{"title":"CPI BRC-1000 Series C-Band Redundant LNB System","description":null,"products":[{"product_id":"cpi-brc-1100","title":"CPI BRC-1100 1:1 C-Band Redundant LNB System, 3.40–4.20 GHz","description":"\u003cp\u003eThe CPI BRC-1100 is a 1:1 redundant LNB system from CPI's BRC-1000 Series for C-Band earth stations. It protects one receive chain: an online LNB and a hot spare share an outdoor switch plate at the antenna hub, and the indoor controller switches to the spare automatically if the online LNB fails.\u003c\/p\u003e\u003cp\u003eThe plate takes Norsat C-band PLL or externally referenced LNBs (5.15 GHz LO, 950–1750 MHz IF), ordered separately, on a CPR-229G waveguide input. Options include waveguide input isolators, Tx reject filters, 40 dB input crossguide couplers, offline LNB I\/O ports, a remote control panel and ±48 VDC power.\u003c\/p\u003e\u003cp\u003eOrder the plate and controller as BRC-1100 and specify the Norsat C-band LNBs separately; Digisat can quote both together. The BRC-1000 Series comes in 2 listed models; compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther models in this series\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/cpi-brc-1200\"\u003eBRC-1200\u003c\/a\u003e: 1:2 system\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/cpi-brc-1000-series-c-band-redundant-lnb-system\"\u003eCompare all 2 CPI BRC-1000 Series C-Band Redundant LNB System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eBRC-1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eCPI BRC-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput frequency\u003c\/th\u003e\n\u003ctd\u003e3.40–4.20 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e950–1750 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO frequency\u003c\/th\u003e\n\u003ctd\u003e5.15 GHz typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLNBs\u003c\/th\u003e\n\u003ctd\u003eNorsat C-band PLL or externally referenced LNBs, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExternal reference (externally referenced LNBs)\u003c\/th\u003e\n\u003ctd\u003e10 MHz, -5 to +5 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdded system noise temperature (typ.)\u003c\/th\u003e\n\u003ctd\u003e7 K standard; add 1 K with couplers, 8 K with Tx reject filters, 14 K with waveguide isolators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain\u003c\/th\u003e\n\u003ctd\u003e59 dB min., 61 dB typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness\u003c\/th\u003e\n\u003ctd\u003e±0.5 dB per 27 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain stability\u003c\/th\u003e\n\u003ctd\u003e±0.2 dB max. per day at constant temperature; -0.05 dB per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e2.20:1 typ. without isolators; 1.25:1 typ., 1.30:1 max. with isolators; 1.30:1 typ., 1.35:1 max. with isolators and Tx filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.50:1 typ., 2.00:1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput P1dB\u003c\/th\u003e\n\u003ctd\u003e+2 dBm min. (+5 dBm typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput IP3\u003c\/th\u003e\n\u003ctd\u003e+12 dBm min. (+15 dBm typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency stability\u003c\/th\u003e\n\u003ctd\u003e±10 kHz, -40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise (typ.)\u003c\/th\u003e\n\u003ctd\u003e-55 \/ -75 \/ -85 \/ -95 dBc\/Hz (100 Hz \/ 1 kHz \/ 10 kHz \/ 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. input power (no damage)\u003c\/th\u003e\n\u003ctd\u003e0 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesensitization threshold, Tx band\u003c\/th\u003e\n\u003ctd\u003e-10 dBm max. without Tx filters; +45 dBm max. with Tx filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eCPR-229G waveguide flange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output and offline out\u003c\/th\u003e\n\u003ctd\u003eType F female (75 Ω) or Type N female (50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOffline in, coupler in\u003c\/th\u003e\n\u003ctd\u003eType N female (50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePlate operating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController\u003c\/th\u003e\n\u003ctd\u003e1RU, 19 in rack mount; dual redundant power supplies; universal AC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003e10\/100Base-T Ethernet (SNMP v1\/v2c\/v3), RS-232\/422\/485 serial, parallel I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eCPI notes that commercial C-band LNBs may measure up to 10 K above their stated noise temperature, so system noise depends on the LNBs fitted.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=CPI%20BRC-1100%201%3A1%20C-Band%20Redundant%20LNB%20System\u0026amp;mpn=BRC-1100\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"CPI","offers":[{"title":"Default Title","offer_id":67964365668719,"sku":"CPI-BRC-1100","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/cpi-785-11403-n-1600x1356.jpg?v=1793925976"},{"product_id":"cpi-brc-1200","title":"CPI BRC-1200 1:2 C-Band Redundant LNB System, 3.40–4.20 GHz","description":"\u003cp\u003eThe CPI BRC-1200 is a 1:2 redundant LNB system from CPI's BRC-1000 Series for C-Band earth stations. It protects two receive chains, typically both polarizations of a dual-pol feed, with one shared spare LNB. If either online LNB fails, the indoor controller switches the spare into that chain automatically.