CPI ModuMAX GaN Ku-Band SSPA Systems

CPI's ModuMAX GaN SSPA systems bring GaN reliability and linearity to high-power Ku-band uplinks. Eight hot-swappable RF modules and up to eight load-sharing power supplies sit behind a passive waveguide combiner with no single point of failure, so the SSPA stays on air through a module failure or replacement. A front-panel touch screen, embedded web interface with SNMPv3 and full remote control make it easy to run from anywhere, and two ModuMAX units can be phase-combined for multi-carrier power.

Key features

  • 1100W single-HPA (540W linear) or 1900W phase-combined (950W linear)
  • 13.75–14.50 GHz extended Ku-band
  • 8 hot-swappable GaN RF modules; passive waveguide combining with no single point of failure
  • Auto-recovery: about 1.2 dB drop on a module failure, no uplink interruption
  • N+1 load-sharing 48 VDC power supply modules, hot-swappable
  • Color touch-screen front panel; embedded web interface with SNMPv3
  • Network and RS-232/-422/-485 remote control; remote firmware upgrades
  • Three-year all-inclusive warranty

CPI ModuMAX GaN Ku-Band SSPA Systems products

Skip to results list

Active filters:

2 items
Column grid
Column grid

Filter

Active filters:

  • CPI MPKOG141100M 1100W Ku-Band GaN SSPA, 13.75–14.50 GHz

    CPI MPKOG141100M 1100W Ku-Band GaN SSPA, 13.75–14.50 GHz

    View specs & quote
  • CPI MPKOG141900M 1900W Ku-Band GaN SSPA, 13.75–14.50 GHz

    CPI MPKOG141900M 1900W Ku-Band GaN SSPA, 13.75–14.50 GHz

    View specs & quote

All 2 models

Part numberPsat (W)Linear (W)Configuration
MPKOG141100M1100540Single HPA
MPKOG141900M1900950Phase-combined

Specifications

Frequency range13.75–14.50 GHz
Saturated powerVaries by model; see the models table
Linear powerVaries by model; see the models table
Gain at maximum setting60 dB min.
Gain vs. temperature (0–50 °C)±0.75 dB max., ±0.5 dB typ.
Gain adjustment20 dB min., digital, 0.1 dB steps
Gain flatness±1.0 dB full band; ±0.3 dB per 40 MHz
VSWR (input and output)1.2:1 typ., 1.3:1 max.
Sample ports-10 dBc input, -50 dBc output, typ.
AC input180–264 VAC, 47–63 Hz, single or three phase
Storage temperature-45 °C to +85 °C
Humidity / altitude95% non-condensing; to 10,000 ft (3000 m), derate 2 °C per 1000 ft
Two-tone IMD-25 dBc max., -30 dBc typ. at rated linear power
Residual noise, 14.0–14.5 GHz-70 dBW/4 kHz max.
Group delay0.03 ns/MHz linear, 0.003 ns/MHz² parabolic, 1.0 ns p-p ripple
AM/PM conversion1.0°/dB typ. at rated linear power
Second harmonic / spurious-50 dBc max. / -70 dBc max. at rated linear power
Power requirementVaries by model; see the models table
Operating temperature0 °C to +50 °C inlet air
ConnectorsType N female RF input and monitor ports; WR-75G output; RJ-45 network; D-sub serial, parallel I/O and system; USB
SizeVaries by model; see the models table
WeightVaries by model; see the models table

Applications

  • High-power Ku-band teleport and broadcast uplinks
  • Multi-carrier and HTS gateway uplinks
  • Redundant and phase-combined systems

Frequently asked questions

What happens if an RF module fails?

The RF modules run in parallel through a passive waveguide combiner, so a module failure only lowers output power slightly instead of taking the uplink off air. The failed module can be hot-swapped from the front panel while the SSPA keeps transmitting, and CPI's spares kits keep a replacement on the shelf.

How do I size a ModuMAX?

Start from the link budget, then add inter-facility loss, rain-fade margin and room for future carriers. The ModuMAX's configurable power and phase-combining option let you grow later. Digisat engineers can run the numbers with you.

Need it installed, aligned or supported?

Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.