CPI's LPC, LPX and LPK low-power SSPAs deliver 25W to 50W across the C-, X- and Ku-band uplink bands in a 3.5 in high rack-mount chassis. Built with technology from CPI's ModuMAX amplifiers, their modular architecture covers the RF modules, power supplies, logic, fans and front panel, for reliable service in fixed and mobile installations.
Key features
- 25W or 50W in C-band and X-band; 25W or 35W in Ku-band
- Standard or extended C-band and Ku-band versions
- 70 dB min., 75 dB max. gain; 20 dB digital adjustment
- Forward power monitoring; RF output sample port
- RS-232/-422/-485 serial and 10Base-T network (SNMP)
- Integral 1:1 redundancy control; RCP-2001 remote panel accessory
- 100–240 VAC, power factor corrected; 3.5 in high, 19 in rack chassis
CPI LPC, LPX and LPK Low-Power Rack-Mount SSPA products
All 6 models
| Part number | band | Psat (W) | P1dB min. (W) | Power consumption |
|---|---|---|---|---|
| LPCD6050R / LPCM6050R | C-Band | 50 | 45 | 275W typ., 375W max. |
| LPCD6025R / LPCM6025R | C-Band | 25 | 22 | 225W typ., 325W max. |
| LPXB8050R | X-Band | 50 | 45 | 325W typ., 400W max. |
| LPXB8025R | X-Band | 25 | 22 | 250W typ., 350W max. |
| LPKO14035R / LPKM14035R | Ku-Band | 35 | 28 | 300W typ., 350W max. |
| LPKO14025R / LPKM14025R | Ku-Band | 25 | 20 | 275W typ., 325W max. |
Specifications
| Frequency range | Varies by model; see the models table |
|---|---|
| Saturated power | Varies by model; see the models table |
| Output P1dB | Varies by model; see the models table |
| Gain at maximum setting | 70 dB min., 75 dB max. |
| Gain vs. temperature (0–50 °C) | ±0.75 dB max., ±0.5 dB typ. |
| Gain adjustment | 20 dB min., digital, 0.1 dB steps |
| Gain flatness | ±0.75 dB full band; ±0.30 dB per 40 MHz |
| Two-tone IMD | -25 dBc max., -30 dBc typ. at 3 dB total backoff from P1dB |
| Noise figure | 8 dB typ. at max. gain |
| Residual noise | Varies by model; see the models table |
| Group delay | 0.03 ns/MHz linear, 0.003 ns/MHz² parabolic, 1.0 ns p-p ripple |
| AM/PM conversion | 2.5°/dB typ., 3.5°/dB at P1dB |
| Second harmonic / spurious | -60 dBc typ. / -70 dBc max. in band, at P1dB |
| VSWR | Input 1.2:1 typ., 1.3:1 max.; output 1.3:1 typ., 1.5:1 max. |
| Output sample port | -40 dB typ. |
| Connectors | Varies by model; see the models table |
| AC input | 100–240 VAC, 47–63 Hz, power factor corrected (0.99 typ.) |
| Power consumption | Varies by model; see the models table |
| Operating temperature | 0 °C to +50 °C inlet air; altitude to 10,000 ft, derate 2 °C per 1000 ft |
| Dimensions | 3.5 H × 19 W × 22 D in (89 × 483 × 559 mm) |
Applications
- Small earth stations and VSAT hubs
- Fixed installations and mobile terminals
- Commercial, government and military systems
Frequently asked questions
Can I set these up as a 1:1 or 1:2 redundant system?
Yes. Each SSPA has integral 1:1 redundancy control, and CPI builds 1:1 and 1:2 redundant systems around them. The RCP-2001 remote panel adds control from another location. Digisat can supply, install and commission the complete system.
How much power does it draw?
Between 225W and 325W typically depending on band and power level, and no more than 400W at a -40 °C cold start in saturation. It runs on any 100–240 VAC supply.
Need it installed, aligned or supported?
Digisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. Request installation or engineering support.