a spare or raises the gain of the remaining modules, and every major assembly hot-swaps from the front panel without taking the uplink down.\u003c\/p\u003e\u003cp\u003eOrder it as MPKOG141100M; rack integration, spares, maintenance switch, air-duct and phase-combining kits are ordered separately. The ModuMAX GaN Series comes in 2 listed models; compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther models in this series\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/cpi-mpkog141900m\"\u003eMPKOG141900M\u003c\/a\u003e: Phase-combined\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/cpi-modumax-gan-series-ku-band-sspa\"\u003eCompare all 2 CPI ModuMAX GaN Ku-Band SSPA Systems models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eMPKOG141100M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eCPI ModuMAX GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e13.75–14.50 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSaturated power\u003c\/th\u003e\n\u003ctd\u003e1080W typ. (+60.3 dBm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLinear power\u003c\/th\u003e\n\u003ctd\u003e540W min. (+57.3 dBm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain at maximum setting\u003c\/th\u003e\n\u003ctd\u003e60 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain vs. temperature (0–50 °C)\u003c\/th\u003e\n\u003ctd\u003e±0.75 dB max., ±0.5 dB typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain adjustment\u003c\/th\u003e\n\u003ctd\u003e20 dB min., digital, 0.1 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness\u003c\/th\u003e\n\u003ctd\u003e±1.0 dB full band; ±0.3 dB per 40 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVSWR (input and output)\u003c\/th\u003e\n\u003ctd\u003e1.2:1 typ., 1.3:1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample ports\u003c\/th\u003e\n\u003ctd\u003e-10 dBc input, -50 dBc output, typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC input\u003c\/th\u003e\n\u003ctd\u003e180–264 VAC, 47–63 Hz, single or three phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-45 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity \/ altitude\u003c\/th\u003e\n\u003ctd\u003e95% non-condensing; to 10,000 ft (3000 m), derate 2 °C per 1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTwo-tone IMD\u003c\/th\u003e\n\u003ctd\u003e-25 dBc max., -30 dBc typ. at rated linear power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResidual noise, 14.0–14.5 GHz\u003c\/th\u003e\n\u003ctd\u003e-70 dBW\/4 kHz max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGroup delay\u003c\/th\u003e\n\u003ctd\u003e0.03 ns\/MHz linear, 0.003 ns\/MHz² parabolic, 1.0 ns p-p ripple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAM\/PM conversion\u003c\/th\u003e\n\u003ctd\u003e1.0°\/dB typ. at rated linear power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSecond harmonic \/ spurious\u003c\/th\u003e\n\u003ctd\u003e-50 dBc max. \/ -70 dBc max. at rated linear power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower requirement\u003c\/th\u003e\n\u003ctd\u003e180–264 VAC, 47–63 Hz, PF 0.98 typ.; 7.4 kVA typ., 11 kVA max. at rated linear power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C to +50 °C inlet air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eType N female RF input and monitor ports; WR-75G output; RJ-45 network; D-sub serial, parallel I\/O and system; USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003ctd\u003eRF unit 16 RU: 19.0 W × 27.97 H × 29.37 D in; power supply 4 RU: 19.0 W × 6.97 H × 27.46 D in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eRF unit 388 lb (175 kg); power supply 103 lb (46 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=CPI%20MPKOG141100M%201100W%20Ku-Band%20GaN%20SSPA\u0026amp;mpn=MPKOG141100M\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"CPI","offers":[{"title":"Default Title","offer_id":67964366291311,"sku":"CPI-MPKOG141100M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/cpi-mpkog141100m-ku-band-sspa.png?v=1793924395"},{"product_id":"cpi-mpkog141900m","title":"CPI MPKOG141900M 1900W Ku-Band GaN SSPA, 13.75–14.50 GHz","description":"\u003cp\u003eThe CPI MPKOG141900M is a 1900W Ku-Band GaN SSPA system from CPI's ModuMAX GaN line. This phase-combined system pairs two ModuMAX GaN SSPAs to deliver 1900W saturated and 950W linear power across 13.75–14.50 GHz.