\u003c\/p\u003e\u003cp\u003eThe plate takes Norsat C-band PLL or externally referenced LNBs (5.15 GHz LO, 950–1750 MHz IF), ordered separately, on a CPR-229G waveguide input. Options include waveguide input isolators, Tx reject filters, 40 dB input crossguide couplers, offline LNB I\/O ports, a remote control panel and ±48 VDC power.\u003c\/p\u003e\u003cp\u003eOrder the plate and controller as BRC-1200 and specify the Norsat C-band LNBs separately; Digisat can quote both together. The BRC-1000 Series comes in 2 listed models; compare them on the series page.\u003c\/p\u003e\u003ch3\u003eOther models in this series\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/cpi-brc-1100\"\u003eBRC-1100\u003c\/a\u003e: 1:1 system\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/collections\/cpi-brc-1000-series-c-band-redundant-lnb-system\"\u003eCompare all 2 CPI BRC-1000 Series C-Band Redundant LNB System models\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eBRC-1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eCPI BRC-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput frequency\u003c\/th\u003e\n\u003ctd\u003e3.40–4.20 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e950–1750 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLO frequency\u003c\/th\u003e\n\u003ctd\u003e5.15 GHz typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLNBs\u003c\/th\u003e\n\u003ctd\u003eNorsat C-band PLL or externally referenced LNBs, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExternal reference (externally referenced LNBs)\u003c\/th\u003e\n\u003ctd\u003e10 MHz, -5 to +5 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdded system noise temperature (typ.)\u003c\/th\u003e\n\u003ctd\u003ePol. 1 \/ pol. 2 \/ standby: 7 \/ 8.5 \/ 10 K standard; add 1 K with couplers, 8 K with Tx reject filters, 14 K with waveguide isolators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain\u003c\/th\u003e\n\u003ctd\u003e59 dB min., 61 dB typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain flatness\u003c\/th\u003e\n\u003ctd\u003e±0.5 dB per 27 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGain stability\u003c\/th\u003e\n\u003ctd\u003e±0.2 dB max. per day at constant temperature; -0.05 dB per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput VSWR\u003c\/th\u003e\n\u003ctd\u003e2.20:1 typ. without isolators; 1.25:1 typ., 1.30:1 max. with isolators; 1.30:1 typ., 1.35:1 max. with isolators and Tx filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput VSWR\u003c\/th\u003e\n\u003ctd\u003e1.50:1 typ., 2.00:1 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput P1dB\u003c\/th\u003e\n\u003ctd\u003e+2 dBm min. (+5 dBm typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput IP3\u003c\/th\u003e\n\u003ctd\u003e+12 dBm min. (+15 dBm typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency stability\u003c\/th\u003e\n\u003ctd\u003e±10 kHz, -40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise (typ.)\u003c\/th\u003e\n\u003ctd\u003e-55 \/ -75 \/ -85 \/ -95 dBc\/Hz (100 Hz \/ 1 kHz \/ 10 kHz \/ 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. input power (no damage)\u003c\/th\u003e\n\u003ctd\u003e0 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesensitization threshold, Tx band\u003c\/th\u003e\n\u003ctd\u003e-10 dBm max. without Tx filters; +45 dBm max. with Tx filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF input\u003c\/th\u003e\n\u003ctd\u003eCPR-229G waveguide flange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output and offline out\u003c\/th\u003e\n\u003ctd\u003eType F female (75 Ω) or Type N female (50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOffline in, coupler in\u003c\/th\u003e\n\u003ctd\u003eType N female (50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePlate operating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController\u003c\/th\u003e\n\u003ctd\u003e1RU, 19 in rack mount; dual redundant power supplies; universal AC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController M\u0026amp;C\u003c\/th\u003e\n\u003ctd\u003e10\/100Base-T Ethernet (SNMP v1\/v2c\/v3), RS-232\/422\/485 serial, parallel I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eCPI notes that commercial C-band LNBs may measure up to 10 K above their stated noise temperature, so system noise depends on the LNBs fitted.\u003c\/p\u003e\u003ch3\u003eNeed it installed, aligned or supported?\u003c\/h3\u003e\u003cp\u003eDigisat engineers install, commission and maintain satellite ground systems for government agencies, teleports and broadcasters worldwide. \u003ca href=\"\/pages\/request-a-quote?service=1\u0026amp;product=CPI%20BRC-1200%201%3A2%20C-Band%20Redundant%20LNB%20System\u0026amp;mpn=BRC-1200\"\u003eRequest installation or engineering support\u003c\/a\u003e.\u003c\/p\u003e","brand":"CPI","offers":[{"title":"Default Title","offer_id":67964365734255,"sku":"CPI-BRC-1200","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/0528\/1135\/files\/cpi-785-11403-n-1600x1356.jpg?v=1793925976"}],"url":"https:\/\/digisat.org\/collections\/cpi-brc-1000-series-c-band-redundant-lnb-system.oembed","provider":"Digisat International","version":"1.0","type":"link"}