\u003c\/p\u003e\u003cp\u003eEight identical GaN RF modules feed a passive waveguide combiner, and up to eight 48 VDC power supply modules share the load in an N+1 configuration. If a module fails, output drops by only about 1.2 dB until auto-recovery enables a spare or raises the gain of the remaining modules, and every major assembly hot-swaps from the front panel without taking the uplink down.\u003c\/p\u003e\u003cp\u003eOrder it as MPKOG141900M; rack integration, spares, maintenance switch, air-duct and phase-combining kits are ordered separately. The ModuMAX GaN Series comes in 2 listed models; compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther models in this series\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/cpi-mpkog141100m\"\u003eMPKOG141100M\u003c\/a\u003e: Single HPA\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/cpi-modumax-gan-series-ku-band-sspa\"\u003eCompare all 2 CPI ModuMAX GaN Ku-Band SSPA Systems models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eMPKOG141900M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eCPI ModuMAX GaN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e13.75–14.50 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSaturated power\u003c\/th\u003e\n\u003ctd\u003e1900W (phase-combined pair, per CPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLinear power\u003c\/th\u003e\n\u003ctd\u003e950W (per CPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain at maximum setting\u003c\/th\u003e\n\u003ctd\u003e60 dB min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain vs. temperature (0–50 °C)\u003c\/th\u003e\n\u003ctd\u003e±0.75 dB max., ±0.5 dB typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain adjustment\u003c\/th\u003e\n\u003ctd\u003e20 dB min., digital, 0.1 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness\u003c\/th\u003e\n\u003ctd\u003e±1.0 dB full band; ±0.3 dB per 40 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVSWR (input and output)\u003c\/th\u003e\n\u003ctd\u003e1.2:1 typ., 1.3:1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample ports\u003c\/th\u003e\n\u003ctd\u003e-10 dBc input, -50 dBc output, typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC input\u003c\/th\u003e\n\u003ctd\u003e180–264 VAC, 47–63 Hz, single or three phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-45 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity \/ altitude\u003c\/th\u003e\n\u003ctd\u003e95% non-condensing; to 10,000 ft (3000 m), derate 2 °C per 1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTwo-tone IMD\u003c\/th\u003e\n\u003ctd\u003e-25 dBc max., -30 dBc typ. at rated linear power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResidual noise, 14.0–14.5 GHz\u003c\/th\u003e\n\u003ctd\u003e-70 dBW\/4 kHz max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGroup delay\u003c\/th\u003e\n\u003ctd\u003e0.03 ns\/MHz linear, 0.003 ns\/MHz² parabolic, 1.0 ns p-p ripple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAM\/PM conversion\u003c\/th\u003e\n\u003ctd\u003e1.0°\/dB typ. at rated linear power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSecond harmonic \/ spurious\u003c\/th\u003e\n\u003ctd\u003e-50 dBc max. \/ -70 dBc max. at rated linear power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower requirement\u003c\/th\u003e\n\u003ctd\u003eTwo ModuMAX GaN SSPAs; each 180–264 VAC, 7.4 kVA typ., 11 kVA max. at rated linear power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C to +50 °C inlet air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eType N female RF input and monitor ports; WR-75G output; RJ-45 network; D-sub serial, parallel I\/O and system; USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003ctd\u003eTwo ModuMAX GaN SSPAs plus phase-combining kit; each RF unit 16 RU, power supply 4 RU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eEach SSPA: RF unit 388 lb (175 kg), power supply 103 lb (46 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=CPI%20MPKOG141900M%201900W%20Ku-Band%20GaN%20SSPA\u0026amp;mpn=MPKOG141900M\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"CPI","offers":[{"title":"Default Title","offer_id":67964366324079,"sku":"CPI-MPKOG141900M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/cpi-mpkog141100m-ku-band-sspa.png?v=1793924395"}],"url":"https:\/\/digisat.org\/collections\/cpi-modumax-gan-series-ku-band-sspa.oembed","provider":"Digisat International","version":"1.0","type":"link"}